{"title":"Heat Exchangers","description":null,"products":[{"product_id":"oem-goodman-heat-exchanger-for-gmp100-3-furnace-2921306s","title":"OEM Goodman Heat Exchanger for GMP100-3 Furnace — 2921306S","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 2921306S Heat Exchanger\u003c\/strong\u003e is a genuine OEM replacement for the \u003cstrong\u003eGoodman GMP100-3\u003c\/strong\u003e gas furnace. The heat exchanger is the heart of the furnace — it transfers heat from combustion gases to the circulating air stream while keeping flue products physically separated from your home's air. A cracked or corroded exchanger is a safety-critical failure that can allow carbon monoxide into the airflow, so it must be replaced with a correctly matched OEM part.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 2921306S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits Model:\u003c\/strong\u003e Goodman GMP100-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Heat Exchanger\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Type:\u003c\/strong\u003e 100,000 BTU-class Gas Furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Aluminized steel clamshell exchanger\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman (OEM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eHeat exchangers are one part where OEM is not optional. This factory unit matches the GMP100-3 burner alignment, cell geometry, and mounting exactly, ensuring proper flame impingement and thermal expansion behavior. Non-OEM exchangers risk misalignment, hot spots, and premature cracking. Genuine Goodman construction also protects any remaining furnace warranty.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eExpert \/ Professional Only\u003c\/strong\u003e — replacing a heat exchanger requires nearly full furnace disassembly, burner and manifold removal, and post-install combustion analysis. This is a safety-critical repair and should be completed by a licensed HVAC technician, followed by a CO test and draft verification.\u003c\/p\u003e\u003cp\u003eShut off gas and electrical power before any service. Confirm your furnace model and serial before ordering; contact info@nationalhvacparts.com for fitment help.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057148084595,"sku":"GOODMAN-2921306S","price":828.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-heat-exchanger-GMP100-1-1784494960216.jpg?v=1784494961"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acec800603axaa-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACEC800603AXAA — 0128F00006","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is a genuine OEM flue-venting component for the Goodman \u003cstrong\u003eACEC800603AXAA\u003c\/strong\u003e gas furnace and compatible Goodman\/Amana models. This stamped transition piece channels hot combustion products from the heat exchanger collector into the vent connector, maintaining proper draft and clearances. A correctly fitted transition is essential for safe, code-compliant venting of flue gases out of the home.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Flue \/ vent transition bottom panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Coated\/galvanized steel for high-temperature service\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Routes combustion byproducts from collector box to vent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part #:\u003c\/strong\u003e 0128F00006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e Goodman ACEC800603AXAA and select Goodman\/Amana gas furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOEM vs. Generic:\u003c\/strong\u003e The genuine OEM 0128F00006 matches the exact stamping, hole pattern, and clearances of this furnace cabinet, ensuring a leak-free seal at the collector and vent connection. Universal sheet-metal substitutes rarely line up correctly and can leave gaps that allow flue-gas leakage. For a venting safety part, OEM fitment is recommended.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstallation difficulty:\u003c\/strong\u003e Moderate (★★★☆☆). Power down the furnace, remove the existing transition, transfer or replace gasketing, and secure with the factory screws. Confirm a tight, sealed joint and verify proper draft after restart. Improper venting is a carbon-monoxide hazard — if unsure, consult a qualified technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057161290099,"sku":"GOODMAN-7","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-7.jpg?v=1783394016"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acec800603axab-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACEC800603AXAB — 0128F00006","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is a genuine OEM flue\/vent component for the Goodman\/Amana \u003cstrong\u003eACEC800603AXAB\u003c\/strong\u003e furnace. This sheet-metal transition channels hot combustion gases from the heat exchanger collector into the draft hood and vent connector, maintaining proper draft and a sealed flue path. A corroded or ill-fitting transition can leak flue gases and disrupt venting — replacing it with the correct OEM part restores a safe, factory-tight connection.