{"title":"Wiring Harnesses \u0026 Wire","description":"\u003cp\u003eOEM wiring harness assemblies and thermostat wire — factory connectors, correct wire gauge and lengths, plug-and-play by model. Match your exact model number for the right harness; every listing shows fitment.\u003c\/p\u003e","products":[{"product_id":"carrier-pg8mea060135aaja-igniter-d266ml","title":"OEM Carrier Hot Surface Igniter w\/ Bracket \u0026 Harness — PG8MEA060135AAJ","description":"\u003ch1\u003eOEM Carrier Hot Surface Igniter LH33ZG001 for Model PG8MEA060135AAJA\u003c\/h1\u003e\u003cp\u003eThis is the genuine OEM hot surface igniter (part number \u003cstrong\u003eLH33ZG001\u003c\/strong\u003e) factory-specified for the \u003cstrong\u003eCarrier PG8MEA060135AAJA\u003c\/strong\u003e packaged gas heating unit. The hot surface igniter is the first component activated on every call for heat — the control board energizes it to reach ignition temperature (~2,500°F), then opens the gas valve to light the burners. When it fails, the furnace will attempt ignition, fail to light, and enter a safety lockout — leaving you with no heat. Common symptoms include the system cycling on and off repeatedly, a fault code indicating ignition failure, or the unit running the inducer motor but never producing heat.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Specs:\u003c\/strong\u003e OEM part number \u003cstrong\u003eLH33ZG001\u003c\/strong\u003e | Includes mounting bracket and wiring harness | Silicon nitride element | Factory-matched fit for Carrier PG8MEA060135AAJA — no modifications required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM igniter — not an aftermarket substitute. OEM silicon nitride elements are precision-calibrated for exact resistance and heat-up time. Generic igniters often use mismatched resistance profiles, causing intermittent lockouts or premature cracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Always de-energize the unit at the disconnect before beginning. Tools needed: 1\/4\" nut driver, Phillips screwdriver, needle-nose pliers. Critical: never touch the igniter element with bare hands — skin oils cause thermal stress fractures. Photograph wiring connections before disconnecting the harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; Shipping:\u003c\/strong\u003e 1-year OEM factory warranty against defects. In stock and ships same business day from our warehouse when ordered before cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered as the direct OEM replacement for \u003cstrong\u003eCarrier PG8MEA060135AAJA\u003c\/strong\u003e packaged gas units. Verify your existing part number on the unit's parts label or service manual before ordering. Not sure if this fits? Our HVAC parts specialists verify fitment before you buy — contact us with your model and serial number.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62642854429043,"sku":"CARRIE-PG8MEA060135AAJA-IGNITER-LH33ZG001","price":42.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62642854461811,"sku":"CARRIE-PG8MEA060135AAJA-IGNITER-LH33ZG001-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-LH33ZG001_9302c63d-80c3-46aa-8919-54e4b5efed70.jpg?v=1782926973"},{"product_id":"6-foot-ac-condenser-whip-1-2-x-6ft-liquid-tight-flexible-conduit","title":"6-Foot AC Condenser Whip — 1\/2\" x 6ft 10 AWG Liquid-Tight Flexible Conduit | National HVAC Parts","description":"\u003cp\u003e6-foot liquid-tight flexible conduit whip for connecting AC condenser units to the outdoor disconnect. Pre-wired with 10 AWG THHN conductors for 30A circuits. Required by code for outdoor AC installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 6 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1\/2\" conduit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire:\u003c\/strong\u003e 10 AWG (3-conductor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRating:\u003c\/strong\u003e 30A \/ 240V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Connect to disconnect box and condenser unit terminals. 15 min.\u003c\/p\u003e","brand":"National HVAC Parts","offers":[{"title":"Default Title","offer_id":63010586460531,"sku":"NHVAC-WHIP-6FT","price":16.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/WHIP-6FT.jpg?v=1782265093"},{"product_id":"18-5-thermostat-wire-50ft-18-gauge-5-conductor-hvac-control-cable","title":"18\/5 Thermostat Wire 50ft — 18 Gauge 5-Conductor HVAC Control Cable | National HVAC Parts","description":"\u003cp\u003e50-foot roll of 18\/5 thermostat wire (18 gauge, 5 conductors). Standard wire for connecting thermostats to HVAC systems. 5 conductors support heat, cool, fan, common, and reversing valve (heat pump systems).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGauge:\u003c\/strong\u003e 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors:\u003c\/strong\u003e 5 (R, G, Y, W, C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 50 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket:\u003c\/strong\u003e UL listed CL2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"National HVAC Parts","offers":[{"title":"Default Title","offer_id":63013405426035,"sku":"NHVAC-WIRE-TSTAT-50","price":24.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/WIRE-TSTAT-50.jpg?v=1782263455"},{"product_id":"18-8-thermostat-wire-50ft-18-gauge-8-conductor-hvac-control-cable","title":"18\/8 Thermostat Wire 50ft — 18 Gauge 8-Conductor HVAC Control Cable | National HVAC Parts","description":"\u003cp\u003e50-foot roll of 18\/8 thermostat wire. 8 conductors for complex HVAC systems with multiple stages, humidifiers, dehumidifiers, or smart thermostats requiring C-wire.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGauge:\u003c\/strong\u003e 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 50 feet\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"National HVAC Parts","offers":[{"title":"Default Title","offer_id":63013405458803,"sku":"NHVAC-WIRE-TSTAT-8","price":34.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/WIRE-TSTAT-8.jpg?v=1782263522"},{"product_id":"4-foot-ac-condenser-whip-1-2-x-4ft-liquid-tight-flexible-conduit","title":"4-Foot AC Condenser Whip — 1\/2\" x 4ft Liquid-Tight Flexible Conduit | National HVAC Parts","description":"\u003cp\u003e4-foot liquid-tight flexible conduit whip for short-run AC condenser connections. Pre-wired with 10 AWG conductors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 4 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1\/2\" conduit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire:\u003c\/strong\u003e 10 AWG (3-conductor)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"National HVAC Parts","offers":[{"title":"Default Title","offer_id":63013405491571,"sku":"NHVAC-WHIP-4FT","price":14.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/WHIP-4FT.jpg?v=1782263362"},{"product_id":"tempstar-1-4-hp-condenser-fan-motor-for-tvh825gka101-oem-with-adapter-harness-ships-today","title":"Tempstar 1\/4 HP Condenser Fan Motor for TVH825GKA101 — OEM with Adapter \u0026 Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the OEM 1\/4 HP Fan Motor (part number 1187928) for the Tempstar TVH825GKA101, supplied with its matching mounting adapter (1188001) and fan motor wiring harness (1188022). The condenser fan motor drives the outdoor fan blade that pulls air across the condenser coil to reject heat from the system. A weak or failed motor causes the unit to overheat, trip on high head pressure, or stop cooling entirely. The 1\/4 HP rating delivers the airflow this model is engineered for. Common failure symptoms include a humming motor that will not start, a fan that spins slowly or seizes, overheating that trips the breaker, or hot bearings and noisy operation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Part Number\u003c\/td\u003e\n\u003ctd\u003e1187928 (MTR FAN 1\/4 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003e1188001 (Adapter Fan Motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarness\u003c\/td\u003e\n\u003ctd\u003e1188022 (Harness Assembly Fan Motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCondenser Fan Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eTVH825GKA101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eThis 1\/4 HP motor kit is the factory replacement for the Tempstar TVH825GKA101 condenser. The included adapter and harness ensure a direct bolt-in and plug-in fit. Confirm the 1\/4 HP rating and part number 1187928 against your existing motor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser top grille and fan assembly service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all motor wiring and the fan blade position on the shaft before removing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Loosen the blade set screw, unbolt the old motor from the bracket, and disconnect the harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new motor using the adapter, transfer the blade at the same depth, and connect the harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify the fan spins freely in the correct direction at full speed.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFan motor hums but does not start or spin.\u003c\/li\u003e\n\u003cli\u003eUnit trips on high-pressure or overheats during cooling.\u003c\/li\u003e\n\u003cli\u003eLoud bearing noise, grinding, or a wobbling blade.\u003c\/li\u003e\n\u003cli\u003eMotor is hot to the touch or smells burnt.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63027259179379,"sku":"1188001-GEN","price":179.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048391852403,"sku":"1188001","price":233.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-condenser-fan-motor-1188001.jpg?v=1782957646"},{"product_id":"tempstar-1-5-hp-condenser-fan-motor-for-tvh824gka101-oem-with-adapter-harness-ships-today","title":"Tempstar 1\/5 HP Condenser Fan Motor for TVH824GKA101 — OEM with Adapter \u0026 Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the OEM 1\/5 HP Fan Motor (part number 1187927) for the Tempstar TVH824GKA101, supplied with its matching mounting adapter (1188001) and fan motor wiring harness (1188022). The condenser fan motor turns the outdoor fan blade that pulls air across the condenser coil to release heat from the refrigerant. When this motor weakens or fails, the system overheats, trips on high head pressure, or stops cooling. The 1\/5 HP rating matches the airflow this model is designed for. Common failure symptoms include a humming motor that will not start, a slow or seized fan, breaker trips from overheating, and noisy or hot bearings.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Part Number\u003c\/td\u003e\n\u003ctd\u003e1187927 (MTR FAN 1\/5 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003e1188001 (Adapter Fan Motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarness\u003c\/td\u003e\n\u003ctd\u003e1188022 (Harness Assembly Fan Motor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCondenser Fan Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eTVH824GKA101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eThis 1\/5 HP motor kit is the factory replacement for the Tempstar TVH824GKA101 condenser. The included adapter and harness provide a direct bolt-in and plug-in fit. Confirm the 1\/5 HP rating and part number 1187927 against your existing motor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser top grille and fan assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all motor wiring and the fan blade position on the shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Loosen the blade set screw, unbolt the old motor, and disconnect the harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new motor with the adapter, set the blade at the same depth, and connect the harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify the fan spins freely in the correct direction at full speed.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFan motor hums but will not start or spin.\u003c\/li\u003e\n\u003cli\u003eUnit trips on high pressure or overheats during cooling.\u003c\/li\u003e\n\u003cli\u003eGrinding, squealing, or a wobbling fan blade.\u003c\/li\u003e\n\u003cli\u003eMotor runs hot or smells burnt.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63027259212147,"sku":"1188001-GEN","price":159.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048392507763,"sku":"1188001","price":207.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-condenser-fan-motor-1188001_b1e80c37-7405-4ae9-b1ee-e9a88277ceef.jpg?v=1782957676"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150srcb0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SRCB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (part number 1171306) plus the matching igniter wiring kit (part number 1188370) lights the burners on the ICP RGS150SRCB0AAAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows white-hot to ignite gas at the burners. Hot surface igniters are brittle and degrade over thousands of cycles — common failures are a cracked element, no glow, or a furnace that locks out after several ignition attempts. The included wiring kit replaces brittle, heat-damaged leads and the connector for a clean, reliable installation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits the ICP RGS150SRCB0AAAA and equivalent Tempstar, Heil, and Comfortmaker furnaces using this hot surface igniter. Handle the new igniter by its ceramic base only — skin oils shorten element life.