{"title":"Heil Parts","description":"\u003cp\u003eOEM Heil HVAC parts — same factory as Tempstar, ICP, and Comfortmaker. Every Heil part is interchangeable across the entire ICP family.\u003c\/p\u003e","products":[{"product_id":"heil-hot-surface-igniter-for-wpg4244040lka1-oem-ignitor-control-ships-today","title":"Heil Hot Surface Igniter for WPG4244040LKA1 — OEM Ignitor \u0026 Control | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM hot surface igniter assembly for the ICP\/Tempstar\/Heil model WPG4244040LKA1, covering both the ignitor element (Part No. 1177663) and its igniter control board (Part No. 1186861). On a call for heat, the control board sequences the ignition: it powers the hot surface igniter, which glows to roughly 2,000°F to light the burners, then confirms flame before allowing the gas valve to stay open. A failed igniter is the leading cause of no-heat furnace calls. Typical symptoms include a furnace that clicks and runs the inducer but never ignites, an igniter that no longer glows, visible cracks in the silicon-carbide or silicon-nitride element, or a unit that locks out after several failed ignition attempts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1177663 (Ignitor), 1186861 (Igniter Control Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the OEM replacement for ICP\/Tempstar\/Heil model WPG4244040LKA1. These ignition components are shared across many gas furnaces and gas package units in the same brand family. Confirm your existing part numbers before ordering, and handle the igniter element only by its ceramic base.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/blower access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and all wire connections before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and unscrew the element from the burner assembly; never touch the glow element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter in the same orientation, reconnect the harness and control board leads per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then verify a full ignition sequence with a clean glow, burner light-off, and steady flame.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIgniter no longer glows on a call for heat\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition attempts\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eInducer and gas valve cycle but burners never light\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021520126323,"sku":"1186861","price":55.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209288051,"sku":"1186861-GEN","price":42.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1186861.jpg?v=1782877391"},{"product_id":"heil-x-13-blower-motor-for-wpg4244040lka1-1-2-hp-ecm-ships-today","title":"Heil X-13 Blower Motor for WPG4244040LKA1 — 1\/2 HP ECM | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM 1\/2 HP X-13 blower motor (Part No. 1186862) for the ICP\/Tempstar\/Heil model WPG4244040LKA1. The X-13 is a constant-torque ECM (electronically commutated motor) that drives the indoor blower wheel, moving conditioned air through the supply ductwork during heating, cooling, and fan-only operation. Compared to a standard PSC motor, the X-13 delivers higher efficiency, soft starts, and programmed airflow tied to multiple tap settings. Symptoms of a failing motor include no airflow from the registers, a blower that won't start or only hums, intermittent operation, overheating and thermal cutout, or noisy\/grinding bearings. Because the indoor blower is essential to both heating and cooling, a dead X-13 takes the entire system offline.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1186862\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eX-13 Constant-Torque ECM Blower Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndoor Furnace \/ Air Handler Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the OEM replacement for ICP\/Tempstar\/Heil model WPG4244040LKA1. This 1\/2 HP X-13 motor is used across many furnaces and air handlers in the same brand family that specify a constant-torque ECM blower. Verify the part number, horsepower, and tap configuration against your existing motor before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower compartment access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the motor harness, tap connections, and blower wheel position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the motor leads and control plug, loosen the wheel set screw, and slide the blower assembly out to free the old motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Transfer the blower wheel, mount the new X-13 motor, set the wheel position, and reconnect the harness and taps per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify smooth start-up, correct airflow on each speed tap, and quiet operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo airflow from supply registers on heat, cool, or fan\u003c\/li\u003e\n\u003cli\u003eBlower hums but won't spin, or starts intermittently\u003c\/li\u003e\n\u003cli\u003eMotor overheats and trips its thermal protector\u003c\/li\u003e\n\u003cli\u003eGrinding, rattling, or worn-bearing noise from the blower\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021520159091,"sku":"1186862","price":577.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047210402163,"sku":"1186862-GEN","price":577.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1186862.jpg?v=1782877417"},{"product_id":"heil-pressure-switch-for-wpg4244040lka1-oem-tubing-air-switch-ships-today","title":"Heil Pressure Switch for WPG4244040LKA1 — OEM Tubing Air Switch | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM tubing pressure switch (Part No. 1178417) for the ICP\/Tempstar\/Heil model WPG4244040LKA1. The pressure switch is a safety device that confirms the draft inducer is moving the proper volume of combustion air before the furnace is allowed to ignite. When the inducer runs, it creates negative pressure sensed through the connected tubing; the switch contacts close to prove draft and let the ignition sequence proceed. If venting is blocked, the inducer is weak, or the tubing is cracked or plugged, the switch stays open and the furnace will not fire. Common symptoms include a furnace that runs the inducer but never ignites, a pressure-switch lockout fault code, short cycling, or a switch stuck open or closed.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178417\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTubing Air-Proving Pressure Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCombustion Draft Verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace \/ Inducer Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the OEM replacement for ICP\/Tempstar\/Heil model WPG4244040LKA1. This tubing pressure switch is used across many gas furnaces in the same brand family. Match the part number and the switch's pressure setpoint stamped on the housing before ordering, since setpoints vary by furnace input and configuration.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace control\/inducer access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the tubing routing and electrical terminals before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Pull the sensing tube off the port, disconnect the spade terminals, and unscrew the old switch from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new switch, reconnect the wiring and sensing tube per your photo, ensuring the tube has no kinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then confirm the switch proves on inducer start and the furnace completes a normal heat cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInducer runs but the furnace never ignites\u003c\/li\u003e\n\u003cli\u003eControl board reports a pressure-switch open\/closed fault\u003c\/li\u003e\n\u003cli\u003eFurnace short cycles on the ignition attempt\u003c\/li\u003e\n\u003cli\u003eSwitch fails to open or close when tested with a manometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021520191859,"sku":"1178417","price":36.34,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209681267,"sku":"1178417-GEN","price":27.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-pressure-switch-single-1178417.jpg?v=1782877413"},{"product_id":"heil-40va-transformer-for-wpg3604130rkc1-208-230v-to-24v-w-barrier-ships-today","title":"Heil 40VA Transformer for WPG3604130RKC1 — 208\/230V to 24V w\/ Barrier | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM control transformer kit for the ICP\/Tempstar\/Heil model WPG3604130RKC1, including the 40VA transformer (Part No. 1173691) and its 24V terminal barrier (Part No. 1178431). The transformer steps the unit's 208\/230-volt primary line voltage down to the 24-volt secondary that powers the control board, thermostat, contactor coil, gas valve, and other low-voltage components. Rated at 40VA, it supplies enough capacity for the full low-voltage control circuit. When a transformer fails — usually from a shorted secondary wire or an overloaded control circuit — the entire 24V system goes dead. Symptoms include a blank thermostat, no response to heat or cool calls, a tripped low-voltage fuse, or a transformer that is hot, buzzing, or visibly burned.