{"product_id":"carrier-n6a48ng481457-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481457","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481457\u003c\/h1\u003e\u003cp\u003eThis is the OEM-specified run capacitor for the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6A48NG481457\u003c\/strong\u003e gas furnace. The draft inducer motor capacitor provides the precise starting torque and continuous run support required to spin the inducer blower — the component that purges combustion gases before and during each heating cycle. When this capacitor fails, the inducer motor will hum without spinning, run sluggishly, or fail to prove sufficient negative pressure to close the pressure switch, resulting in a no-heat lockout condition. Referenced under OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor) and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor w\/ Capacitor), this capacitor is the factory-matched replacement to restore full inducer performance without replacing the entire motor assembly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched MFD and voltage rating | Factory tolerance ±3% | Designed for inducer motor run-circuit duty | Replaces capacitor component within assemblies 50HE400792 and HC30CL461\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are wound to exact factory MFD tolerances, protecting the inducer motor bearings and windings from the stress of under- or over-capacitance. Generic alternatives often run ±10% tolerance, which can shorten inducer motor life and cause nuisance pressure switch faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Disconnect power and verify zero voltage before handling. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always photograph existing wiring and terminal connections before removal. Discharge any residual voltage from the old capacitor prior to disconnecting leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects in materials and workmanship. Orders placed before cutoff ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the \u003cstrong\u003eCarrier N6A48NG481457\u003c\/strong\u003e gas furnace draft inducer motor circuit. Verify your existing capacitor's MFD and voltage ratings against your unit's data plate and inducer motor nameplate before ordering. Cross-references OEM part numbers 50HE400792 and HC30CL461. Have your model and serial number ready — our fitment team is available to confirm compatibility before you order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909278585203,"sku":"CARRIE-N6A48NG481457-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909278617971,"sku":"CARRIE-N6A48NG481457-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_a8f50b71-a89e-4ecf-9ab4-8459ba7147b3.jpg?v=1782914127","url":"https:\/\/nationalhvacparts.com\/products\/carrier-n6a48ng481457-capacitor-j89nd1","provider":"National HVAC Parts","version":"1.0","type":"link"}