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and electrical power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw(s); discard the old igniter and leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then install the new wiring kit and connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the trial-for-ignition window.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo glow when the furnace calls for heat\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the ceramic element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eIntermittent ignition or delayed burner light-off\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027355222387,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691993459,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_75b96fee-4335-48eb-9e07-034e9ee26cf2.jpg?v=1782894243"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150srca0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SRCA0AAAA – With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine ICP hot surface igniter kit includes the igniter (OEM #1171306) and its matched wiring harness kit (OEM #1188370) for the RGS150SRCA0AAAA furnace. On each call for heat, the control board sends voltage to the igniter, which glows white-hot and ignites the gas at the burners. Because the igniter element is thin and brittle, it is one of the most common furnace failure points — it degrades with thermal cycling and cracks easily if touched or contaminated. The included wiring kit ensures a clean, corrosion-free connection to the harness, eliminating the intermittent no-heat faults that come from a brittle or burned igniter lead. Replacing both together is the reliable, professional repair.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter with wiring harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eIgnites burners on heat call\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM exact-fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP \/ Heil \/ Tempstar \/ Comfortmaker RGS150SRCA0AAAA furnace and related models that use this hot surface igniter and harness. Match the igniter mounting bracket and connector to your existing part before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Shut off gas at the manual shutoff and disconnect electrical power. Verify zero voltage at the igniter leads with a multimeter before working.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the burner compartment door to reach the igniter at the burner assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph the igniter position, bracket, and wiring\/connector routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Unplug the harness, unfasten the igniter bracket screw, and carefully withdraw the old igniter — never touch the new element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new igniter in the same position, install the new wiring kit, and seat the connector fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light within the normal trial-for-ignition window.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs but burners never light (no heat)\u003c\/li\u003e\n\u003cli\u003eVisible crack, blistering, or breakage in the igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all on a heat call\u003c\/li\u003e\n\u003cli\u003eIntermittent ignition lockouts or repeated retry cycling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027356402035,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691960691,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_f83e1545-247b-41ee-a58b-be5c526b454d.jpg?v=1782894241"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150sraa0agaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SRAA0AGAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (part 1171306) is the ceramic element that ignites the burners on your ICP \/ Tempstar \/ Heil RGS150SRAA0AGAA gas furnace. On each call for heat, 120V is applied to the igniter, which glows red-hot and lights the gas at the first burner. The included wiring kit (part 1188370) provides the correct OEM harness and connector so the new igniter plugs in cleanly. Hot surface igniters are brittle and degrade over time; a cracked element or one that no longer glows is a leading cause of no-heat calls and short-cycling lockouts on furnace control boards.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter) + 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter Wiring Kit \/ Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP \/ Tempstar \/ Heil RGS150SRAA0AGAA and related gas furnaces that use a 120V hot surface igniter with this OEM mounting and harness. The included wiring kit ensures a correct, plug-and-play connection.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harness and remove the mounting screw; handle the old igniter by its bracket only, never the ceramic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then connect the supplied wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace blower runs but burners never light (no heat).\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow on a call for heat.\u003c\/li\u003e\n\u003cli\u003eVisible cracks or chips in the ceramic element.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027357548915,"sku":"1171306","price":54.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691927923,"sku":"1171306-GEN","price":42.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_b4128c0f-6362-41e5-9fc0-138d2d07c248.jpg?v=1782894239"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150sfba0agaa-includes-igniter-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SFBA0AGAA — Includes Igniter Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter assembly is the direct ignition source for the ICP\/Tempstar\/Heil RGS150SFBA0AGAA gas furnace. The igniter (OEM 1171306) glows to a high temperature on each call for heat to light the main burners, while the included igniter wiring kit (OEM 1188370) replaces the brittle, heat-fatigued harness that connects it to the control board. A failed or cracked igniter is one of the most common causes of no-heat calls: the element develops hairline fractures, loses continuity, and the furnace locks out after several failed ignition attempts. Replacing the igniter together with its wiring kit restores reliable, single-try ignition and prevents repeat callbacks from a marginal connector.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number (Igniter)\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number (Wiring Kit)\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Direct Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS150SFBA0AGAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the ICP-family RGS150SFBA0AGAA furnace and the closely related Tempstar, Heil, and Comfortmaker variants that share the same ignition platform. Always confirm your existing igniter's part number and connector before ordering. This is the OEM-specified replacement, not a universal substitute.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting position and the wiring harness routing before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw(s), and lift the old igniter out by its ceramic base — never touch the element. Cut or unplug the old harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter in the exact original position so the element sits in the burner flame path, then connect the new wiring kit per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power and watch a full ignition cycle: the igniter should glow bright and light the burners on the first try.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks and tries to light but never ignites, then locks out.\u003c\/li\u003e\n\u003cli\u003eIgniter shows visible cracks, blisters, or no longer glows.\u003c\/li\u003e\n\u003cli\u003eRepeated ignition retries before the burners finally catch.\u003c\/li\u003e\n\u003cli\u003eMelted, discolored, or loose igniter connector and harness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027360268659,"sku":"1171306","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691862387,"sku":"1171306-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_90914050-a1c8-473e-959d-4b17bbcdcb2f.jpg?v=1782894234"},{"product_id":"icp-hot-surface-igniter-kit-with-wiring-harness-for-rgs150secb0aaaa-oem-fit-ships-today","title":"ICP Hot Surface Igniter Kit with Wiring Harness for RGS150SECB0AAAA — OEM Fit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM ignition kit includes the hot surface igniter (part 1171306) and the matching igniter wiring kit (part 1188370) for your ICP Tempstar\/Heil RGS150SECB0AAAA gas unit. On a heating call, the control board energizes the hot surface igniter, which glows red-hot to ignite the gas as it leaves the burner. The included wiring kit replaces the high-temperature igniter leads and connector that degrade over time from repeated heat cycling. Hot surface igniters are brittle and one of the most common no-heat failures — they crack from thermal stress, age out, or develop high resistance. Replacing the igniter together with fresh wiring restores reliable ignition and eliminates intermittent connector faults.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter with wiring harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eGas burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace \/ gas-electric package unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP\/Tempstar\/Heil RGS150SECB0AAAA and related RGS-series gas units that use this hot surface igniter and wiring kit. Confirm the igniter mounting and connector match your existing assembly before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off the gas supply, disconnect power, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner\/service compartment panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the old igniter harness and unfasten the cracked or failed igniter (handle by the ceramic base only — never touch the element).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter at the correct burner position, connect the new wiring kit, and route leads away from heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light reliably.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo heat \/ furnace fails to ignite\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weakly\u003c\/li\u003e\n\u003cli\u003eVisibly cracked or broken igniter element\u003c\/li\u003e\n\u003cli\u003eIntermittent ignition or repeated lockouts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027365380467,"sku":"1171306","price":51.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047694844275,"sku":"1171306-GEN","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_af21b48d-ac88-4a2d-b410-6936961dfe0e.jpg?v=1782894425"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150seca0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SECA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter kit for the ICP \/ Tempstar \/ Heil RGS150SECA0AAAA gas furnace includes the igniter element (part number 1171306) and its matching wiring harness kit (part number 1188370). On a call for heat, the furnace control board sends line voltage to the igniter, which glows white-hot to ignite the gas burners. Igniters are brittle silicon-carbide or silicon-nitride elements that degrade with every heating cycle and eventually crack or burn out. When the igniter fails, the furnace will go through its pre-purge and gas valve sequence but never light, often locking out after three failed trials. Including the wiring kit ensures the connector and leads — common secondary failure points from heat fatigue — are replaced at the same time.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP \/ Tempstar \/ Heil RGS150SECA0AAAA furnace and related ICP-family models that originally used igniter 1171306. Always match the igniter mounting bracket and connector style to your existing part.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect electrical power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/control access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw; handle the old igniter only by its ceramic base — never touch the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter (touching only the base), install the new wiring kit, and reconnect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and confirm the igniter glows and burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace sequences but burners never ignite\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the igniter element\u003c\/li\u003e\n\u003cli\u003eNo glow when the control calls for heat\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts (3 flashes\/trial faults)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027366297971,"sku":"1171306","price":49.4,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691764083,"sku":"1171306-GEN","price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_146c4865-1e21-4100-8877-e7791ecbe444.jpg?v=1782894228"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150seba0agaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SEBA0AGAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM hot surface igniter (part 1171306) paired with its dedicated igniter wiring kit (part 1188370) for the ICP \/ Tempstar \/ Heil RGS150SEBA0AGAA gas unit. On each call for heat the control board energizes the igniter, which heats to a glowing temperature and lights the burner gas. The wiring kit supplies the correct connector, leads, and ceramic-rated terminals to power the igniter safely. Hot surface igniters are brittle and degrade with every heating cycle; the silicon-carbide or silicon-nitride element eventually cracks, thins, or simply fails to reach ignition temperature. When the igniter fails, the furnace runs its sequence but never lights — leading to no heat and lockout. Replacing the igniter together with a fresh wiring kit eliminates intermittent connector and lead failures that can mimic a bad igniter.