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1173691 (Transformer), 1178431 (24V Barrier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eStep-Down Control Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e208\/230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the OEM replacement for ICP\/Tempstar\/Heil model WPG3604130RKC1. This 40VA 208\/230V-to-24V transformer is used across many furnaces, air handlers, and package units in the same brand family. Confirm the part number, VA rating, and primary voltage against your existing transformer before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and unit disconnect, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical\/control access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the primary and secondary wiring and barrier terminals before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the line-voltage primary leads and 24V secondary leads, then unbolt the old transformer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new transformer and barrier, matching the primary tap to your supply voltage, and reconnect each lead per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify a steady 24 VAC at the secondary and normal thermostat and control operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlank thermostat and no 24V control power\u003c\/li\u003e\n\u003cli\u003eSystem won't respond to any heat or cool call\u003c\/li\u003e\n\u003cli\u003eRepeatedly blown low-voltage fuse\u003c\/li\u003e\n\u003cli\u003eTransformer is buzzing, overheating, or visibly burned\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021520224627,"sku":"1178431","price":41.54,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047208960371,"sku":"1178431-GEN","price":31.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-transformer-control-1178431.jpg?v=1782877373"},{"product_id":"heil-hot-surface-igniter-for-wpg3362090rkb1-oem-ignition-assembly-ships-today","title":"Heil Hot Surface Igniter for WPG3362090RKB1 — OEM Ignition Assembly | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter assembly (Part No. 1175974) provides the ignition source for the gas-heat section of the ICP\/Heil\/Tempstar WPG3362090RKB1 packaged gas\/electric unit. On each heat call, the control board sends voltage to the igniter, which glows red-hot to light the burners. As a brittle silicon-carbide or silicon-nitride element, it is one of the most common furnace failure points — it weakens with every cycle and eventually cracks. Symptoms of a failed igniter include no heat, the blower running with cold air, repeated lockouts, or a glow that never appears. This complete igniter assembly ships with the bracket and lead for a clean, direct replacement.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1175974\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the ICP\/Heil\/Tempstar WPG3362090RKB1 packaged gas\/electric unit and related WPG3 series equipment using igniter assembly 1175974. Confirm your part number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the unit disconnect and breaker, verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace\/burner section service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting position and wiring connector before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter lead, remove the mounting screw, and carefully withdraw the brittle element without touching the ceramic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter assembly (handle by the bracket only), reconnect the lead, and confirm proper position over the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for heat, and verify the igniter glows and the burners light.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat and no visible glow on a heat call\u003c\/li\u003e\n\u003cli\u003eBlower runs but only cold air comes out\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021531267443,"sku":"1175974","price":48.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209255283,"sku":"1175974-GEN","price":36.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1175974.jpg?v=1782877389"},{"product_id":"heil-hsi-flame-sensor-bracket-nat-propane-for-hemi100-hemi110-hemi130-furnace-ships-today","title":"Heil HSI Flame Sensor Bracket Nat\/Propane for HEMI100 HEMI110 HEMI130 Furnace — Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine Heil OEM flame sensor bracket (Part #79886) for HSI (Hot Surface Ignition) furnaces configured for Natural Gas or Propane (Nat\/Pro). The bracket holds the flame sensor rod in precise position over the burner so the control board can confirm flame is present after ignition. When the bracket is corroded, cracked, or warped from heat cycling, the sensor drifts out of the flame envelope — the board reads a weak or absent microamp signal and shuts the gas valve as a safety lockout. Symptoms include the furnace lighting then dropping out after 3–7 seconds, repeated short-cycling, and flame-sense fault codes. Replacing the bracket restores correct sensor geometry and a stable flame-rectification signal.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e79886\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eFlame Sensor Bracket (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHeil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural Gas \/ Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Exact-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirectly fits Heil HEMI-series modular furnaces including HEMI100, HEMI110, and HEMI130. As an OEM bracket it locates the flame sensor exactly as the factory intended for these HSI Nat\/Pro models.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and shut off the gas. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the flame sensor and bracket position and any wiring before removing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Pull the flame sensor lead, unscrew the old bracket from the burner assembly, and lift it out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new bracket, transfer the flame sensor, and reconnect the sensor lead per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat call, and confirm a steady flame with no lockout.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace ignites then shuts down within seconds (flame-sense failure)\u003c\/li\u003e\n\u003cli\u003eRepeated short-cycling on a heat call\u003c\/li\u003e\n\u003cli\u003eVisible corrosion, cracking, or heat distortion on the bracket\u003c\/li\u003e\n\u003cli\u003eSensor rod no longer sits in the flame path\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Heil","offers":[{"title":"OEM","offer_id":63027184337267,"sku":"79886","price":23.4,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209648499,"sku":"79886-GEN","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-79886.jpg?v=1782877411"},{"product_id":"heil-sectional-ignitor-bracket-for-hemi40-hemi50-hemi100-hemi110-hemi130-furnace-ships-today","title":"Heil Sectional Ignitor Bracket for HEMI40 HEMI50 HEMI100 HEMI110 HEMI130 Furnace — Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine Heil OEM ignitor bracket (Part #80184) is the sectional-style mounting bracket that holds the hot surface igniter in correct alignment with the burner on Heil HEMI furnaces. The bracket sets the igniter's gap and position so it glows directly in the gas stream for reliable light-off. Over many heating cycles the thin steel bracket can crack, sag, or corrode, letting the igniter drift away from the burner port. The result is delayed ignition, a 'whoomp' on light-off, repeated ignition retries, or hard lockout. Installing a fresh bracket re-establishes factory igniter geometry and restores clean, on-time ignition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e80184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIgnitor Bracket (Sectional, HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHeil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Exact-Fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits Heil HEMI modular furnaces including HEMI40, HEMI50, HEMI100, HEMI110, and HEMI130. The sectional design matches the factory burner assembly on these models.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and shut off the gas. