{"product_id":"carrier-pg8jaa060155aaja-flame-sensor-1xaj5m","title":"OEM Carrier Flame Sensor w\/ Wire LH680014 for PG8JAA060155AAJA","description":"\u003ch1\u003eOEM Carrier Flame Sensor with Wire LH680014 for Model PG8JAA060155AAJA\u003c\/h1\u003e\u003cp\u003eThis is the factory OEM flame sensor with wire harness for the \u003cstrong\u003eCarrier PG8JAA060155AAJA\u003c\/strong\u003e gas furnace. The flame sensor is a critical safety component — its ceramic-mounted rod generates a small microamp DC signal when immersed in the burner flame, proving to the integrated furnace control (IFC) board that combustion is occurring. When the sensor becomes coated with oxidation or carbon, or when the rod cracks, the IFC board can no longer verify a flame and will cut gas flow — typically within 5–8 seconds of ignition — causing the frustrating symptom of a furnace that lights, then immediately shuts off and enters lockout.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM Part No. \u003cstrong\u003eLH680014\u003c\/strong\u003e | Includes pre-attached wire harness | Ceramic insulator mount | Factory-matched microamp output for Carrier IFC boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is the exact factory-specified sensor with the correct rod geometry, insulator rating, and wire length. Aftermarket sensors may have mismatched rod positioning or undersized insulators, leading to nuisance lockouts or premature failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Turn off gas supply and 120V power before starting. Tools needed: 1\/4\" hex driver or nut driver, needle-nose pliers. Disconnect the existing harness connector, remove the single mounting screw, swap the sensor, reconnect the harness, and test-fire. No soldering required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for the \u003cstrong\u003eCarrier PG8JAA060155AAJA\u003c\/strong\u003e gas furnace. Always confirm the OEM part number \u003cstrong\u003eLH680014\u003c\/strong\u003e on your existing sensor or equipment data plate before ordering. Our fitment team is available to verify compatibility before you buy — ships same business day when ordered before 3 PM.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62643129876851,"sku":"CARRIE-PG8JAA060155AAJA-FLAME_SENSOR-LH680014","price":34.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62643129909619,"sku":"CARRIE-PG8JAA060155AAJA-FLAME_SENSOR-LH680014-GEN","price":30.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flame-sensor-LH680014_da6a9ee9-44af-4449-860e-69bb9f95d523.jpg?v=1775031219","url":"https:\/\/nationalhvacparts.com\/products\/carrier-pg8jaa060155aaja-flame-sensor-1xaj5m","provider":"National HVAC Parts","version":"1.0","type":"link"}