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element and igniter wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBurner ignition on call for heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS150SEBA0AGAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the ICP \/ Tempstar \/ Heil RGS150SEBA0AGAA and related RGS150 platform units using the same hot surface ignition system. Confirm your full model and serial number before ordering.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power. Verify zero voltage with a multimeter before working in the burner compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner\/ignition access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring connector before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harness, remove the igniter mounting screw, and carefully withdraw the brittle igniter — never touch the element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1171306 igniter, install the 1188370 wiring kit, and seat the connector fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the normal sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace runs the ignition sequence but burners never light\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts and no-heat calls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027366953331,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691698547,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_48a7356e-f8c7-45b4-970a-292a9f8b3630.jpg?v=1782894225"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150seba0aaaa-oem-ignitor-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SEBA0AAAA — OEM Ignitor + Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM Hot Surface Igniter Kit pairs the igniter (part number 1171306) with its matching wiring harness kit (part number 1188370) for the ICP \/ Tempstar \/ Heil RGS150SEBA0AAAA gas-electric package unit. On a heat call, the control board sends voltage to the igniter, which glows red-hot and lights the burners. Hot surface igniters are brittle and degrade with every heating cycle — hairline cracks and erosion eventually cause an open circuit and no heat. The included wiring kit ensures clean, factory-spec terminations so the igniter receives correct voltage. Installing the complete OEM kit restores reliable first-try ignition and prevents nuisance lockouts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM exact replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace \/ rooftop package unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement ignition kit for the ICP Tempstar Heil RGS150SEBA0AAAA package unit. The igniter (1171306) and wiring kit (1188370) are matched to this model's ignition circuit and mounting. Confirm your existing igniter part number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect electrical power and shut off the gas. Verify zero voltage with a multimeter before proceeding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner\/ignition access panel to expose the igniter and its harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting position, bracket orientation, and wiring connection before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the harness plug and remove the igniter mounting screw(s). Handle the old igniter by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the silicon element, install the new wiring kit, and reconnect per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and confirm the igniter glows and lights the burners on the first attempt.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat — igniter never glows on a heat call\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or white\/eroded spots on the element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003cli\u003eIgniter glows but burners fail to light, or harness is brittle\/burned\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027367903603,"sku":"1171306","price":57.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691665779,"sku":"1171306-GEN","price":44.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_e9579d7e-c7d1-4d97-ac0b-af8bd8c3cf1a.jpg?v=1782894223"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150seaa0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150SEAA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit is the factory ignition source for the ICP \/ Tempstar \/ Heil RGS150SEAA0AAAA gas furnace. The igniter (OEM 1171306) is a silicon-carbide hot surface element that glows red-hot when energized by the 120V ignition circuit, lighting the burners on each call for heat. The included wiring kit (OEM 1188370) supplies the matched pigtail harness and connector so the igniter mates cleanly to the control board without splicing. A failed igniter is one of the most common no-heat causes on these furnaces — the brittle element cracks from thermal cycling or carbon fouling and stops glowing, so the burners never light and the board locks out.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM, direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP \/ Tempstar \/ Heil RGS150SEAA0AAAA gas furnace and shares the same ignition platform as many RGS-series and comparable Heil\/Tempstar\/Comfortmaker single-stage gas furnaces of this generation. Always confirm against your unit's model and serial tag before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, and close the gas shutoff. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower\/burner service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter bracket and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness at the control board, remove the igniter mounting screw, and lift the old element out — handle only by the ceramic base, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new igniter in the burner assembly, secure the screw, and connect the new wiring kit to the board per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the normal ignition sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs but the burners never light (no-heat call).\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows orange\/red during the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or white\/gray carbon buildup on the element.\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout fault code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027372392819,"sku":"1171306","price":48.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691633011,"sku":"1171306-GEN","price":36.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_f5cdfffd-dc3a-47bb-a107-46a7e331ab76.jpg?v=1782894221"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150lsaa0agaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LSAA0AGAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (part 1171306) with matching wiring kit (part 1188370) provides reliable ignition for the gas burners in your ICP RGS150LSAA0AGAA furnace. On a heat call the control board sends 120V to the igniter element, which glows to roughly 2,000°F and lights the gas as the valve opens. Igniters are a wear item — the brittle silicon-carbide or silicon-nitride element develops hairline cracks from thermal cycling and eventually fails to glow, leaving you with no heat. The included wiring kit ensures a clean, corrosion-free connection.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil RGS150LSAA0AGAA gas furnace and related Comfortmaker and Day \u0026amp; Night models using the same hot surface ignition assembly. Confirm the mounting bracket and connector match the original.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power, verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and remove the mounting screw; handle the old element by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then connect the new wiring kit per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blows cold air — no ignition on a heat call\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weakly\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the element\u003c\/li\u003e\n\u003cli\u003eRepeated lockouts after several ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027379077491,"sku":"1171306","price":46.8,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691501939,"sku":"1171306-GEN","price":36.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_d38d33ec-ca2c-42d6-aa37-10e07b28b2da.jpg?v=1782894212"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150lrcb0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LRCB0AAAA — with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (OEM #1171306) with its matching wiring kit (OEM #1188370) is the component that lights the burners in your ICP \/ Tempstar \/ Heil RGS150LRCB0AAAA furnace. On a call for heat, the control board powers the igniter, which glows red-hot to ignite the gas. Igniters are brittle and degrade over time — common failure symptoms include no ignition, a furnace that cycles on the gas valve without lighting, a cracked or visibly fractured element, or a unit that locks out after several failed ignition attempts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Ignitor), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the ICP \/ Tempstar \/ Heil RGS150LRCB0AAAA gas furnace. The included wiring kit ensures a clean, correct connection to the furnace control board.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and remove the mounting screw; handle the old element by its ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter (never touch the element with bare fingers), install the wiring kit, and reconnect to the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace does not ignite on a call for heat\u003c\/li\u003e\n\u003cli\u003eIgniter element is cracked, chipped, or no longer glows\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition attempts\u003c\/li\u003e\n\u003cli\u003eGas valve clicks open but burners never light\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027379962227,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691469171,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_aba0fe5f-97ce-44e0-81c7-c3cbb5975a51.jpg?v=1782894210"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150lrca0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LRCA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM hot surface igniter kit for the ICP\/Tempstar\/Heil RGS150LRCA0AAAA gas furnace includes the igniter (part number 1171306, \"IGNITOR\") and the matching wiring kit (part number 1188370, \"WIRING KIT IGNITER\"). The hot surface igniter is a silicon-based heating element that glows red-hot when energized, lighting the burners at the start of every heat cycle. The included wiring kit provides the correct connector and harness for a clean, code-correct hookup. Igniters are brittle and degrade with thermal cycling — they crack, develop hairline fractures, or simply burn out, which is the single most common reason a furnace ignites no flame and locks out on a failed-ignition fault.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS150LRCA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit replacement for the ICP\/Tempstar\/Heil RGS150LRCA0AAAA and related RGS-series gas furnaces that use this hot surface igniter and connector. Match the igniter mount and harness connector to your unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and unscrew the bracket; handle the old igniter by its ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter (never touch the element), attach the new wiring kit, and seat the connector fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and lights the burners.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks but burners never light\u003c\/li\u003e\n\u003cli\u003eNo glow visible during the ignition sequence\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eRepeated failed-ignition lockouts on the control board\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027381141875,"sku":"1171306","price":51.