{"product_id":"carrier-09de109c100-contactor-1h36kb","title":"OEM Carrier Contactor 2-Pole 30A 120V Coil for 09DE109C100","description":"\u003ch1\u003eOEM Carrier 2-Pole 30 Amp 120V Contactor HN52KC052 for Model 09DE109C100\u003c\/h1\u003e\u003cp\u003eThis is the genuine OEM replacement contactor for the \u003cstrong\u003eCarrier 09DE109C100\u003c\/strong\u003e, factory part number \u003cstrong\u003eHN52KC052\u003c\/strong\u003e. The contactor is the high-voltage switching relay that controls power delivery to the compressor and condenser fan motor. When energized by the 120V control coil, its contacts close and allow line voltage to flow to the load side of the system. A failing contactor is one of the most common causes of HVAC no-start conditions — symptoms include the unit humming but not starting, chattering or buzzing at the contactor, pitted or burned contact points, or the system failing to shut off when commanded by the thermostat.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 2-Pole | 30 Amp FLA | 120V AC Coil | 50\/60 Hz | Factory-matched contact material and coil pull-in voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e Genuine OEM contactors meet Carrier's exact safety and performance specifications. Off-brand substitutes often use lighter contact alloys that pit and arc more quickly, reducing service life and increasing the risk of compressor damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Disconnect and lock out power before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always photograph existing wiring before removing terminals. Swap line, load, and coil wires one at a time to avoid miswiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In-stock units ship same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed as a direct OEM replacement for Carrier model \u003cstrong\u003e09DE109C100\u003c\/strong\u003e. Verify coil voltage (120V) and amperage rating on your unit's data plate before ordering. Cross-references include Bryant and Payne units sharing the HN52KC052 specification. Need help confirming fitment? Our HVAC parts specialists verify compatibility before you order — contact us today and get your part shipped fast.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640112206195,"sku":"CARRIE-09DE109C100-CONTACTOR-HN52KC052","price":109.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640112238963,"sku":"CARRIE-09DE109C100-CONTACTOR-HN52KC052-GEN","price":96.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-HN52KC052_6cc51e9d-16f3-42ee-9861-dac6af47dba1.jpg?v=1775021932","url":"https:\/\/nationalhvacparts.com\/products\/carrier-09de109c100-contactor-1h36kb","provider":"National HVAC Parts","version":"1.0","type":"link"}