{"product_id":"carrier-n6d48ng480100-pressure-switch-h43sg3","title":"OEM Carrier Pressure Switch HK06WC061 for N6D48NG480100","description":"\u003ch1\u003eOEM Carrier Pressure Switch HK06WC061 for Model N6D48NG480100\u003c\/h1\u003e\u003cp\u003eThis is the factory OEM replacement pressure switch (part number \u003cstrong\u003eHK06WC061\u003c\/strong\u003e) for the \u003cstrong\u003eCarrier N6D48NG480100\u003c\/strong\u003e packaged gas unit. The pressure switch is a critical safety device that monitors the negative pressure (measured in inches of water column, W.C.) created by the inducer draft motor before the control board allows ignition to proceed. If the switch fails to close — or sticks open — the furnace or packaged unit will lock out before the ignition sequence ever begins, leaving you with a no-heat condition. Common symptoms include a blinking fault code indicating a pressure switch error, the inducer running continuously without ignition, or the system recycling repeatedly without producing heat.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM part number HK06WC061 | Factory-calibrated W.C. (water column) rating | Single-port or dual-port configuration matched to N6D48NG480100 inducer assembly | Direct plug-and-play connector fit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM pressure switches are calibrated to exact W.C. tolerances required by the Carrier N6D48NG480100 control board. Off-brand substitutes often carry wider tolerances, risking nuisance lockouts or, worse, allowing ignition under unsafe draft conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Shut off power and gas before beginning. Tools needed: 1\/4\" nut driver, flathead screwdriver, and a manometer for verification. Disconnect the rubber hose and wiring harness, swap the switch, and confirm hose integrity for no cracks or blockages before restoring power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered specifically for the Carrier \u003cstrong\u003eN6D48NG480100\u003c\/strong\u003e packaged gas unit. Always verify your existing part number printed on the switch body against HK06WC061 before ordering. If you have any fitment questions, our HVAC parts specialists are available to confirm compatibility before you purchase — ensuring you get the right part the first time.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909267542387,"sku":"CARRIE-N6D48NG480100-PRESSURE_SWITCH-HK06WC061","price":27.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909267575155,"sku":"CARRIE-N6D48NG480100-PRESSURE_SWITCH-HK06WC061-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK06WC061_315c2497-4acf-46cd-abe5-3a4792a5105e.jpg?v=1782930852","url":"https:\/\/nationalhvacparts.com\/products\/carrier-n6d48ng480100-pressure-switch-h43sg3","provider":"National HVAC Parts","version":"1.0","type":"link"}