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter and bracket position before disassembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Carefully detach the hot surface igniter (it is brittle), unbolt the old bracket from the burner section, and remove it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new bracket and reinstall the igniter, handling the ceramic element only by its base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm prompt, even light-off.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDelayed ignition or a 'whoomp' at light-off\u003c\/li\u003e\n\u003cli\u003eRepeated ignition retries before the burner lights\u003c\/li\u003e\n\u003cli\u003eIgniter visibly out of position or loose\u003c\/li\u003e\n\u003cli\u003eCracked, sagging, or corroded bracket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Heil","offers":[{"title":"OEM","offer_id":63027184370035,"sku":"80184","price":24.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209779571,"sku":"80184-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-80184.jpg?v=1782877415"},{"product_id":"heil-hot-surface-igniter-kit-for-wfmr045a036b3-with-bracket-ships-today","title":"Heil Hot Surface Igniter Kit for WFMR045A036B3 — with Bracket | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter assembly for the ICP\/Tempstar\/Heil WFMR045A036B3 furnace includes the igniter (part #1176919), its mounting bracket (part #1183455), and the snap-in HSI valve hardware (part #1176929, ref 36J24618). The igniter glows white-hot to light the gas at the burners on each call for heat. These ceramic elements are brittle and wear out — a cracked or worn igniter is the single most common cause of a no-heat call. Symptoms include the furnace clicking but never lighting, repeated ignition lockouts, or a glow that never reaches full brightness.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1176919\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket Part Number\u003c\/td\u003e\n\u003ctd\u003e1183455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve\/Snap Hardware\u003c\/td\u003e\n\u003ctd\u003e1176929 (36J24618)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil WFMR045A036B3 furnace. The included bracket and snap-in hardware ensure correct positioning of the igniter over the burner.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and its wiring harness before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and unscrew the old igniter and bracket. Handle only by the ceramic base — never touch the glow element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new bracket and igniter, align it over the burner per your photo, and reconnect the harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition cycle to confirm a clean, full-brightness light.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace clicks and the inducer runs but the burners never light\u003c\/li\u003e\n\u003cli\u003eVisible cracks or a broken igniter element\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or short cycling on startup\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim or unevenly instead of bright white\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027239551347,"sku":"1183455","price":54.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209582963,"sku":"1183455-GEN","price":42.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1183455.jpg?v=1782877406"},{"product_id":"icp-tempstar-heil-40a-contactor-for-wch3604gkc100-24v-coil-ships-today","title":"ICP Tempstar Heil 40A Contactor for WCH3604GKC100 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine 40-amp contactor for the ICP \/ Tempstar \/ Heil WCH3604GKC100 condensing unit. The contactor is the electrically operated switch that sends line voltage to the compressor and condenser fan motor whenever the 24V control circuit calls for cooling or heat-pump operation. Its 24-volt coil pulls the contacts closed; pitted, welded, or chattering contacts are one of the most common causes of a unit that hums but won't start, or that won't shut off. OEM part 1176763 is the direct factory replacement rated at 40A.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \u0026amp; Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit for the ICP\/Tempstar\/Heil WCH3604GKC100 and equivalent condensing units using a 40A, 24V-coil definite-purpose contactor. Confirm pole count and coil voltage against your existing part before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and verify zero voltage with a multimeter at the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control-access service panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Move wires one at a time to the new contactor, or label them; then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect line, load, and 24V coil wires exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and call for cooling; confirm the contactor pulls in cleanly and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit hums but compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003ePitted, burnt, or welded contacts visible on inspection.\u003c\/li\u003e\n\u003cli\u003eChattering or buzzing from the contactor.\u003c\/li\u003e\n\u003cli\u003eSystem won't shut off because contacts are stuck closed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027251544435,"sku":"1176763","price":80.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047720206707,"sku":"1176763-GEN","price":80.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_ce7d8e72-f4a9-42f6-9485-c5b4264f3677.jpg?v=1782895959"},{"product_id":"icp-tempstar-heil-40a-contactor-for-wch3604gkb1-24v-coil-ships-today","title":"ICP Tempstar Heil 40A Contactor for WCH3604GKB1 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine 40-amp contactor for the ICP \/ Tempstar \/ Heil WCH3604GKB1 condensing unit. The contactor is the electrically operated switch that feeds line voltage to the compressor and condenser fan motor when the 24V control circuit calls for operation. A 24-volt coil pulls the contacts closed; pitted, welded, or chattering contacts commonly cause a unit that hums but won't start or won't shut off. OEM part 1176763 is the direct factory replacement rated at 40A.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \u0026amp; Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit for the ICP\/Tempstar\/Heil WCH3604GKB1 and equivalent condensing units using a 40A, 24V-coil definite-purpose contactor. Confirm pole count and coil voltage against your existing part before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and verify zero voltage with a multimeter at the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control-access service panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Move wires one at a time to the new contactor, or label them; then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect line, load, and 24V coil wires exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and call for cooling; confirm the contactor pulls in cleanly and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit hums but compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003ePitted, burnt, or welded contacts visible on inspection.\u003c\/li\u003e\n\u003cli\u003eChattering or buzzing from the contactor.\u003c\/li\u003e\n\u003cli\u003eSystem won't shut off because contacts are stuck closed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027251577203,"sku":"1176763","price":80.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047720108403,"sku":"1176763-GEN","price":80.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_66beab7f-60d8-430a-8a80-4776762b1b9a.jpg?v=1782895957"},{"product_id":"heil-hot-surface-igniter-electrode-for-rgs300htfa0aaaa-direct-spark-ignition-ships-today","title":"Heil Hot Surface Igniter Electrode for RGS300HTFA0AAAA — Direct-Spark Ignition | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM igniter electrode (part 1179966) is the component that ignites the gas at the burner in your ICP \/ Tempstar \/ Heil RGS300HTFA0AAAA furnace package unit. On an ignition cycle the control board energizes the electrode to create the spark\/heat that lights the main burner; the same assembly is also used by the control to confirm flame. When the electrode cracks, fouls, or wears out, the furnace will lock out on failed ignition — you'll typically hear the gas valve open and the inducer run, but no flame, followed by a retry-and-lockout sequence. Replacing this inexpensive wear part restores reliable heating and prevents nuisance no-heat calls during cold weather.