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Flue\/vent chimney transition (bottom section)\u003c\/li\u003e\n\u003cli\u003eFunction: Routes flue gases from collector to vent\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 0128F00006\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman \/ Amana (interchangeable)\u003c\/li\u003e\n\u003cli\u003eFits: ACEC800603AXAB and related furnace models\u003c\/li\u003e\n\u003cli\u003eMaterial: Coated\/galvanized steel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003eOEM\u003c\/strong\u003e transition is stamped to the exact dimensions and gasket pattern of your furnace's vent opening. Generic or fabricated substitutes rarely seal correctly, risking flue-gas leakage. For any venting component, an exact OEM fit is the safe choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty: Moderate\u003c\/h3\u003e\u003cp\u003eInvolves removing fasteners and the existing transition, then resealing the new part with the proper gasket or high-temp sealant. Because it affects combustion venting, a draft and spillage test should follow installation. Disconnect power and gas before servicing; when in doubt, use a licensed technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057161617779,"sku":"GOODMAN-0128F00006","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-0128F00006_8ddcddd9-017e-41a0-b808-bfdb874bcf03.jpg?v=1783394018"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acec800804bxaa-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACEC800804BXAA — 0128F00006","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is the genuine OEM flue vent component for the \u003cstrong\u003eACEC800804BXAA\u003c\/strong\u003e gas furnace and compatible Goodman\/Amana 80% AFUE models. This transition piece forms the lower connection between the furnace vent outlet and the chimney\/vent connector, channeling flue gases safely out of the heat exchanger area. A correctly sealed transition is essential for proper draft and safe combustion-byproduct evacuation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0128F00006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Chimney \/ flue transition (bottom)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits Model:\u003c\/strong\u003e ACEC800804BXAA (80K BTU, 80% AFUE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Galvanized sheet metal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Flue gas routing \u0026amp; vent connector seat\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis is a \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e part, stamped and formed to the exact dimensions of the factory vent opening. Generic or universal transitions often require trimming and rarely seal flush, risking flue gas leakage. For a venting component, exact OEM fitment is the safest choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — requires shutting off gas and power, removing the existing vent connection, and properly seating\/sealing the new transition. We recommend a qualified HVAC technician verify draft after install.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057162338675,"sku":"GOODMAN-45","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-45.jpg?v=1783394023"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acec800804bxab-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACEC800804BXAB — 0128F00006","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is the genuine OEM venting component used on the \u003cstrong\u003eACEC800804BXAB\u003c\/strong\u003e and compatible Goodman\/Amana gas furnace assemblies. It forms the lower transition between the heat exchanger collector box and the flue outlet, maintaining the correct draft path and a sealed, code-compliant vent connection. A worn, corroded, or warped transition can cause draft problems, nuisance pressure-switch lockouts, and flue-gas leakage — replacing it with the exact factory part restores proper venting.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0128F00006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent:\u003c\/strong\u003e Chimney \/ flue transition (bottom)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Model:\u003c\/strong\u003e ACEC800804BXAB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman (also fits select Amana units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Coated steel venting stamping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Connects collector box to flue outlet\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOEM vs. Generic:\u003c\/strong\u003e This is the genuine Goodman component, stamped and coated to the original tolerances so it drops into place without modification. Generic or fabricated transitions often require trimming and can compromise the vent seal — the OEM part guarantees correct geometry and a tight, lasting fit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstall Difficulty:\u003c\/strong\u003e Moderate — requires removing the venting connection and is best handled by an HVAC professional. Always shut off gas and power before servicing venting components.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057162830195,"sku":"GOODMAN-55","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-55.jpg?v=1783394024"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acec800805cxaa-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACEC800805CXAA — 0128F00006","description":"\u003cp\u003eThe genuine OEM Goodman \u003cstrong\u003e0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is a factory-engineered flue and vent component designed for the Goodman \u003cstrong\u003eACEC800805CXAA\u003c\/strong\u003e furnace. This transition piece directs combustion byproducts from the heat exchanger collector toward the vent connector, maintaining the correct draft path and a safe, sealed flue route. Using the exact OEM part preserves the original venting geometry and gasket fit that aftermarket substitutes often miss.