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691436403,"sku":"1171306-GEN","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_5186ffd1-36bf-4b1d-bb33-7f9aa7c6d43f.jpg?v=1782894207"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150lfca0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LFCA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter kit for the ICP\/Heil\/Tempstar RGS150LFCA0AAAA gas furnace includes the igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On a call for heat, the control board energizes the igniter, which glows white-hot to ignite the burner gas. Hot surface igniters are brittle and degrade with every heating cycle, eventually cracking or losing the ability to reach ignition temperature. The result is no heat, repeated ignition lockouts, or a furnace that cycles on the limit. Including the wiring kit ensures clean, corrosion-free connections so the new igniter receives full voltage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBurner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP, Heil, and Tempstar RGS150LFCA0AAAA and related Comfortmaker\/Day \u0026amp; Night gas furnaces using this hot surface ignition system. Confirm igniter style and connector before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, unfasten the mounting screw, and lift the fragile igniter out by its ceramic base — never touch the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the wiring kit, and reconnect the harness; handle the element only by its base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo heat or repeated ignition lockouts\u003c\/li\u003e\n\u003cli\u003eIgniter fails to glow on a call for heat\u003c\/li\u003e\n\u003cli\u003eVisible cracks or hot spots on the ceramic element\u003c\/li\u003e\n\u003cli\u003eFurnace cycles on the high-limit switch\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027384451443,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691370867,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_8d9d0aff-a998-433d-ab1d-34ff7c754299.jpg?v=1782894202"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150lfab0agaa-includes-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LFAB0AGAA — Includes Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (part 1171306) and matching igniter wiring kit (part 1188370) are the factory ignition components for the ICP \/ Heil \/ Tempstar RGS150LFAB0AGAA gas furnace. The hot surface igniter is a silicon-based element that heats to over 2,000°F when energized by the control board, igniting the gas at the burners on a call for heat. Because the element is brittle and cycles to extreme temperatures every heating call, it is one of the most common no-heat failure points. Including the wiring kit ensures a clean, reliable connection and avoids reusing a heat-fatigued harness.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned as the direct factory replacement for the ICP \/ Heil \/ Tempstar model RGS150LFAB0AGAA. Always handle the igniter only by its ceramic base — skin oils and physical contact with the silicon element will shorten its life.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power to the furnace; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter bracket position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter without bumping the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, holding it by the ceramic base only, and connect the new wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace blower runs but there is no heat\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow on a call for heat\u003c\/li\u003e\n\u003cli\u003eVisible cracks or chips in the silicon element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027386646899,"sku":"1171306","price":49.4,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691305331,"sku":"1171306-GEN","price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_54bdd831-f8d2-4677-b5ae-685e65533650.jpg?v=1782894198"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150lfaa0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LFAA0AAAA - With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter assembly fits the ICP\/Tempstar\/Heil RGS150LFAA0AAAA gas furnace and includes both the igniter element (part number 1171306) and the matching igniter wiring kit (part number 1188370). The hot surface igniter is energized by 120V at the start of each heating cycle, glowing white-hot to light the burners. These ceramic elements are brittle and degrade with every thermal cycle, eventually cracking or losing the ability to reach ignition temperature. When the igniter fails the furnace will not light, producing a no-heat condition that typically locks out after several failed ignition attempts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the factory igniter replacement for ICP model RGS150LFAA0AAAA and equivalent furnaces marketed under the Tempstar, Heil, Comfortmaker, Arcoaire and KeepRite brands. The included wiring kit ensures a clean, correct connection to the furnace control board.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e - Shut off gas and electric power to the furnace, then verify zero voltage at the igniter leads with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e - Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e - Photograph the igniter mounting position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e - Unplug the igniter harness and remove the mounting screw, handling the old element by its bracket only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e - Mount the new igniter without touching the ceramic surface, install the wiring kit, and connect to the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e - Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs but burners never light (no heat).\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow at the start of the heating sequence.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after three failed ignition attempts.\u003c\/li\u003e\n\u003cli\u003eVisible cracks, blistering, or breaks in the ceramic igniter element.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027389399411,"sku":"1171306","price":51.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691239795,"sku":"1171306-GEN","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_8b37fdc5-8829-436c-a9e7-a232eda241ac.jpg?v=1782894193"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150leaa0agaa-silicon-nitride-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LEAA0AGAA — Silicon Nitride with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (part #1171306) is the ignition source for the ICP \/ Tempstar \/ Heil RGS150LEAA0AGAA gas furnace. When the thermostat calls for heat, the control board energizes the igniter; it glows white-hot to ignite the gas at the burners. This listing includes the matching igniter wiring kit (#1188370) so the harness and connector are replaced together. A failed igniter is one of the most common no-heat causes — the element develops hairline cracks or burns out from thermal cycling, breaking the circuit. Operating at line voltage (120V), the element draws current through a thin ceramic\/silicon-nitride body that is fragile to the touch.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP Tempstar Heil RGS150LEAA0AGAA furnace and related RGS150 platform variants. Always confirm against your furnace model and serial label before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power at the furnace switch; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment door\/service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter bracket position and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out — handle only by the ceramic base, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, route and plug in the new wiring kit per your photo, and confirm the element sits in front of the burner port without touching metal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat cycle, and verify the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace blower runs but no heat \/ no ignition\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow during a heat call\u003c\/li\u003e\n\u003cli\u003eVisible cracks, blistering, or white residue on the element\u003c\/li\u003e\n\u003cli\u003eOpen circuit when tested for resistance\/continuity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027396542835,"sku":"1171306","price":41.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691108723,"sku":"1171306-GEN","price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-nitride-1171306_f82797ab-f5c7-4f30-bf5f-c56ce325f371.jpg?v=1782894184"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs150ldcb0aaaa-with-wiring-harness-ships-today","title":"Heil Hot Surface Igniter Kit for RGS150LDCB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (part 1171306) and matching igniter wiring kit (part 1188370) provide reliable ignition for the ICP\/Tempstar\/Heil RGS150LDCB0AAAA gas furnace. On each heat call the furnace control board sends line voltage to the igniter, which glows red-hot to ignite the gas at the burners. Igniters are a wear item — the silicon carbide or silicon nitride element grows brittle with thousands of heating cycles and eventually cracks, leaving the furnace unable to light. The included wiring kit ensures the connector and harness match the furnace control, avoiding the melted or corroded plugs that often accompany an aged igniter.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS150LDCB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the factory replacement igniter assembly for the ICP\/Tempstar\/Heil RGS150LDCB0AAAA and other same-generation Carrier-family gas furnaces using a hot surface ignition system. The bundled wiring kit lets you replace the harness at the same time when the original connector is heat-damaged.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and electrical power, then verify zero voltage with a multimeter before servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and the wiring harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the fragile igniter — never touch the element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter so the element sits in the burner flame path, then connect the new wiring kit to the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light within the normal ignition sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks and the inducer runs but the burners never light\u003c\/li\u003e\n\u003cli\u003eIgniter shows no glow or only a dim, uneven glow\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eControl board locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027398115699,"sku":"1171306","price":51.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209517427,"sku":"1171306-GEN","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_fefbe41e-df04-426e-a44e-56bc48345600.jpg?v=1782877404"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150ldaa0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150LDAA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM hot surface igniter kit for the ICP\/Heil\/Tempstar RGS150LDAA0AAAA gas furnace includes the igniter (PN 1171306) and its matched wiring harness kit (PN 1188370). On a heat call, the control board sends line voltage to the igniter, which glows red-hot to ignite the burner gas. Igniters are brittle silicon-carbide or nitride elements that crack with age, thermal cycling, and contamination from oils — the most common cause of furnace no-heat lockouts. The included wiring harness restores clean, corrosion-free connections so the new igniter receives full voltage for reliable ignition every cycle.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + wiring harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP\/Heil\/Tempstar RGS150LDAA0AAAA and related Heil-family gas furnaces using this hot surface ignition system. Confirm igniter mounting and connector style against your original.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas, disconnect power, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photo the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the connector, unscrew the cracked igniter, and handle the new element by its base only (never touch the ceramic).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, route and plug in the new wiring harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace no-heat \/ ignition lockout\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow on a heat call\u003c\/li\u003e\n\u003cli\u003eVisible cracks or white spots on the element\u003c\/li\u003e\n\u003cli\u003eIntermittent ignition or delayed light-off\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027405029747,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047691010419,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_34960b09-8aaa-4747-941f-4501e8d502d1.jpg?v=1782894178"},{"product_id":"icp-hot-surface-igniter-kit-with-wiring-harness-for-rgs150hscb0aaaa-oem-ships-today","title":"ICP Hot Surface Igniter Kit with Wiring Harness for RGS150HSCB0AAAA — OEM | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eGenuine OEM hot surface igniter (part 1171306) plus the matching igniter wiring kit (part 1188370) for the ICP \/ Tempstar \/ Heil RGS150HSCB0AAAA packaged gas\/electric unit. The hot surface igniter receives line voltage on a call for heat, glows red-hot, and ignites the gas at the burners. It is the single most common no-heat failure point in modern gas equipment — the brittle silicon-carbide or nitride element cracks from thermal cycling, oil contamination from bare-hand contact, or simple age. The included wiring kit ensures a clean, factory-correct electrical connection so you're not splicing onto a degraded harness.