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIgniter \/ Ignition Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBurner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eRGS300HTFA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit replacement for the ICP\/Heil\/Tempstar RGS300HTFA0AAAA model and related RGS-series gas package units using the same burner assembly. Confirm the mounting bracket and lead orientation match your existing electrode.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off the gas at the valve and disconnect electrical power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment \/ service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the electrode position and wire routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the ignition lead and unfasten the electrode mounting screw(s), then withdraw the old electrode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new electrode at the correct gap to the burner, fasten the bracket, and reconnect the lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, run a heat cycle, and verify clean ignition on the first try.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace locks out with no flame after the inducer and gas valve activate\u003c\/li\u003e\n\u003cli\u003eVisible cracks, carbon buildup, or corrosion on the electrode\u003c\/li\u003e\n\u003cli\u003eDelayed ignition or a small \"poof\" at light-off\u003c\/li\u003e\n\u003cli\u003eRepeated ignition retries before lockout on a heat call\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027280478579,"sku":"1179966","price":37.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047208993139,"sku":"1179966-GEN","price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966.jpg?v=1782877375"},{"product_id":"heil-hot-surface-igniter-for-rgs243hraa0aaaa-oem-ignitor-electrode-ships-today","title":"Heil Hot Surface Igniter for RGS243HRAA0AAAA — OEM Ignitor Electrode | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter electrode lights the burners on your ICP Tempstar Heil RGS243HRAA0AAAA gas furnace. On each call for heat the control board energizes the igniter, which glows red-hot and ignites the gas as the valve opens. Igniters are brittle and degrade with every heating cycle — cracks, erosion, or a break leave the furnace with a working blower and gas valve but no flame, often producing a furnace that ignites intermittently or locks out after several failed tries. This direct-fit electrode restores dependable ignition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter (Ignitor Electrode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP Tempstar Heil RGS243HRAA0AAAA gas furnace and related RGS243-series models. Verify the igniter mounting and connector style match your existing part.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position, bracket, and wire routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter — handle only by the ceramic base, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, reconnect the plug, and avoid touching the glow element with bare hands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the igniter glows and the burners light on a heat call.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo glow on a call for heat\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several ignition attempts\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the igniter element\u003c\/li\u003e\n\u003cli\u003eBlower and gas valve work but no flame\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027290046835,"sku":"1179966","price":38.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209189747,"sku":"1179966-GEN","price":29.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_2a5640b0-a2a0-485e-ba6f-08ed286b3f77.jpg?v=1782877387"},{"product_id":"icp-heil-tempstar-igniter-electrode-for-rgs240hdea0aaaa-oem-direct-spark-ships-today","title":"ICP Heil Tempstar Igniter Electrode for RGS240HDEA0AAAA — OEM Direct-Spark | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM igniter electrode (part 1179966) provides the high-voltage spark that lights the burners in your ICP \/ Heil \/ Tempstar RGS240HDEA0AAAA gas furnace. On a heat call, the control board sends a spark across the electrode gap to ignite gas at the burner; the same or a paired electrode often doubles as the flame-sensing rod. A cracked ceramic insulator, eroded electrode tip, carbon buildup, or an out-of-spec gap causes failed ignition, repeated lockouts, delayed light-off, or rough flame rollout. Installing a fresh OEM electrode with the correct gap restores fast, reliable ignition every cycle.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIgniter \/ spark electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDirect-spark burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulator\u003c\/td\u003e\n\u003ctd\u003eCeramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP \/ Heil \/ Tempstar RGS240HDEA0AAAA and related ICP-family gas furnaces. Verify the electrode bracket, rod length, and gap against your existing part before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter before working near the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the electrode position, gap, and ignition lead before removing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the high-voltage lead and unfasten the old electrode from the burner bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new OEM electrode, set the manufacturer-specified gap, and reconnect the lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then confirm a clean spark and prompt burner ignition.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts.\u003c\/li\u003e\n\u003cli\u003eCracked or chipped ceramic insulator.\u003c\/li\u003e\n\u003cli\u003eWeak, erratic, or no visible spark at the gap.\u003c\/li\u003e\n\u003cli\u003eDelayed ignition with a noticeable gas smell or rollout.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027313541491,"sku":"1179966","price":38.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047603585395,"sku":"1179966-GEN","price":29.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_3f6db81f-cbf3-483d-bb9d-72df06988d49.jpg?v=1782891438"},{"product_id":"icp-heil-tempstar-furnace-control-board-kit-for-rgs240hdea0aaaa-oem-replacement-ships-today","title":"ICP Heil Tempstar Furnace Control Board Kit for RGS240HDEA0AAAA — OEM Replacement | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM control board kit (part 1183618) is the integrated furnace control (IFC) that orchestrates every heat and cool cycle in your ICP \/ Heil \/ Tempstar RGS240HDEA0AAAA furnace. It manages the ignition sequence, inducer and blower timing, gas valve control, and the safety interlocks for limit switches, pressure switches, and flame sense. Supplied as a kit, it includes the mounting hardware and instructions needed for a clean swap. When the board fails you may see a dead unit, no inducer or blower, flashing diagnostic fault codes, short cycling, or ignition lockouts that persist after the igniter and sensors check out. Replacing a failed board with the correct OEM kit restores full, code-compliant operation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1183618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated furnace control board kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd\u003eIgnition, inducer, blower, gas valve, safeties\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eBoard, mounting hardware, instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP \/ Heil \/ Tempstar RGS240HDEA0AAAA and related ICP-family furnaces. Match the board part number and connector layout to your existing control before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower\/control compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every harness connection and note any DIP switch or jumper settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug each connector, unfasten the old board, and transfer it from its standoffs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new OEM board, replicate the original switch\/jumper settings, and reconnect every harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and run a full heat cycle, confirming proper ignition, blower timing, and no fault codes.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace is completely dead with no diagnostic LED.\u003c\/li\u003e\n\u003cli\u003ePersistent flashing fault codes after other parts check out.\u003c\/li\u003e\n\u003cli\u003eInducer or blower fails to energize on a call.\u003c\/li\u003e\n\u003cli\u003eShort cycling or ignition lockouts not traced to igniter\/sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027313574259,"sku":"1183618","price":246.