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 0128F00006\u003c\/li\u003e\n\u003cli\u003eCategory: Flue \/ Vent Transition\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACEC800805CXAA\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003eFunction: Bottom chimney\/flue transition\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe genuine Goodman part is stamped to the original dimensions and clearances, so it seats correctly against the heat exchanger and vent without gaps. Generic alternatives may require trimming or extra sealing and risk improper draft. For a safety-critical venting part, OEM is the recommended choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate.\u003c\/strong\u003e Requires powering down the furnace, removing the vent connector, and resealing the transition. Recommended for experienced DIYers or an HVAC technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057163190643,"sku":"GOODMAN-65","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-65.jpg?v=1783394026"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acec801005cxaa-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACEC801005CXAA — 0128F00006","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is a genuine OEM flue\/vent component that adapts the furnace heat exchanger outlet to the chimney or vent connector on the \u003cstrong\u003eACEC801005CXAA\u003c\/strong\u003e and other compatible Goodman\/Amana gas furnaces. This sheet-metal transition channels hot combustion gases safely from the furnace into the venting system, maintaining proper draft and a sealed exhaust path.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFunction: Chimney \/ flue transition (bottom section)\u003c\/li\u003e\n\u003cli\u003eOEM part number: 0128F00006\u003c\/li\u003e\n\u003cli\u003eFits: Goodman ACEC801005CXAA and compatible models\u003c\/li\u003e\n\u003cli\u003eMaterial: Coated\/galvanized steel for high-temp exhaust service\u003c\/li\u003e\n\u003cli\u003eProfile: Factory-stamped for an exact venting alignment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe OEM transition is stamped to match the furnace cabinet and vent connector dimensions exactly, so it seals without gaps or field fabrication. Generic sheet-metal substitutes usually require cutting, crimping, and extra sealant, and a poor fit risks flue-gas leakage. The OEM 0128F00006 drops in for a clean, code-compliant exhaust path.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy to Moderate.\u003c\/strong\u003e The transition is typically secured with sheet-metal screws once the old piece is removed. Power and gas should be off during service, and all flue joints must be sealed and draft-tested afterward. Because it carries combustion gases, verify proper draft before returning the unit to service.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057163616627,"sku":"GOODMAN-81","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-81.jpg?v=1783394029"},{"product_id":"oem-goodman-condensate-drain-trap-for-acec960603bnaa-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACEC960603BNAA — 0161F00046","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0161F00046 Condensate Drain Trap\u003c\/strong\u003e is a genuine OEM replacement for the \u003cstrong\u003eACEC960603BNAA\u003c\/strong\u003e high-efficiency (96%) furnace and compatible Goodman\/Amana condensing models. The drain trap carries acidic condensate away from the secondary heat exchanger and inducer while maintaining the pressure seal the system needs to operate. A cracked, clogged, or brittle trap causes water leaks, pressure-switch faults, and ignition lockouts.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 0161F00046\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman\u003c\/li\u003e\n\u003cli\u003eFits Model: ACEC960603BNAA\u003c\/li\u003e\n\u003cli\u003eApplication: High-efficiency \/ condensing gas furnaces\u003c\/li\u003e\n\u003cli\u003eFunction: Condensate evacuation with pressure seal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM\u003c\/strong\u003e trap matches the exact port spacing, fitting sizes, and float configuration of the furnace, so it seals correctly and won't trigger phantom pressure-switch errors. Generic universal traps frequently require adapters and risk leaks at mismatched connections. For condensing furnaces, an exact-fit OEM trap is strongly recommended.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — requires disconnecting condensate hoses and reseating fittings without leaks. Shut off power and have a towel ready for residual water. Budget 30–45 minutes; verify all hose clamps are tight and test for proper drainage before closing the cabinet.