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP RGS150HSCB0AAAA and related RGS-series packaged units using the same hot surface ignition system. Verify against your model's burner\/ignition assembly before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photo the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw; handle the old igniter by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then connect the new wiring kit per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo heat with the inducer running but no ignition\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weak\/uneven\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027408077171,"sku":"1171306","price":49.4,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047694811507,"sku":"1171306-GEN","price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_8512e640-12e7-48ac-831c-b54fd7827321.jpg?v=1782894423"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs150hfcb0aaaa-with-wiring-harness-ships-today","title":"Heil Hot Surface Igniter Kit for RGS150HFCB0AAAA — with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (HSI) is what lights the burners on your ICP \/ Tempstar \/ Heil RGS150HFCB0AAAA gas furnace. On a call for heat, the control board sends 120V to the igniter, which glows white-hot and ignites the gas as the valve opens. We bundle the igniter (OEM 1171306) with the matching igniter wiring kit (OEM 1188370) so you replace the brittle, heat-stressed element and its connector together — the most reliable repair. Hot surface igniters are fragile and degrade with every heating cycle. Common failure symptoms include no ignition and the furnace locking out, a cracked or visibly broken element, the igniter glowing but the burners never lighting, or repeated short-cycling on ignition failure.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter) + 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirectly fits the ICP\/Tempstar\/Heil RGS150HFCB0AAAA gas furnace and other models sharing the same igniter assembly. The included wiring kit ensures a clean connection to the furnace control board.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw; handle the old element by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element surface, then connect the new wiring kit to the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace locks out with no ignition\u003c\/li\u003e\n\u003cli\u003eCracked, chipped, or visibly broken igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter glows but burners never light\u003c\/li\u003e\n\u003cli\u003eRepeated short-cycling on ignition failure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027415613811,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209484659,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_c093e2ff-e37e-488c-9238-277f8fe82083.jpg?v=1782877402"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150hfaa0akaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150HFAA0AKAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter kit for the ICP\/Heil\/Tempstar RGS150HFAA0AKAA includes the igniter element (P\/N 1171306) and the matching igniter wiring kit (P\/N 1188370). On a call for heat, the control board energizes the igniter, which glows red-hot to ignite the gas at the burners. Hot surface igniters are brittle and degrade with every heat cycle, eventually cracking or losing the ability to reach ignition temperature. The included wiring kit ensures a clean, correct electrical connection and replaces brittle or heat-damaged leads. A failed igniter is one of the most common no-heat causes — installing the OEM igniter with fresh wiring restores fast, dependable ignition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP\/Heil\/Tempstar RGS150HFAA0AKAA and related gas furnaces using a hot surface ignition system. Confirm your igniter mounting style before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and unscrew the old igniter; handle the new element by its base only — never touch the silicon carbide tip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, connect the new wiring kit, and route leads clear of hot surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then run a heat cycle and confirm the igniter glows and burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo heat — igniter fails to glow on a call for heat\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after failed ignition attempts\u003c\/li\u003e\n\u003cli\u003eBrittle, frayed, or heat-damaged igniter wiring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027421053299,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690846579,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_cf6a04be-eb38-4a10-aab5-d6cabad44eb3.jpg?v=1782894169"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150hecb0aaaa-gas-furnace-includes-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150HECB0AAAA Gas Furnace — Includes Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter assembly is the ignition source for the ICP Tempstar Heil RGS150HECB0AAAA 150,000 BTU gas furnace. When the thermostat calls for heat, the control board energizes this igniter; its silicon-carbide element glows red-hot and lights the burners. Over time the brittle element develops hairline cracks or carbon buildup that prevent it from reaching ignition temperature, producing no-heat calls, repeated lockouts, or a furnace that clicks but never lights. This listing covers OEM igniter part \u003cstrong\u003e1171306\u003c\/strong\u003e together with igniter wiring kit \u003cstrong\u003e1188370\u003c\/strong\u003e, so you replace the element and its harness in one job.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the ICP \/ Tempstar \/ Heil RGS150HECB0AAAA furnace and shared-platform RGS-series models that call out igniter 1171306. Because ICP, Tempstar, Heil, and Comfortmaker furnaces are built on common chassis, this igniter fits many sister units — always confirm against your unit's parts list before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off the gas at the valve and disconnect electrical power. Verify zero voltage at the control board with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter bracket position and the harness routing before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, back out the mounting screw, and withdraw the old igniter carefully. Never touch the new element with bare fingers — skin oils cause hot spots and early failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1171306 igniter in the same orientation, route and plug in the 1188370 wiring kit per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat cycle, and confirm the igniter glows, burners light cleanly, and there are no lockouts.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks and tries to start but the burners never light.\u003c\/li\u003e\n\u003cli\u003eVisible cracks, white discoloration, or carbon on the igniter element.\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts requiring a power-cycle to reset.\u003c\/li\u003e\n\u003cli\u003eNo glow visible through the sight port during a heat call.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027423805811,"sku":"1171306","price":54.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690813811,"sku":"1171306-GEN","price":42.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_f9b08469-7866-41e5-b9cd-102758744d7a.jpg?v=1782894167"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150hdba0agaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150HDBA0AGAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (HSI) is the ignition source for your ICP Tempstar Heil RGS150HDBA0AGAA gas furnace. On a call for heat the control board sends line voltage to the igniter (OEM 1171306), which glows red-hot to light the burners. This listing pairs the igniter with the matching igniter wiring kit (OEM 1188370) so you replace both the element and the harness\/connector that commonly degrades from repeated heat cycling. A cracked or worn igniter is the leading cause of furnace no-heat calls — it is brittle silicon carbide or nitride and fails from thermal stress and oil contamination from bare-hand contact.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + igniter wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP Tempstar Heil RGS150HDBA0AGAA and related RGS150 series gas furnaces. The included wiring kit ensures a clean electrical connection between the igniter and the furnace control board.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment door to reach the igniter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the new element with bare hands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter at the correct depth, install the new wiring kit, and reconnect to the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then confirm a clean glow-and-light sequence on a call for heat.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blows cold air or short-cycles on ignition lockout\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow on a call for heat\u003c\/li\u003e\n\u003cli\u003eVisible cracks, blisters, or white-spotting on the element\u003c\/li\u003e\n\u003cli\u003eBurners fail to light despite gas and spark sequence\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027434062195,"sku":"1171306","price":48.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690682739,"sku":"1171306-GEN","price":36.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_f3ab129b-9924-42e5-b37d-7e7c34c78d0d.jpg?v=1782894158"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs150hdaa0aaaa-igniter-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS150HDAA0AAAA — Igniter + Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eGenuine OEM hot surface igniter (part 1171306) bundled with its matching igniter wiring kit (part 1188370) for the ICP \/ Tempstar \/ Heil RGS150HDAA0AAAA gas furnace. The hot surface igniter glows to ignite the gas at the burners on each heat call. Igniters are brittle and degrade over thousands of cycles; a cracked or weak igniter is the most common cause of no-heat calls and intermittent ignition lockouts. The included wiring kit replaces the brittle, heat-aged igniter leads and connector so the new igniter gets a clean, reliable connection.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eGenuine OEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP \/ Tempstar \/ Heil RGS150HDAA0AAAA and related RGS-series gas furnaces. Verify the igniter mounting and connector against your existing part before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and shut off the gas supply; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/control access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting position and wiring routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter (handle by the ceramic base only).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the wiring kit, and connect the harness — never touch the igniter element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo heat or repeated ignition lockout codes\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all\u003c\/li\u003e\n\u003cli\u003eDelayed ignition or burner rollout on startup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027438813555,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690617203,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_889f46e0-696e-48d2-adfc-e7abf3951e41.jpg?v=1782894154"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121stca0aaa-includes-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121STCA0AAA — Includes Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM hot surface igniter kit for the ICP\/Tempstar\/Heil RGS121STCA0AAA furnace includes the igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On a call for heat, the control board energizes the igniter, which glows red-hot to ignite the gas at the burners. Hot surface igniters are fragile and degrade with every heating cycle — they crack, develop hairline fractures, or burn out entirely. A failed igniter is one of the most common causes of no-heat calls in modern gas furnaces.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP RGS121STCA0AAA and related Tempstar, Heil, and Comfortmaker gas furnaces using this hot surface ignition system. The included wiring kit ensures a clean, correct connection to the furnace harness.