{"product_id":"carrier-ph13na048000abaa-control-board-15t5bk","title":"OEM Carrier Defrost Control Board HK32EA007 for PH13NA048000ABAA","description":"\u003ch1\u003eOEM Carrier Defrost Control Board HK32EA007 for Model PH13NA048000ABAA\u003c\/h1\u003e\u003cp\u003eThis is the genuine OEM defrost control board (part number \u003cstrong\u003eHK32EA007\u003c\/strong\u003e) factory-specified for the \u003cstrong\u003eCarrier PH13NA048000ABAA\u003c\/strong\u003e heat pump. The defrost control board monitors outdoor coil temperature and time intervals to initiate and terminate the defrost cycle. When this board fails, you'll typically see the outdoor unit accumulating heavy ice or frost, the system failing to defrost, short-cycling due to a locked-out coil, or a complete loss of heating capacity in cold weather — all signs that the defrost logic has stopped functioning correctly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM part number HK32EA007 | Replaces superseded cross-references 1173636 and 1177927 | 24V control circuit compatible | Factory-programmed defrost timing and temperature logic for Carrier heat pump systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM boards ship with factory-calibrated defrost parameters and original connector harness compatibility. Aftermarket boards frequently exhibit incorrect defrost timing intervals and premature relay failure, risking compressor damage from sustained ice buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Disconnect power at the breaker before beginning. Tools needed: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, phone or camera to photograph all wiring connections before removal. Transfer wires one at a time to avoid miswiring the reversing valve or defrost thermostat terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM manufacturer warranty. In-stock units ship same business day from our warehouse when ordered before cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003ePH13NA048000ABAA\u003c\/strong\u003e 4-ton single-stage heat pump. Verify your existing board's part number against HK32EA007 printed on the board label before ordering. Cross-references include legacy part numbers 1173636 and 1177927. If you need fitment confirmation, our team is available to verify compatibility before you purchase — ensuring you get the right board the first time.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62641932599667,"sku":"CARRIE-PH13NA048000ABAA-CONTROL_BOARD-HK32EA007","price":315.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62641932632435,"sku":"CARRIE-PH13NA048000ABAA-CONTROL_BOARD-HK32EA007-GEN","price":277.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-HK32EA007_93c2aea4-8652-4bcb-b972-acbe44db42b6.jpg?v=1775026856","url":"https:\/\/nationalhvacparts.com\/products\/carrier-ph13na048000abaa-control-board-15t5bk","provider":"National HVAC Parts","version":"1.0","type":"link"}