{"product_id":"carrier-09de109230-contactor-1h36kb","title":"OEM Carrier 2-Pole Contactor 35A 208\/240V for 09DE109230","description":"\u003ch1\u003eOEM Carrier 2-Pole Contactor 35A 208\/240V — Model 09DE109230\u003c\/h1\u003e\u003cp\u003eThe \u003cstrong\u003eCarrier HN52KC053\u003c\/strong\u003e is the factory-specified 2-pole contactor for the \u003cstrong\u003e09DE109230\u003c\/strong\u003e unit. The contactor acts as a high-voltage relay, switching 208\/240V power to the compressor and condenser fan motor whenever the thermostat calls for cooling. When this component fails, the control board sends the 24V signal but nothing happens — the outdoor unit stays completely silent even though the indoor air handler is running. A failed or pitted contactor is one of the most common causes of a no-cool call in residential and light-commercial HVAC systems.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 2-Pole | 35 Amps | 208\/240V load voltage | 24V coil voltage | replaces OEM part number HN52KC053\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM-grade contactor matches the exact coil pull-in voltage and contact ratings specified by Carrier for the 09DE109230, ensuring reliable switching under full-load conditions. Generic substitutes often use lower-grade contact materials that pit and arc prematurely, leading to repeat failures within a single season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Always disconnect power at the disconnect box and verify zero voltage with a multimeter before touching any terminals. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring before removal. Swap wires one-at-a-time to avoid miswiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; Shipping:\u003c\/strong\u003e 1-year OEM warranty coverage. Ships same business day from our warehouse when ordered before cutoff — get your system cooling again fast.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for Carrier model \u003cstrong\u003e09DE109230\u003c\/strong\u003e. Always verify the part number on your existing contactor's label and confirm load amperage and coil voltage match before installation. Have questions about fit? Our HVAC parts specialists confirm compatibility before you order — no guesswork.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640114073971,"sku":"CARRIE-09DE109230-CONTACTOR-HN52KC053","price":65.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640114106739,"sku":"CARRIE-09DE109230-CONTACTOR-HN52KC053-GEN","price":57.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-HN52KC053_d7317ac0-2b84-44d5-a565-903234e2ada3.jpg?v=1775015580","url":"https:\/\/nationalhvacparts.com\/products\/carrier-09de109230-contactor-1h36kb","provider":"National HVAC Parts","version":"1.0","type":"link"}