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057165287795,"sku":"GOODMAN-123","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785039995251.jpg?v=1785039996"},{"product_id":"oem-goodman-condensate-drain-trap-for-acec960803bnab-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACEC960803BNAB — 0161F00046","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0161F00046 Condensate Drain Trap\u003c\/strong\u003e is a genuine OEM replacement for the \u003cstrong\u003eACEC960803BNAB\u003c\/strong\u003e and compatible Goodman\/Amana high-efficiency furnaces. The trap collects and routes condensate produced by the secondary heat exchanger while maintaining a water seal that blocks combustion flue gases from escaping into the drain line and living space.\u003c\/p\u003e\u003cp\u003eA cracked, clogged, or missing drain trap is a leading cause of water leaks, condensate overflow, pressure-switch lockouts, and 'flame proving' faults. Installing the correct OEM trap restores proper drainage and safe pressure-switch operation.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0161F00046\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Maintains water seal and drains heat-exchanger condensate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e Goodman ACEC960803BNAB and related condensing furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman OEM\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOEM vs. Generic:\u003c\/strong\u003e The OEM 0161F00046 is molded to match the exact port spacing, hose-barb sizing, and float\/seal geometry of your furnace. Generic traps often require adapters and may not seat against the original mounting points, increasing the risk of leaks. OEM ensures a leak-free, drop-in fit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstall Difficulty:\u003c\/strong\u003e Easy to Moderate (2\/5). Requires disconnecting condensate hoses and clearing any existing blockage; about 20–30 minutes. Shut off power and gas before servicing.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057166532979,"sku":"GOODMAN-156","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785040009619.jpg?v=1785040010"},{"product_id":"oem-goodman-condensate-drain-trap-for-acec961005cnaa-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACEC961005CNAA — 0161F00046","description":"\u003ch2\u003eGoodman 0161F00046 Condensate Drain Trap\u003c\/h2\u003e\u003cp\u003eThe Goodman 0161F00046 is a genuine OEM condensate drain trap for the \u003cstrong\u003eACEC961005CNAA\u003c\/strong\u003e and compatible Goodman\/Amana high-efficiency condensing furnaces. The trap collects acidic condensate from the secondary heat exchanger and routes it to the drain while maintaining a water seal that blocks flue gases from escaping into the cabinet — essential for safe, efficient operation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Integrated condensate trap assembly\u003c\/li\u003e\n\u003cli\u003eFunction: Drains condensate, maintains flue-gas water seal\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded corrosion-resistant polymer\u003c\/li\u003e\n\u003cli\u003ePorts: Inlet, drain, and vent connections\u003c\/li\u003e\n\u003cli\u003eFits: Goodman ACEC961005CNAA and compatible models\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM\u003c\/strong\u003e 0161F00046 is molded to the precise port spacing and seal geometry of your furnace, preventing leaks and improper draining. Generic traps may not align with factory tubing runs, risking water spillage and pressure-switch faults. OEM is the safe choice for condensate handling.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate.\u003c\/strong\u003e Requires disconnecting and reconnecting condensate tubing, clearing any blockage, and verifying the water seal. Allow 20–30 minutes. Have towels ready for residual condensate.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057166893427,"sku":"GOODMAN-167","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785040017439.jpg?v=1785040018"},{"product_id":"oem-goodman-condensate-drain-trap-for-acec961005cnab-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACEC961005CNAB — 0161F00046","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0161F00046 Condensate Drain Trap\u003c\/strong\u003e is a genuine OEM component for the \u003cstrong\u003eACEC961005CNAB\u003c\/strong\u003e and compatible high-efficiency Goodman\/Amana units. The trap channels acidic condensate away from the heat exchanger and secondary coil while maintaining a water seal that blocks flue gases from escaping into the cabinet — essential for safe, reliable operation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFunction: Condensate collection and drainage trap\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded condensate-resistant polymer\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 0161F00046\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACEC961005CNAB\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman\u003c\/li\u003e\n\u003cli\u003eIncludes: Trap body with inlet\/outlet ports\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine OEM\u003c\/strong\u003e trap is molded to fit the factory drain ports and condensate routing precisely. Generic traps may not seal correctly or align with existing tubing, leading to leaks, blocked drainage, and water damage. OEM ensures a leak-free, code-compliant fit.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (3\/5)\u003c\/strong\u003e — Requires disconnecting condensate tubing, removing the old trap, and re-sealing connections. Prime the new trap with water before startup. Plan for 20–30 minutes; a licensed technician is recommended if drain routing is unclear.