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and carefully unscrew the old igniter without touching the element with bare hands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, handling it only by the ceramic base, and connect the new wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat cycle, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blows cold air or fails to ignite on a heat call\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows during the ignition sequence\u003c\/li\u003e\n\u003cli\u003eRepeated lockouts after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027441664371,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690551667,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_2bf2a176-96f8-4da2-963a-738f108a7332.jpg?v=1782894148"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121stbb0aaaa-oem-igniter-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121STBB0AAAA — OEM Igniter with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM kit pairs the hot surface igniter, ICP part number 1171306, with its matching wiring harness kit, part number 1188370. The hot surface igniter is the component that glows red-hot at the start of each heating cycle to ignite the gas at the burners. The included wiring kit provides the correct connector and leads for a clean, reliable connection to the furnace control board. Hot surface igniters are fragile and degrade with every cycle — the silicon-carbide or silicon-nitride element becomes brittle and eventually cracks or fails to reach ignition temperature. When that happens, the furnace runs its sequence but never lights, often locking out after several failed attempts. Replacing the igniter and its harness together restores dependable ignition and avoids intermittent connector faults.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit OEM replacement for the ICP \/ Tempstar \/ Heil model RGS121STBB0AAAA and shared-platform gas furnaces using this hot surface igniter. Confirm the igniter mounting and connector match your existing part before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas, disconnect power, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the brittle igniter without touching the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter handling it only by the ceramic base, then connect the new wiring harness to the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the normal sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace runs its cycle but the burners never ignite\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weakly\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027443040627,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690518899,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_3927c8e1-ad86-405f-b800-bdf7ba14a1f8.jpg?v=1782894146"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121stab0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121STAB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit pairs the igniter element (part 1171306) with its matching igniter wiring harness\/kit (part 1188370) for ICP Tempstar\/Heil gas furnaces. On each call for heat, the furnace control sends voltage to the igniter, which glows white-hot and lights the gas at the burners. The igniter is one of the most failure-prone components in a furnace because the brittle element is heat-cycled hundreds of times per season and is easily cracked by handling or contamination. Including the wiring harness ensures a clean, corrosion-free connection from the control board to the igniter — a frequent secondary failure point. Replacing both together restores reliable, fast ignition and eliminates the no-heat, repeated-retry, and lockout symptoms caused by a cracked element or a chafed, melted harness.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + wiring harness\/connector kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFits ICP, Tempstar, Heil, and Comfortmaker gas furnaces including model RGS121STAB0AAAA. Confirm the igniter mounting tab and connector style against your existing part before installing. Handle the new element by the ceramic base only — never touch the silicon-carbide tip.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position, mounting tab, and harness routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harness, remove the igniter mounting screw, and carefully withdraw the cracked element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter (handling by the base only), route and connect the new wiring harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the igniter glows and lights the burners promptly on a heat call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat — burners never ignite on a call\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow, or glows weakly\u003c\/li\u003e\n\u003cli\u003eRepeated ignition retries followed by lockout\u003c\/li\u003e\n\u003cli\u003eVisible crack in the element or melted\/chafed harness\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day for orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027445530995,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690486131,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_6e8e7270-7aec-432d-8c7f-f0d823703481.jpg?v=1782894143"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121staa0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121STAA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM igniter service kit includes the ICP hot surface igniter, part number 1171306, and the matching igniter wiring kit, part number 1188370, for the RGS121STAA0AAAA gas furnace. The hot surface igniter (HSI) glows red-hot when energized to ignite the gas at the burners on each heat call, and the included wiring harness ensures a clean, correct electrical connection back to the control board. HSIs are fragile and degrade with every heating cycle — they crack from thermal stress, vibration, or even an oily fingerprint. When the igniter fails, the furnace will go through its inducer and prepurge sequence but never light, often locking out after several failed attempts and leaving the home without heat.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Model\u003c\/td\u003e\n\u003ctd\u003eRGS121STAA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP\/Tempstar\/Heil RGS121STAA0AAAA furnace and other ICP-family furnaces using this hot surface igniter and harness. Confirm the igniter element shape and connector against your original before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker; verify zero voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the old igniter at the connector and remove its mounting screw(s). Handle the new igniter by the ceramic base only — never touch the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1171306 igniter, connect the 1188370 wiring kit, and route the harness clear of hot or moving parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and run a heat cycle to confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs the inducer but burners never ignite.\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow, or glows weakly.\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the igniter element.\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts after several attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027446153587,"sku":"1171306","price":46.8,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690453363,"sku":"1171306-GEN","price":36.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_838b515a-f619-4bff-8740-841f497b2b8e.jpg?v=1782894141"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121srcb0aaa-igniter-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SRCB0AAA — Igniter + Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM hot surface ignition kit for the ICP \/ Tempstar \/ Heil RGS121SRCB0AAA gas furnace, including the hot surface igniter (part number 1171306) and the matching igniter wiring kit\/harness (part number 1188370). The hot surface igniter glows red-hot on a call for heat to ignite the burner gas; it is one of the most common furnace failure points because the element is brittle and degrades with every heating cycle. The included wiring kit ensures a clean, correct electrical connection and replaces brittle or heat-damaged leads. When the igniter cracks or the element opens, the furnace will not light — you may hear the gas valve and inducer cycle with no ignition, or see a lockout fault. This complete kit restores reliable ignition with the exact OEM components.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (Igniter)\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (Wiring Kit)\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS121SRCB0AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP-family RGS121SRCB0AAA and shared across many Tempstar, Heil, Comfortmaker, and ICP gas furnaces using this hot surface igniter platform. Confirm the igniter and harness part numbers against your existing parts before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner\/service panel to reach the igniter at the burner assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and carefully unscrew the brittle old igniter — handle by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then connect the new wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat call, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace will not light — no glow at the igniter\u003c\/li\u003e\n\u003cli\u003eInducer and gas valve cycle with no ignition\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027447038323,"sku":"1171306","price":46.8,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690420595,"sku":"1171306-GEN","price":36.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_7f1aa4e8-16ac-4690-8d46-a93149bd580c.jpg?v=1782894139"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121srca0aaa-120v-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SRCA0AAA — 120V with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit is the direct-fire ignition source for the ICP \/ Tempstar \/ Heil RGS121SRCA0AAA gas furnace. The kit includes igniter part number 1171306 and the matching wiring kit 1188370, so you get both the silicon-nitride\/carbide element and the harness needed to land it cleanly on the furnace control board. When the thermostat calls for heat, the control board energizes the igniter; it glows white-hot and lights the gas at the burner. A cracked, eroded, or carbon-fouled igniter is the single most common cause of furnace no-heat lockouts. Replacing it with the correct OEM part restores reliable, fast ignition and avoids the repeated short-cycling that wears out the gas valve and pressure switch.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eRGS121SRCA0AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the ICP \/ Tempstar \/ Heil RGS121SRCA0AAA gas furnace and the closely related RGS121 series sharing the same ignition assembly. Always confirm the OEM number stamped on your existing igniter and harness before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off the gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and the wiring harness routing before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness from the control board, remove the igniter mounting screw, and lift out the old igniter. Handle only by the ceramic base — never touch the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new igniter so the element sits in the burner flame path, secure the screw, and route the new wiring kit back to the board per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners within the normal ignition window.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs but no flame — repeated no-heat lockouts.\u003c\/li\u003e\n\u003cli\u003eIgniter shows visible cracks, hot spots, or white powdery erosion.\u003c\/li\u003e\n\u003cli\u003eNo glow at the igniter during a heat call.\u003c\/li\u003e\n\u003cli\u003eFurnace short-cycles or trips after several failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027448250739,"sku":"1171306","price":48.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690387827,"sku":"1171306-GEN","price":36.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_85bddbed-7ba8-489c-a2ef-3be4a68f9d55.jpg?v=1782894137"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121srbb0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SRBB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit fits the ICP \/ Heil \/ Tempstar RGS121SRBB0AAAA gas furnace and includes the igniter (part number 1171306) plus the matching igniter wiring kit (part number 1188370). The hot surface igniter is a silicon-nitride\/carbide element that glows red-hot when energized to light the burners at the start of each heating cycle. Because the element is brittle and degrades with every ignition, it is one of the most frequently replaced furnace parts. The included wiring kit ensures a clean, correct connection to the control board so you replace the harness and igniter together.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFactory replacement for the ICP\/Heil\/Tempstar RGS121SRBB0AAAA and related RGS-series gas furnaces. The igniter and wiring kit are sold here as the matched OEM service set. Confirm your furnace's igniter part number and mounting style before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power at the breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, route and connect the new wiring kit, handling the element only by its ceramic base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat — burners never light despite the inducer and gas valve operating.\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the igniter element.