{"product_id":"carrier-pg96vat42060bbaa-igniter-d266ml","title":"OEM Carrier Hot Surface Igniter LH33ZG001 for PG96VAT42060BBAA","description":"\u003ch1\u003eOEM Carrier Hot Surface Igniter LH33ZG001 for Model PG96VAT42060BBAA\u003c\/h1\u003e\u003cp\u003eThis is the factory OEM hot surface igniter (part number \u003cstrong\u003eLH33ZG001\u003c\/strong\u003e) for the \u003cstrong\u003eCarrier PG96VAT42060BBAA\u003c\/strong\u003e 96% AFUE packaged gas unit. The hot surface igniter is the first component activated during every heating cycle — the control board energizes it to glow at temperatures exceeding 1,800°F, which then lights the gas burner. When the igniter fails, the furnace will attempt ignition, fail to establish flame, and enter a hard lockout — leaving you with no heat. A cracked, contaminated, or open-circuit igniter is one of the most common causes of no-heat service calls on this platform.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 120V hot surface igniter | Silicon nitride element | Includes bracket and wiring harness | Factory-matched resistance tolerances for Carrier PG96VAT42060BBAA control board timing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM igniters are manufactured to exact resistance and warm-up timing specs required by the Carrier integrated furnace control (IFC). Off-brand igniters can have inconsistent warm-up times, causing nuisance lockouts or premature failure within one season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — De-energize and lock out the unit before beginning. Allow the igniter to cool fully if the system recently ran. Tools needed: 1\/4\" hex driver, needle-nose pliers. Avoid touching the ceramic igniter element with bare hands — skin oils cause hot spots and crack the element. Photograph harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered as a direct OEM replacement for the \u003cstrong\u003eCarrier PG96VAT42060BBAA\u003c\/strong\u003e packaged gas unit. Confirm part number LH33ZG001 on your unit's parts list or data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — contact us before placing your order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62642484052339,"sku":"CARRIE-PG96VAT42060BBAA-IGNITER-LH33ZG001","price":63.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62642484085107,"sku":"CARRIE-PG96VAT42060BBAA-IGNITER-LH33ZG001-GEN","price":56.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-LH33ZG001_82b1beff-0c15-460d-9c26-d71de2ee2c05.jpg?v=1775035728","url":"https:\/\/nationalhvacparts.com\/products\/carrier-pg96vat42060bbaa-igniter-d266ml","provider":"National HVAC Parts","version":"1.0","type":"link"}