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057169842547,"sku":"GOODMAN-177","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785040024506.jpg?v=1785040025"},{"product_id":"oem-goodman-10-x-8-blower-wheel-for-wgph4549amab-d6723303s-1","title":"OEM Goodman 10 x 8 Blower Wheel for WGPH4549AMAB — D6723303S","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman D6723303S Blower Wheel\u003c\/strong\u003e is a genuine OEM 10 in. x 8 in. forward-curved (squirrel cage) blower wheel built for the \u003cstrong\u003eWGPH4549AMAB\u003c\/strong\u003e packaged gas\/electric unit. The blower wheel is the heart of indoor airflow — it draws return air across the heat exchanger and coil and pushes conditioned air through the duct system. A cracked hub, bent blades, or accumulated debris causes vibration, noise, and reduced CFM, so a factory-balanced replacement restores rated airflow and protects the motor bearings.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Forward-curved blower wheel (squirrel cage)\u003c\/li\u003e\n\u003cli\u003eDimensions: 10 in. diameter x 8 in. width\u003c\/li\u003e\n\u003cli\u003eOEM part number: D6723303S\u003c\/li\u003e\n\u003cli\u003eCompatible model: WGPH4549AMAB\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003eConstruction: Galvanized steel, factory dynamically balanced\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe genuine Goodman wheel is factory-balanced and dimensionally matched to the housing and motor shaft, so it spins true with minimal vibration. Generic wheels may use a different bore, set-screw location, or blade pitch, which can throw off balance and airflow and shorten motor life. For a rotating component running thousands of hours a season, the OEM wheel is the dependable choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (3\/5).\u003c\/strong\u003e Disconnect power, remove the blower assembly, loosen the set screw, slide the old wheel off the motor shaft, and reinstall the new wheel at the same depth and orientation. Verify the set screw lands on the shaft flat and that the wheel clears the housing before restoring power.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057217290611,"sku":"GOODMAN-1061","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-wheel-D6723303S-1-1785044765207.jpg?v=1785044766"},{"product_id":"oem-goodman-chimney-transition-bottom-for-aces800403axaa-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACES800403AXAA — 0128F00006","description":"\u003ch2\u003eGoodman 0128F00006 Chimney Transition Bottom\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e0128F00006\u003c\/strong\u003e chimney transition bottom is the sheet-metal flue-vent component that channels combustion byproducts from the furnace heat exchanger out toward the vent connector on the Goodman\/Amana \u003cstrong\u003eACES800403AXAA\u003c\/strong\u003e and compatible 80% AFUE gas furnaces. A correctly seated transition maintains proper draft and a sealed flue path, preventing dangerous flue-gas spillage into the equipment cabinet.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFunction: Flue \/ vent transition (bottom section)\u003c\/li\u003e\n\u003cli\u003eFits: Goodman \u0026amp; Amana ACES800403AXAA and compatible 80% furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Coated\/galvanized furnace-grade steel\u003c\/li\u003e\n\u003cli\u003ePart type: Venting component\u003c\/li\u003e\n\u003cli\u003ePosition: Bottom transition at heat-exchanger collector box\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine OEM Goodman\u003c\/strong\u003e transition is stamped to the exact contour and dimensions of your furnace's collector box and vent outlet. Generic flat stock or universal fittings rarely seal correctly against the factory gasketing, which can create draft and condensation problems. The OEM part bolts in with no fabrication required.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — Involves removing the existing vent connection, swapping the transition, and re-sealing the flue path. Because it is part of the combustion venting system, a licensed HVAC technician should verify draft and check for spillage after installation. Plan 30–45 minutes.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057420058995,"sku":"GOODMAN-2186","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-2186.jpg?v=1783394034"},{"product_id":"oem-goodman-chimney-transition-bottom-aces801005cxaa-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom ACES801005CXAA — 0128F00006","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is a genuine OEM flue\/vent component for \u003cstrong\u003eACES801005CXAA\u003c\/strong\u003e gas furnaces. This transition piece directs combustion gases from the heat exchanger collector box into the vent connector, forming a sealed pathway to the chimney. A corroded or warped transition can leak flue products into the equipment space, so a properly fitted OEM part is critical for safe venting.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Chimney \/ vent transition (bottom)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Routes flue gases from collector box to vent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0128F00006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Goodman\/Amana ACES801005CXAA furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Corrosion-resistant flue-grade metal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Genuine Goodman OEM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0128F00006\u003c\/strong\u003e is formed to mate exactly with the ACES801005CXAA collector box and vent. Generic or fabricated transitions risk poor seals and improper draft. For any flue-gas-carrying component, OEM fit is the safe choice.