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047603552627,"sku":"1183618-GEN","price":189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1183618_bd0e35a1-2e9e-453b-b334-645c07a62ca0.jpg?v=1782891436"},{"product_id":"heil-hot-surface-igniter-for-rgs214hdaa0aaaa-direct-replacement-electrode-ships-today","title":"Heil Hot Surface Igniter for RGS214HDAA0AAAA — Direct-Replacement Electrode | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter electrode (P\/N 1179966) is the component that lights the burners in your ICP RGS214HDAA0AAAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows red-hot and ignites the gas as the valve opens. Igniters are a wear item — the silicon carbide or nitride element becomes brittle over years of thermal cycling and eventually cracks. The most common failure symptom is a furnace that runs the inducer and blower but never produces heat, often locking out after several failed ignition attempts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter \/ Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP RGS214HDAA0AAAA and the broader ICP family of gas furnaces sold under Tempstar, Heil, and Comfortmaker labels. Verify the mounting bracket and connector style against your existing igniter before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off the furnace at the switch and breaker, close the gas, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and its wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw; handle only by the ceramic base — never touch the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new igniter so the element aligns with the burner flame path, secure the screw, and reconnect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and gas, start a heat cycle, and confirm the igniter glows and burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace inducer and blower run but no heat is produced.\u003c\/li\u003e\n\u003cli\u003eCracked, chipped, or visibly broken igniter element.\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows during a heat call.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027316392307,"sku":"1179966","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209156979,"sku":"1179966-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_bf417774-cbbd-4bb1-97d7-e7045b41525d.jpg?v=1782877384"},{"product_id":"icp-tempstar-heil-2-pole-30a-contactor-for-rgs210sfea0aaaa-24v-coil-ships-today","title":"ICP Tempstar Heil 2-Pole 30A Contactor for RGS210SFEA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM 2-pole, 30-amp contactor (part 1171554) has a 24V coil and is used in ICP, Tempstar, and Heil equipment associated with the RGS210SFEA0AAAA. A contactor is an electrically controlled switch: when the 24V control circuit energizes the coil, the contacts close and pass line voltage to the compressor and\/or condenser fan. Over thousands of cycles the contacts arc, pit, and can weld shut or fail to close. Symptoms of a failing contactor include a system that won't start, a humming or buzzing contactor, contacts that stick closed (system runs constantly), or visible burning and pitting on the contact faces. Replacing a worn contactor restores clean switching and protects downstream motor windings.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e30 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eBuilt for the ICP \/ Tempstar \/ Heil RGS210SFEA0AAAA and other units that specify contactor part 1171554. Confirm pole count, amp rating, and 24V coil against your existing contactor before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical access\/service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label each lead, then unbolt the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire exactly as photographed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in on a call and drop out cleanly when satisfied.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSystem won't start or starts intermittently\u003c\/li\u003e\n\u003cli\u003eLoud humming or buzzing from the contactor\u003c\/li\u003e\n\u003cli\u003eContacts stuck closed — unit runs nonstop\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or melted contact faces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027325272435,"sku":"1171554","price":35.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047720042867,"sku":"1171554-GEN","price":26.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_1bf34653-537d-4e93-8b91-a39cf3495ca6.jpg?v=1782895954"},{"product_id":"icp-tempstar-heil-ignitor-electrode-for-rgs210sfea0aaaa-oem-1179966-ships-today","title":"ICP Tempstar Heil Ignitor Electrode for RGS210SFEA0AAAA — OEM 1179966 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM ignitor electrode, part number 1179966, for ICP, Tempstar, and Heil gas furnaces including the RGS210SFEA0AAAA. The ignition electrode delivers the spark (and\/or flame-sensing path) at the burner that lights the gas on a call for heat. When the electrode cracks, the tip erodes, the gap drifts out of spec, or the ceramic insulator carbons over, the furnace will fail to light, lock out after several trial-for-ignition attempts, or short-cycle on ignition faults. Because the electrode sits directly in the burner flame, it is a normal wear item and a frequent no-heat callback. Installing a fresh OEM electrode restores a reliable, correctly-gapped ignition source.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIgnitor Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eRGS210SFEA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP \/ Tempstar \/ Heil RGS210SFEA0AAAA and related RGS-series gas furnaces that call out electrode part 1179966. Verify against your unit's burner assembly before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off the gas, disconnect power at the switch and breaker, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the electrode position, wire routing, and gap before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the ignition lead, unscrew the electrode bracket, and withdraw the old electrode from the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new electrode, confirm correct gap and flame alignment, and reconnect the ignition lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition sequence to confirm a clean light-off.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace won't light on a call for heat\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts after several attempts\u003c\/li\u003e\n\u003cli\u003eCracked ceramic insulator or eroded electrode tip\u003c\/li\u003e\n\u003cli\u003eShort-cycling tied to ignition or flame-sense faults\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027325305203,"sku":"1179966","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047720862067,"sku":"1179966-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_22cd73d2-47e9-4b9f-aac5-1a4048c0e775.jpg?v=1782895963"},{"product_id":"icp-tempstar-heil-furnace-control-board-kit-for-rgs210sfea0aaaa-oem-1183618-ships-today","title":"ICP Tempstar Heil Furnace Control Board Kit for RGS210SFEA0AAAA — OEM 1183618 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM control board kit, part number 1183618, is the integrated furnace control (IFC) for ICP, Tempstar, and Heil gas furnaces such as the RGS210SFEA0AAAA. The control board is the brain of the furnace: it manages the ignition sequence, sequences the inducer and blower, monitors flame and limit\/pressure safeties, and drives the gas valve. Supplied as a kit, it includes the board and the hardware needed for a complete replacement. A failed board typically shows as no response on a call for heat, no inducer or blower operation, error flash codes, intermittent lockouts, or scorched\/blown traces and relays on the board itself. Power surges, moisture, and aging relays are common causes of failure.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1183618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated Furnace Control Board Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eRGS210SFEA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP \/ Tempstar \/ Heil RGS210SFEA0AAAA and related RGS-series furnaces that call out control board kit 1183618. Match the part number and connector layout to your existing board before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace control\/blower compartment panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every connector and wire on the old board before unplugging anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug each harness, release the board standoffs\/screws, and lift out the old control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, then reconnect every harness exactly as photographed; set any dip switches\/jumpers to match.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and run a full heat cycle, verifying inducer, ignition, gas valve, and blower sequence and any flash codes.