{"product_id":"carrier-09de164c600-contactor-1h36kb","title":"OEM Carrier Contactor 2-Pole 120V 30A for 09DE164C600","description":"\u003ch1\u003eOEM Carrier 2-Pole Contactor 120V 30 Amp — HN52KC052 for Model 09DE164C600\u003c\/h1\u003e\u003cp\u003eThis is the genuine OEM Carrier contactor (part number \u003cstrong\u003eHN52KC052\u003c\/strong\u003e), factory-specified for the \u003cstrong\u003eCarrier 09DE164C600\u003c\/strong\u003e. The contactor acts as a high-voltage relay, energizing when the thermostat calls for cooling and closing the circuit to the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a welded\/stuck plunger, or a burned coil — your system will either fail to start entirely, run continuously without shutting off, or produce an audible buzzing or chattering sound from the electrical panel or disconnect box.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 2-Pole | 120V AC Coil | 30 Amp Rating | 60 Hz | Screw terminal connections | Single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Factory Authorized Part built to Carrier's exact electrical tolerances. Aftermarket contactors frequently use lower-grade contact material, leading to accelerated pitting, premature failure, and potential compressor damage from voltage drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Always disconnect power at both the breaker and the disconnect box before proceeding. Tools needed: flathead and Phillips screwdrivers, 1\/4\" nut driver, needle-nose pliers, voltage tester. Photograph all wire positions before removal. One-for-one wire transfer from old to new unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In-stock units ship same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed as the factory replacement contactor for Carrier model \u003cstrong\u003e09DE164C600\u003c\/strong\u003e. Verify your unit's coil voltage (120V) and amperage rating on the equipment data plate or existing contactor label before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — ships same day.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640104079731,"sku":"CARRIE-09DE164C600-CONTACTOR-HN52KC052","price":118.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640104112499,"sku":"CARRIE-09DE164C600-CONTACTOR-HN52KC052-GEN","price":104.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-HN52KC052_06889eef-660a-4273-802e-75ae5b143484.jpg?v=1775021661","url":"https:\/\/nationalhvacparts.com\/products\/carrier-09de164c600-contactor-1h36kb","provider":"National HVAC Parts","version":"1.0","type":"link"}