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstall Difficulty:\u003c\/strong\u003e Moderate (3\/5). Requires removing the existing transition and resealing the flue connections. Shut off gas and power, and perform a combustion\/draft check after installation. Professional installation recommended.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057421992307,"sku":"GOODMAN-2239","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-2239.jpg?v=1783393939"},{"product_id":"oem-goodman-condensate-drain-trap-for-aces961005cnaa-furnace-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACES961005CNAA Furnace — 0161F00046","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0161F00046 Condensate Drain Trap\u003c\/strong\u003e is a genuine OEM replacement component engineered for the \u003cstrong\u003eGoodman ACES961005CNAA\u003c\/strong\u003e high-efficiency gas furnace. The drain trap channels acidic condensate away from the heat exchanger and inducer assembly, preventing standing water, blocked drains, and pressure-switch lockout faults that trigger nuisance no-heat calls.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGoodman OEM part number: 0161F00046\u003c\/li\u003e\n\u003cli\u003eComponent type: Condensate drain trap\u003c\/li\u003e\n\u003cli\u003eEquipment type: Gas furnace\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACES961005CNAA\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded high-temperature polymer\u003c\/li\u003e\n\u003cli\u003eIncludes integrated barbed drain ports\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis is the authentic Goodman-specified trap with the exact port geometry and trap depth required for proper condensate flow. Universal aftermarket traps often require adapter fittings and can leak or restrict drainage; the OEM unit drops in with no modification and preserves your equipment warranty.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2\/5)\u003c\/strong\u003e — Disconnect the drain tubing, remove the failed trap, prime the new trap with water, and reconnect. Most installs take under 20 minutes with basic hand tools. Always shut off power at the furnace disconnect before servicing.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057430839667,"sku":"GOODMAN-2285","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785040052707.jpg?v=1785040053"},{"product_id":"oem-goodman-condensate-drain-trap-for-aces961205dnaa-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACES961205DNAA — 0161F00046","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0161F00046 Condensate Drain Trap\u003c\/strong\u003e is a genuine OEM replacement for the \u003cstrong\u003eACES961205DNAA\u003c\/strong\u003e 96% AFUE furnace and compatible Goodman\/Amana high-efficiency models. The trap collects acidic condensate from the secondary heat exchanger and inducer while maintaining a water seal that prevents flue gases from escaping into the drain line.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eApplication: High-efficiency (condensing) gas furnaces\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 0161F00046\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACES961205DNAA\u003c\/li\u003e\n\u003cli\u003eFunction: Maintains water seal, drains secondary condensate\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eA \u003cstrong\u003egenuine OEM trap\u003c\/strong\u003e matches the exact port spacing and hose-barb diameters of your furnace, so the factory tubing connects without adapters or leaks. Generic traps can shift the inlet\/outlet geometry and stress the corrugated hoses. Choose OEM for a clean, leak-free seal.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (2\/5).\u003c\/strong\u003e Power down, slip off the condensate hoses, remove the old trap, prime the new trap with water to establish the seal, and reconnect. Plan for 15 minutes; have a rag ready for residual condensate.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057446371699,"sku":"GOODMAN-2297","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785040059347.jpg?v=1785040060"},{"product_id":"oem-goodman-condensate-drain-trap-for-acsh960453bxaa-furnace-20171702","title":"OEM Goodman Condensate Drain Trap for ACSH960453BXAA Furnace — 20171701","description":"\u003ch2\u003eGoodman 20171701 Condensate Drain Trap\u003c\/h2\u003e\u003cp\u003eThe Goodman 20171701 is a genuine OEM condensate drain trap designed as an exact-fit replacement for the Goodman \u003cstrong\u003eACSH960453BXAA\u003c\/strong\u003e high-efficiency condensing furnace and compatible 96% AFUE models. In a condensing furnace, the secondary heat exchanger produces acidic condensate that must drain away cleanly; this trap maintains the proper water seal that prevents flue gases from escaping into the cabinet while allowing condensate to flow to the drain.