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo response from the furnace on a call for heat\u003c\/li\u003e\n\u003cli\u003eInducer or blower won't run, or runs continuously\u003c\/li\u003e\n\u003cli\u003eError\/diagnostic flash codes pointing to the control\u003c\/li\u003e\n\u003cli\u003eVisible burnt traces, blown relays, or scorching on the board\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027325337971,"sku":"1183618","price":201.5,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047720272243,"sku":"1183618-GEN","price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1183618_2f00133c-8105-499a-be4b-6e624bf9af93.jpg?v=1782895961"},{"product_id":"heil-hot-surface-igniter-for-rgs150lfaa0akaa-with-wiring-kit-ships-today","title":"Heil Hot Surface Igniter for RGS150LFAA0AKAA — with Wiring Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM hot surface igniter kit fits the ICP \/ Tempstar \/ Heil RGS150LFAA0AKAA gas furnace. The igniter is a brittle ceramic element that glows red-hot when the control board energizes it, lighting the burners at the start of each heat cycle. Over thousands of cycles the element develops hairline cracks and eventually opens, leaving you with a furnace that runs the inducer and blower but never produces heat. This listing includes OEM igniter 1171306 and the matching igniter wiring kit 1188370, so you get both the element and the harness\/connector needed for a clean replacement. Typical failure symptoms are no ignition, the furnace locking out after several trial-for-ignition attempts, or a visibly cracked igniter that no longer glows.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter) + 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element and wiring\/connector kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFactory replacement for the ICP RGS150LFAA0AKAA and shared across many Tempstar, Heil, Comfortmaker, and Day \u0026amp; Night furnaces that use this hot surface igniter platform. Verify your existing igniter mounting bracket and connector against the kit before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter — handle the new one by the ceramic base only, never the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, route the new wiring kit, and reconnect the harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power and watch a full ignition cycle to confirm the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs inducer and blower but burners never light\u003c\/li\u003e\n\u003cli\u003eControl board locks out after repeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eIgniter shows visible cracks or no longer glows orange\u003c\/li\u003e\n\u003cli\u003eIntermittent no-heat calls that clear after a reset\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027387302259,"sku":"1171306","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209124211,"sku":"1171306-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_1f62e7ae-cfb0-4a79-bf9b-2c8648627a94.jpg?v=1782877382"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs150ldcb0aaaa-with-wiring-harness-ships-today","title":"Heil Hot Surface Igniter Kit for RGS150LDCB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (part 1171306) and matching igniter wiring kit (part 1188370) provide reliable ignition for the ICP\/Tempstar\/Heil RGS150LDCB0AAAA gas furnace. On each heat call the furnace control board sends line voltage to the igniter, which glows red-hot to ignite the gas at the burners. Igniters are a wear item — the silicon carbide or silicon nitride element grows brittle with thousands of heating cycles and eventually cracks, leaving the furnace unable to light. The included wiring kit ensures the connector and harness match the furnace control, avoiding the melted or corroded plugs that often accompany an aged igniter.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Burner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS150LDCB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the factory replacement igniter assembly for the ICP\/Tempstar\/Heil RGS150LDCB0AAAA and other same-generation Carrier-family gas furnaces using a hot surface ignition system. The bundled wiring kit lets you replace the harness at the same time when the original connector is heat-damaged.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and electrical power, then verify zero voltage with a multimeter before servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and the wiring harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the fragile igniter — never touch the element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter so the element sits in the burner flame path, then connect the new wiring kit to the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light within the normal ignition sequence.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks and the inducer runs but the burners never light\u003c\/li\u003e\n\u003cli\u003eIgniter shows no glow or only a dim, uneven glow\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element\u003c\/li\u003e\n\u003cli\u003eControl board locks out after several failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027398115699,"sku":"1171306","price":51.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209517427,"sku":"1171306-GEN","price":39.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_fefbe41e-df04-426e-a44e-56bc48345600.jpg?v=1782877404"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs150hfcb0aaaa-with-wiring-harness-ships-today","title":"Heil Hot Surface Igniter Kit for RGS150HFCB0AAAA — with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (HSI) is what lights the burners on your ICP \/ Tempstar \/ Heil RGS150HFCB0AAAA gas furnace. On a call for heat, the control board sends 120V to the igniter, which glows white-hot and ignites the gas as the valve opens. We bundle the igniter (OEM 1171306) with the matching igniter wiring kit (OEM 1188370) so you replace the brittle, heat-stressed element and its connector together — the most reliable repair. Hot surface igniters are fragile and degrade with every heating cycle. Common failure symptoms include no ignition and the furnace locking out, a cracked or visibly broken element, the igniter glowing but the burners never lighting, or repeated short-cycling on ignition failure.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter) + 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirectly fits the ICP\/Tempstar\/Heil RGS150HFCB0AAAA gas furnace and other models sharing the same igniter assembly. The included wiring kit ensures a clean connection to the furnace control board.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wire routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw; handle the old element by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element surface, then connect the new wiring kit to the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace locks out with no ignition\u003c\/li\u003e\n\u003cli\u003eCracked, chipped, or visibly broken igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter glows but burners never light\u003c\/li\u003e\n\u003cli\u003eRepeated short-cycling on ignition failure\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027415613811,"sku":"1171306","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209484659,"sku":"1171306-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_c093e2ff-e37e-488c-9238-277f8fe82083.jpg?v=1782877402"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs121ltab0aaaa-oem-ignitor-wiring-ships-today","title":"Heil Hot Surface Igniter Kit for RGS121LTAB0AAAA — OEM Ignitor + Wiring | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM \u003cstrong\u003ehot surface igniter kit\u003c\/strong\u003e for the ICP \/ Heil \/ Tempstar \u003cstrong\u003eRGS121LTAB0AAAA\u003c\/strong\u003e gas furnace includes the igniter element (part #1171306) and the matching igniter wiring kit\/harness (part #1188370). On each call for heat, the control board sends voltage to the igniter, which glows hot enough to ignite the gas at the burners. Hot surface igniters are a wear item — the brittle silicon-carbide\/nitride element degrades with every heating cycle and eventually cracks, producing a no-heat condition where the inducer and gas valve sequence but the burners never light. Replacing the element together with a fresh wiring harness restores reliable ignition.