\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027449692531,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690355059,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_d6e9e0cb-09e0-48e2-8c47-a7dd3878c93e.jpg?v=1782894135"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121srab0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SRAB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit for the ICP \/ Tempstar \/ Heil RGS121SRAB0AAAA gas furnace includes the igniter (part 1171306) and the matched igniter wiring kit (part 1188370). The hot surface igniter glows when 120V is applied at the start of each heat cycle, igniting the burners as the gas valve opens. Because the element is brittle silicon carbide or nitride, it is the single most common cause of intermittent no-heat calls — it cracks from thermal cycling, contamination from oily fingerprints, or simple age. The included wiring kit ensures clean, factory-correct connections so the new igniter receives full voltage. Replacing both together restores reliable ignition and eliminates the repeated lockouts that come from a weak or cracked element.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect factory replacement for the ICP RGS121SRAB0AAAA and compatible Tempstar, Heil, and Comfortmaker gas furnaces that use this hot surface igniter and harness. Verify your furnace model and existing igniter style before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect furnace power, then verify zero voltage at the igniter leads with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the new element with bare hands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, route and connect the included wiring kit, and confirm the element sits correctly over the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and verify the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs but the burners never ignite (no heat).\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the igniter element.\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all on a call for heat.\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or short-cycling on heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027451462003,"sku":"1171306","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690322291,"sku":"1171306-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_9f7dc996-0fcf-418d-9e0d-3ae7dddcfc62.jpg?v=1782894132"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121sfbb0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SFBB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM hot surface igniter kit for the ICP \/ Heil \/ Tempstar RGS121SFBB0AAAA gas furnace, including the igniter (OEM 1171306) and its dedicated wiring kit (OEM 1188370). On each heat call the control board sends voltage to the igniter, which glows red-hot to ignite the gas at the burners. The element is brittle and degrades with every cycle — a cracked or oxidized igniter is the single most common cause of no-heat furnace failures. The included wiring harness ensures a clean, correct electrical connection so the new igniter receives full voltage.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + wiring harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFurnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP RGS121SFBB0AAAA and related RGS-series Heil, Tempstar, and Comfortmaker gas furnaces using a hot surface ignition system. Match the igniter mount and connector to your original before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect electrical power and verify zero voltage with a multimeter; shut off the gas if servicing burners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harness and unscrew the cracked igniter — handle only by the ceramic base, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then connect the new wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and gas, start a heat cycle, and confirm the igniter glows and burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blows cold air with no ignition\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows on a heat call\u003c\/li\u003e\n\u003cli\u003eRepeated lockouts after several ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027455852915,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690256755,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_21907f8d-1fed-4ecc-baa3-aa633428e03a.jpg?v=1782894128"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121sfba0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SFBA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit for the ICP RGS121SFBA0AAAA gas furnace includes the ignitor (part 1171306) and the matching igniter wiring kit (part 1188370). On each heat call the control board energizes the igniter, which glows red-hot to light the burners. Hot surface igniters are brittle and degrade with every cycle — a hairline crack or carbon buildup causes weak ignition, delayed light-off, or a complete no-heat condition. Including the wiring kit ensures a clean, properly terminated connection and avoids reusing brittle, heat-aged leads. Genuine parts restore fast, reliable ignition and consistent furnace operation.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Ignitor), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBurner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP\/Tempstar\/Heil RGS121SFBA0AAAA gas furnace and related models using this hot surface igniter and connector. Verify the igniter mounting and connector match your existing part before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and unscrew the bracket; handle the element by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the silicon-carbide element, then connect the new wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blower runs but burners never light\u003c\/li\u003e\n\u003cli\u003eVisible crack or chip in the igniter element\u003c\/li\u003e\n\u003cli\u003eDelayed ignition or a small \"poof\" at light-off\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027456737651,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690223987,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_73099871-97b2-4e08-a904-e6c300e205a8.jpg?v=1782894126"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121sfab0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SFAB0AAAA — with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM hot surface igniter kit for the ICP \/ Tempstar \/ Heil RGS121SFAB0AAAA gas furnace, including the igniter (part 1171306) and its matched wiring kit (part 1188370). On a call for heat, the control board sends line voltage to the igniter, which glows white-hot and lights the burners as gas is introduced. Hot surface igniters are a high-wear consumable: the element is brittle and slowly erodes with every heating cycle until it cracks and can no longer reach ignition temperature. The included wiring kit ensures a clean, correctly terminated connection — important because a corroded or loose igniter plug is a common cause of intermittent no-heat calls. Replacing both together restores reliable first-try ignition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide \/ silicon nitride style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + matched wiring harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP-family RGS121SFAB0AAAA and related Tempstar, Heil, and Comfortmaker gas furnaces using this hot surface ignition system. Confirm the mounting tab and connector match your existing igniter before installing — and never touch the element with bare fingers, as skin oils shorten its life.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect electrical power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photo the igniter's position, bracket, and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the brittle igniter without bumping it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new igniter in the same position (handling only the ceramic base), secure the screw, and connect the new wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and burners light cleanly within the normal ignition sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace clicks and calls for heat but burners never light\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows or glows weakly\/unevenly\u003c\/li\u003e\n\u003cli\u003eVisible cracks, blistering, or hot spots on the element\u003c\/li\u003e\n\u003cli\u003eIntermittent no-heat lockouts that clear on reset\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027457884531,"sku":"1171306","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690191219,"sku":"1171306-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_4ce8dd1b-65f4-4185-b5e9-9edf2b437f0c.jpg?v=1782894123"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121sfaa0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SFAA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM hot surface igniter kit for the ICP \/ Tempstar \/ Heil RGS121SFAA0AAAA includes the igniter element (part 1171306) and the matching igniter wiring kit (part 1188370). On a call for heat, the control board sends line voltage to the igniter, which glows white-hot to light the gas at the burners. Hot surface igniters are fragile and degrade over thousands of heating cycles — the element develops hairline cracks or simply ages until it no longer reaches ignition temperature, leaving you with a furnace that clicks but never fires. Bundling the wiring kit ensures the brittle, heat-aged leads and connector are replaced at the same time, eliminating a common hidden cause of intermittent no-heat faults.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness\/connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit replacement for the ICP RGS121SFAA0AAAA gas furnace and other ICP-family models (Tempstar, Heil, Comfortmaker) using this hot surface igniter and connector. Match the igniter mounting tab and connector style to your existing part before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and the wiring connector routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the new element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the new wiring kit\/connector, and route leads clear of hot surfaces exactly as photographed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat cycle, and confirm the igniter glows and the burners light within the normal sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks and the inducer runs but burners never light\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or white blistering on the igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all on a heat call\u003c\/li\u003e\n\u003cli\u003eIntermittent no-heat that worsens with melted or brittle igniter wiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027458670963,"sku":"1171306","price":51.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690158451,"sku":"1171306-GEN","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_2fb18dcb-2d77-4d8d-80f7-78a9f5de314e.jpg?v=1782894121"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121sebb0aaaa-includes-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SEBB0AAAA — Includes Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (part 1171306) is the ignition source for your ICP\/Heil\/Tempstar RGS121SEBB0AAAA gas furnace. When the thermostat calls for heat, the control board sends voltage to the igniter, which glows red-hot to ignite the gas at the burners. This kit also includes the matching igniter wiring kit (part 1188370) so you replace the harness and connector at the same time, eliminating a common second point of failure. A cracked or worn igniter is one of the most frequent causes of no-heat calls.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS121SEBB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as a direct OEM fit for the ICP\/Heil\/Tempstar RGS121SEBB0AAAA furnace and closely related models in the RGS121 series. Always confirm your model and serial before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and shut off gas, verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter wiring and routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw; lift out the old igniter, handling the ceramic carefully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter and connect the new wiring kit, keeping the element clear of the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat cycle, and confirm the igniter glows and burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace blows cold air or fails to ignite on a heat call\u003c\/li\u003e\n\u003cli\u003eVisible cracks or hot spots on the ceramic element\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows or glows weakly\u003c\/li\u003e\n\u003cli\u003eRepeated lockouts after several ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027462144371,"sku":"1171306","price":49.4,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690092915,"sku":"1171306-GEN","price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_7e1251fb-d95b-469f-a456-70586c450349.jpg?v=1782894117"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121seab0aaaa-oem-1171306-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121SEAB0AAAA — OEM 1171306 with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter assembly (part 1171306) with matching igniter wiring kit (part 1188370) is the exact ignition component for the ICP \/ Tempstar \/ Heil RGS121SEAB0AAAA gas furnace. The hot surface igniter (HSI) glows red-hot when the control board calls for heat, lighting the gas at the burners. It is one of the most common no-heat failure points in a furnace because the silicon-carbide or silicon-nitride element is brittle and degrades with every ignition cycle. Typical failure symptoms include the furnace blower running without heat, repeated ignition lockouts, a cracked or visibly damaged igniter element, or a unit that clicks but never lights.