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter with Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eGenuine OEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP\/Heil\/Tempstar RGS121LTAB0AAAA gas furnace and related RGS121 series units using the same hot surface ignition system. Confirm igniter mounting and connector style against your original before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter. Never touch the new igniter element with bare fingers — skin oils shorten its life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and the wiring\/connector routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw(s), and carefully lift out the cracked element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter in the same position, connect the new wiring kit, and route the harness clear of hot surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat call, and confirm the igniter glows and the burners light within the normal trial-for-ignition period.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace runs the ignition sequence but burners never light (no-heat).\u003c\/li\u003e\n\u003cli\u003eVisible crack, chip, or broken tip on the igniter element.\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow, or glows weakly\/unevenly.\u003c\/li\u003e\n\u003cli\u003eFrayed, brittle, or melted igniter wiring\/connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027470631283,"sku":"1171306","price":41.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209451891,"sku":"1171306-GEN","price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_d37acb08-467c-4931-ac87-2e67de50614c.jpg?v=1782877400"},{"product_id":"heil-hot-surface-igniter-for-rgs121lfab0aaaa-with-wiring-kit-ships-today","title":"Heil Hot Surface Igniter for RGS121LFAB0AAAA — With Wiring Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (part #1171306) is the component that ignites the burners on your ICP Tempstar Heil RGS121LFAB0AAAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows white-hot to light the gas as it flows across the burners. Hot surface igniters are fragile and degrade with every cycle — the silicon carbide or nitride element eventually cracks, oxidizes, or breaks, leaving the furnace unable to light. This listing includes the matching igniter wiring kit (part #1188370) for a clean, reliable connection. Typical failure symptoms are no heat, a furnace that clicks and tries to start but never ignites, repeated lockouts, or a visibly cracked or broken igniter element.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Kit\u003c\/td\u003e\n\u003ctd\u003e1188370 (Igniter Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit OEM replacement for the ICP Tempstar Heil RGS121LFAB0AAAA and related RGS-series furnaces using OEM igniter 1171306. The bundled wiring kit 1188370 ensures a correct, sealed connection to the furnace harness.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and remove the mounting screw; handle the old igniter by its base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter (never touch the element), attach the wiring kit, and seat the connector firmly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition cycle to confirm a steady glow and burner light-off.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat — furnace tries to start but burners never light\u003c\/li\u003e\n\u003cli\u003eVisibly cracked, chipped, or broken igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter no longer glows during a heat call\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or short-cycling on heat\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027488620915,"sku":"1171306","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209091443,"sku":"1171306-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_1ce7afcb-06e7-409a-9faa-8850e81db16b.jpg?v=1782877380"},{"product_id":"heil-hot-surface-igniter-for-rgs121htcb0aaa-with-wiring-kit-ships-today","title":"Heil Hot Surface Igniter for RGS121HTCB0AAA — With Wiring Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter (OEM 1171306) ignites the burners on your ICP Tempstar\/Heil RGS121HTCB0AAA gas furnace. On each heat call, 120V power heats the igniter element to glowing temperature so it lights the gas as the valve opens. The matching igniter wiring kit (OEM 1188370) is included to ensure a clean, correct electrical connection. Hot surface igniters are a wear item — the brittle silicon-carbide or silicon-nitride element gradually degrades and eventually cracks, leaving you with no heat. A failed igniter is the single most common no-heat furnace complaint, and replacement restores reliable ignition.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP Tempstar\/Heil RGS121HTCB0AAA and related RGS-series gas furnaces using a 120V hot surface igniter. The included wiring kit adapts the connection for a secure fit.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wire routing before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and remove the mounting screw; handle the fragile element by the ceramic base only — never touch the hot surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter using the included wiring kit, keeping fingers off the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and lights the burners.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace blower runs but produces no heat\u003c\/li\u003e\n\u003cli\u003eVisibly cracked or broken igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter never glows during the ignition sequence\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated failed ignition attempts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027503595891,"sku":"1171306","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209025907,"sku":"1171306-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306.jpg?v=1782877377"},{"product_id":"heil-hot-surface-igniter-with-wiring-kit-for-rgs120lrcb0aaa-oem-ignitor-ships-today","title":"Heil Hot Surface Igniter with Wiring Kit for RGS120LRCB0AAA — OEM Ignitor | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM hot surface igniter (part 1171306) bundled with its matched igniter wiring kit (part 1188370) for the ICP \/ Tempstar \/ Heil RGS120LRCB0AAA gas furnace. On a call for heat, the furnace control board sends line voltage to the igniter, which heats to a glowing temperature and lights the burner gas. Hot surface igniters are brittle and degrade over time — the element develops hairline cracks or hot spots until it can no longer reach ignition temperature. Including the wiring kit ensures the connector and leads are fresh, avoiding the intermittent no-ignition faults caused by a brittle or heat-damaged harness.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot surface igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace burner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP-family RGS120LRCB0AAA gas furnace and related ICP, Tempstar, Heil, and Comfortmaker furnaces using OEM igniter 1171306 with wiring kit 1188370. Verify your existing igniter part number and mounting bracket style before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position, bracket, and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out — handle only by the ceramic base, never the fragile element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter so the element sits in the burner flame path, install the new wiring kit, and reconnect the harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a heat cycle, and confirm the igniter glows and lights the burners promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace ignites no heat \/ igniter never glows\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or white hot spots on the element\u003c\/li\u003e\n\u003cli\u003eIntermittent ignition or repeated ignition lockouts\u003c\/li\u003e\n\u003cli\u003eBrittle, melted, or discolored igniter wiring or connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027544588659,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209615731,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_643029db-8b48-48c0-85a4-267fc016d469.jpg?v=1782877408"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs120lfbb0aaa-with-wiring-harness-ships-today","title":"Heil Hot Surface Igniter Kit for RGS120LFBB0AAA — with Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter kit for the ICP\/Tempstar\/Heil RGS120LFBB0AAA gas furnace includes the igniter element (part 1171306) and the matching igniter wiring kit (part 1188370). On a call for heat, the furnace control board sends line voltage to the igniter, which glows red-hot to light the gas at the burners. Because the brittle silicon-carbide or silicon-nitride element degrades with every heating cycle, the igniter is one of the most common furnace failure points. Symptoms of a failed igniter include no ignition, the furnace cycling on the limit, a cracked or visibly broken element, or an igniter that no longer glows. The included wiring kit ensures a clean OEM connection and avoids reusing brittle, heat-aged leads.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgniter Part Number\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Kit Part Number\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM replacement for the ICP\/Tempstar\/Heil\/Comfortmaker RGS120LFBB0AAA and related RGS-series gas furnaces. Handle the element only by its ceramic base — skin oils shorten igniter life.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch\/breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/control panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old element without touching the burners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter (handle by the base only), install the new wiring kit, and confirm proper position over the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and watch a full heat cycle to confirm the igniter glows and ignites the gas.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace fails to light on a call for heat\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weakly\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the element\u003c\/li\u003e\n\u003cli\u003eRepeated lockouts or short-cycling on the limit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027546095987,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209419123,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_3b51ec68-dee0-405c-ab22-ea4c70cc18bb.jpg?v=1782877398"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs102sfba0aaa-with-wiring-harness-ships-today","title":"Heil Hot Surface Igniter Kit for RGS102SFBA0AAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter kit for the ICP \/ Tempstar \/ Heil RGS102SFBA0AAA packaged gas\/electric unit includes the igniter element (part 1171306) and the matching igniter wiring kit\/harness (part 1188370). On a heat call, the control board energizes the igniter, which glows white-hot to light the burners. Hot surface igniters are a common failure point — the brittle silicon-carbide or silicon-nitride element cracks from thermal cycling, repeated handling, or moisture, and the lead wires and connector can overheat or corrode. Including the wiring kit ensures a clean electrical connection and prevents a no-heat callback caused by a damaged harness. Failure symptoms include no ignition, repeated ignition lockouts, a visibly cracked or no-longer-glowing igniter, and delayed or rough burner light-off.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter with Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBurner ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP \/ Tempstar \/ Heil RGS102SFBA0AAA packaged unit and related ICP-family furnaces using this hot surface igniter. Match the igniter mounting and connector to your original before ordering.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect electrical power and shut off the gas supply. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photo the igniter mounting and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter. Handle the new element only by its ceramic base — never touch the glow surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, route and plug in the new wiring kit, and confirm the element sits correctly over the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, start a heat cycle, and verify the igniter glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat — burners never ignite\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow or glows weakly\u003c\/li\u003e\n\u003cli\u003eVisible crack or break in the igniter element\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or delayed light-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027630113139,"sku":"1171306","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209353587,"sku":"1171306-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_5d131dea-754f-409f-9332-0f0ce5d4e2ee.jpg?v=1782877396"},{"product_id":"heil-hot-surface-igniter-kit-for-rgs091lsab0aaaa-with-wiring-harness-ships-today","title":"Heil Hot Surface Igniter Kit for RGS091LSAB0AAAA — With Wiring Harness | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (part number 1171306) with its matching wiring kit (part number 1188370) is the ignition source for your ICP Tempstar Heil RGS091LSAB0AAAA gas furnace. On a heat call the control board sends voltage to the igniter, which glows white-hot to light the burners. Igniters are brittle silicon-carbide or silicon-nitride elements that crack, develop hairline fractures, or simply wear out from thousands of heating cycles. The result is a furnace that clicks and tries to ignite but never lights, then locks out. Replacing the igniter — and the heat-stressed wiring connector with the included kit — restores reliable ignition.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (Igniter)\u003c\/td\u003e\n\u003ctd\u003e1171306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (Wiring Kit)\u003c\/td\u003e\n\u003ctd\u003e1188370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + Wiring Harness Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirectly fits ICP Tempstar Heil model RGS091LSAB0AAAA and related ICP-family gas furnaces using this hot surface igniter. The included wiring kit ensures a clean, heat-rated connection. Verify igniter mounting and connector style against your existing part before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner\/blower service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mount and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out — handle only by the ceramic base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, install the new wiring kit, and reconnect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace clicks and attempts ignition but burners never light.\u003c\/li\u003e\n\u003cli\u003eVisible cracks or breaks in the igniter element.\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow on a heat call.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after several failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027673301363,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047209320819,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_b4640387-a3a3-40c7-bed7-edb84764b5c9.jpg?v=1782877393"},{"product_id":"icp-hot-surface-igniter-for-rgs090staa0agaa-tempstar-heil-furnace-ships-today","title":"ICP Hot Surface Igniter for RGS090STAA0AGAA — Tempstar\/Heil Furnace | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM hot surface igniter (part #1171306) is the ignition source for the ICP \/ Tempstar \/ Heil RGS090STAA0AGAA 90,000 BTU gas furnace. On each call for heat the furnace control board energizes the igniter, which glows to roughly 2,000°F and lights the burner gas. This listing ships with the matching igniter wiring kit (part #1188370) so you have the harness and connector needed for a clean, code-correct replacement. A cracked element or open circuit is one of the most common no-heat failures on this furnace — symptoms include the igniter never glowing, glowing but the burners failing to light, or the furnace locking out after several ignition retries.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS090STAA0AGAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas furnace ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter + wiring kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit OEM replacement for the ICP\/Tempstar\/Heil RGS090STAA0AGAA gas furnace. The 1171306 igniter and 1188370 wiring kit are also used across many ICP-family RGS, NGS and comparable induced-draft furnace platforms — match your old part number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace blower\/burner service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wiring routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw, and lift the old igniter out without touching the silicon-nitride element with bare fingers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter, install the wiring kit, and reconnect the harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and cycle a call for heat; confirm the igniter glows and the burners light within the trial-for-ignition window.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIgniter never glows on a call for heat.\u003c\/li\u003e\n\u003cli\u003eVisible crack or hot spot in the element.\u003c\/li\u003e\n\u003cli\u003eFurnace ignites then locks out, or short-cycles on ignition failure.\u003c\/li\u003e\n\u003cli\u003eCold air from registers with the blower running but no flame.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027681395059,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047621968243,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_0c4300db-95cf-4189-90f2-cf1b0f09d52a.jpg?v=1782891971"}],"url":"https:\/\/nationalhvacparts.com\/collections\/heil.oembed?page=2","provider":"National HVAC Parts","version":"1.0","type":"link"}