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP-family RGS121SEAB0AAAA furnace and other Tempstar, Heil, Comfortmaker, and Day \u0026amp; Night models that call out igniter 1171306. Always confirm against your unit's parts list before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the lower service panel to expose the burner assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting bracket and the wiring connector before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out without touching the element with bare hands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1171306 igniter, route and connect the 1188370 wiring kit, and seat the bracket so the element sits in the burner flame path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then call for heat and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace blower runs but never produces heat\u003c\/li\u003e\n\u003cli\u003eVisible crack, blister, or break in the igniter element\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockout after 3 failed tries\u003c\/li\u003e\n\u003cli\u003eNo glow at the igniter during a heat call\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027464110451,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047690060147,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_8f95fd04-6f1d-41cf-bdd6-20c7e5bf88ae.jpg?v=1782894115"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121ltaa0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121LTAA0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter kit for the ICP \/ Heil \/ Tempstar RGS121LTAA0AAAA gas furnace includes the igniter (part number 1171306) and the matching igniter wiring kit (part number 1188370). The hot surface igniter is the heart of furnace ignition: on a call for heat, the control board sends voltage to the igniter, its element glows red-hot, and that surface lights the gas at the burners. Igniters are brittle and consumable — repeated heat cycling, hairline cracks, contamination, or simple age cause them to fail. The included wiring kit ensures a clean, correct connection and replaces brittle or heat-damaged igniter leads at the same time.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS121LTAA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eBuilt for the ICP RGS121LTAA0AAAA and used across many ICP-family RGS-series furnaces sold as Heil, Tempstar, Comfortmaker, and Arcoaire. Confirm the igniter and wiring kit part numbers against your furnace before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Turn off gas and electrical power to the furnace. Verify zero voltage with a multimeter before proceeding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter — handle only by the ceramic base, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter so the element sits in the burner flame path without touching metal, then connect the new wiring kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly and evenly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace clicks but burners never light (no glow)\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or short-cycling on a heat call\u003c\/li\u003e\n\u003cli\u003eBrittle, frayed, or heat-damaged igniter wiring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027471778163,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047689994611,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_92d7eceb-c6fd-4690-a8b4-3eed43037696.jpg?v=1782894110"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121lscb0aaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121LSCB0AAA — with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit (igniter #1171306 with wiring kit #1188370) lights the main burners on your ICP RGS121LSCB0AAA gas furnace. On a call for heat, the control board sends line voltage to the igniter, which glows to roughly 2,000°F and ignites gas at the burner. Hot surface igniters are a wear item — the silicon carbide or nitride element grows brittle with every heat cycle and eventually cracks, leaving you with no flame and no heat. The included wiring kit ensures a clean, terminated connection to the furnace harness so you're not splicing brittle factory leads. Because a hairline crack is often invisible, an igniter that ohms out of spec or fails to glow should be replaced as a complete assembly.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the factory igniter assembly for the ICP RGS121LSCB0AAA gas furnace and shared across compatible ICP-family Tempstar, Heil, and Comfortmaker models. Verify your furnace uses a 120V hot surface igniter (not a spark or intermittent pilot system) before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power, verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter bracket position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and unscrew the old igniter — handle only by the ceramic base, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, terminate the included wiring kit, and reconnect per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full heat cycle to confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat — burners never ignite\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow on a heat call\u003c\/li\u003e\n\u003cli\u003eVisible cracks or a broken element\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027472367987,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047689961843,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_f36aef9a-7eb1-4be0-9be8-461fab529ba0.jpg?v=1782894108"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121lsbb0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121LSBB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM hot surface igniter (part number 1171306) with its matching wiring kit (part number 1188370) is the ignition component for the ICP RGS121LSBB0AAAA gas furnace. When the furnace calls for heat, the control board sends voltage to the igniter, which glows white-hot to light the burners. Hot surface igniters are brittle and degrade over time — thermal cycling eventually cracks the silicon carbide or nitride element, leaving a furnace that clicks, draws, but never lights. Because the igniter is the single most common no-heat failure point, replacing it with the correct OEM element and harness is the fastest way to restore reliable ignition. The included wiring kit ensures a clean, factory-correct connection and eliminates brittle, heat-damaged leads.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (Igniter)\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (Wiring Kit)\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBurner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS121LSBB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the factory replacement for the ICP RGS121LSBB0AAAA and the Tempstar, Heil, and Comfortmaker furnaces that share this igniter and harness assembly. Handle the element only by its ceramic base — skin oils and rough handling shorten igniter life.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and remove the mounting screw; lift out the cracked igniter without touching the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, route and connect the new wiring kit per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks and the inducer runs but burners never light\u003c\/li\u003e\n\u003cli\u003eIgniter shows visible cracks or no longer glows\u003c\/li\u003e\n\u003cli\u003eIntermittent no-heat, especially on cold mornings\u003c\/li\u003e\n\u003cli\u003eControl board locks out after repeated failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027474202995,"sku":"1171306","price":48.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047689929075,"sku":"1171306-GEN","price":36.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_b0550f6c-47df-4ae5-b0a2-fdbc69aa5b83.jpg?v=1782894106"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121lrbb0aaaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121LRBB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM hot surface igniter (part number 1171306), paired with its matching igniter wiring kit (part number 1188370), is the ignition source for the ICP Tempstar\/Heil RGS121LRBB0AAAA gas furnace. On a heat call the control board sends voltage to the igniter, which glows red-hot to ignite the burner gas. Hot surface igniters are brittle and have a finite service life — they crack, develop hairline fractures, or simply burn out from repeated cycling. When the igniter fails, the furnace will not light: you'll hear the inducer and gas valve cycle but get no flame, often ending in a lockout. The included wiring kit ensures a clean, corrosion-free connection to the harness.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS121LRBB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP\/Tempstar\/Heil RGS121LRBB0AAAA gas furnace and RGS121 series units using this hot surface igniter platform. Confirm your model and igniter style on the rating plate before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas, disconnect power, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position, bracket, and harness routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and unscrew the old igniter — handle only by the ceramic base, never the fragile element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the wiring kit, and connect the harness without touching the hot surface element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat call, and confirm the igniter glows and lights the burners.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace cycles but the burners never light\u003c\/li\u003e\n\u003cli\u003eIgniter shows visible cracks or no glow on a heat call\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or flashing fault codes\u003c\/li\u003e\n\u003cli\u003eFrayed or corroded igniter wiring connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027480756595,"sku":"1171306","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047689830771,"sku":"1171306-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_927b40d8-6c72-47b9-bc1f-7fa9bf30ee58.jpg?v=1782894099"},{"product_id":"icp-hot-surface-igniter-kit-for-rgs121lfca0aaa-with-wiring-harness-ships-today","title":"ICP Hot Surface Igniter Kit for RGS121LFCA0AAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit for the ICP Tempstar Heil RGS121LFCA0AAA gas furnace includes the igniter (part 1171306) and the matching igniter wiring kit (part 1188370). On every heat call, the control board energizes the igniter, which glows red-hot to ignite the main burners; the wiring kit provides the correct connector and lead to tie the igniter into the harness. Hot surface igniters are a brittle, high-wear part that degrades with each thermal cycle and eventually cracks or fails to reach ignition temperature — the most common cause of a furnace that blows cold air or locks out. This kit restores reliable ignition with the proper igniter and pre-terminated wiring.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Exact Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFurnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt for the ICP Tempstar Heil RGS121LFCA0AAA gas furnace and related RGS-series furnaces using a hot surface igniter. Handle the igniter only by its ceramic base — skin oils and finger contact shorten its life.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photo the igniter position, bracket, and wiring routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter lead, remove the mounting screw, and carefully withdraw the fragile old igniter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter by its ceramic base, connect the new wiring kit, and route the lead away from heat per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat cycle, and confirm the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace blows cold air or fails to light the burners\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow during the ignition sequence\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or white-spotting on the igniter element\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or short cycling on a heat call\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027485933939,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047689765235,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_91c56d9e-7e39-4a79-a3bb-a0f5dc1d2fdb.jpg?v=1782894095"}],"url":"https:\/\/nationalhvacparts.com\/collections\/wiring-harnesses.oembed?page=12","provider":"National HVAC Parts","version":"1.0","type":"link"}