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20171701\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003eApplication: 96% AFUE condensing gas furnace condensate management\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACSH960453BXAA and related Goodman furnaces\u003c\/li\u003e\n\u003cli\u003eFunction: Maintains water seal and routes acidic condensate to drain line\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e trap is molded to the exact port spacing, inlet\/outlet diameters, and water-column height your furnace requires. Generic traps may leak, fail to hold a seal, or fit poorly against the heat-exchanger condensate ports — causing pressure-switch faults and furnace lockouts. The OEM part drops in without modification.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy to Moderate\u003c\/strong\u003e — usually 20–30 minutes. Disconnect the inlet and outlet drain hoses, unclip or unscrew the old trap, install the new trap, and reconnect the hoses. Prime the trap with water before restarting so the seal is established. Always shut off power before servicing. A clogged or cracked trap is a common cause of furnace short-cycling, so replacing it often resolves pressure-switch error codes.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057446863219,"sku":"GOODMAN-2301","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-20171701-1-1785037374823.jpg?v=1785037375"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acsh960453bxaa-20201803","title":"OEM Goodman Condensate Drain Hose Tube for ACSH960453BXAA — 20201802","description":"\u003ch2\u003eGoodman 20201802 Condensate Drain Hose Tube\u003c\/h2\u003e\u003cp\u003eThe Goodman 20201802 is a genuine OEM condensate drain hose tube cut and formed for the Goodman \u003cstrong\u003eACSH960453BXAA\u003c\/strong\u003e condensing furnace and compatible 96% AFUE platforms. This flexible tubing carries condensate between the secondary heat exchanger, the drain trap, and the inducer\/pressure-switch connections, keeping the furnace's condensate path sealed and properly routed.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Flexible condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20201802\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003eApplication: 96% AFUE condensing gas furnace condensate routing\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACSH960453BXAA and related Goodman furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Furnace-grade flexible tubing, condensate-rated\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e hose is pre-cut to the correct length and inner diameter for your furnace's drain layout. Generic tubing purchased by the foot may be the wrong bore, kink at the factory bends, or slip off the barbed fittings — leading to condensate leaks and pressure-switch faults. The OEM tube seats securely on the original fittings.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — a 5–10 minute swap. Pull the old hose off its barbed fittings, slide the new hose into place, and secure with the original clamps if equipped. Shut off power before servicing. Inspect for kinks and confirm a tight fit so the condensate path stays sealed.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057446895987,"sku":"GOODMAN-2302","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917811692.jpg?v=1784917812"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acsh960453bxaa-20201902","title":"OEM Goodman Condensate Drain Hose Tube for ACSH960453BXAA — 20201901","description":"\u003ch2\u003eGoodman 20201901 Condensate Drain Hose Tube\u003c\/h2\u003e\u003cp\u003eThe Goodman 20201901 is a genuine OEM condensate drain hose tube formed specifically for the Goodman \u003cstrong\u003eACSH960453BXAA\u003c\/strong\u003e condensing furnace and compatible 96% AFUE models. It routes acidic condensate from the secondary heat exchanger through the drain trap, maintaining a sealed, correctly shaped path that keeps the pressure-switch circuit stable and prevents cabinet leaks.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Flexible condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20201901\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003eApplication: 96% AFUE condensing gas furnace condensate routing\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACSH960453BXAA and related Goodman furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Furnace-grade flexible tubing, condensate-rated\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e hose is molded to the exact length, bends, and bore of the original part. Generic bulk tubing often kinks at the molded elbows, uses the wrong inner diameter, or slips off the barbed fittings — causing condensate leaks and nuisance pressure-switch lockouts. The OEM tube installs without modification and holds its shape.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — typically a 5–10 minute job. Remove the old hose from its barbed fittings, route the new hose along the same path, and secure with the original clamps. Always shut off power before servicing. Verify there are no kinks and that both ends seat fully so the condensate drains freely.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057446928755,"sku":"GOODMAN-2303","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201901-1-1784915176245.jpg?v=1784915177"},{"product_id":"oem-goodman-23-in-condensate-drain-hose-tube-for-acsh960453bxaa-20201903","title":"OEM Goodman 23 in. Condensate Drain Hose Tube for ACSH960453BXAA — 20201902","description":"\u003ch2\u003eGoodman 20201902 23-Inch Condensate Drain Hose Tube\u003c\/h2\u003e\u003cp\u003eThe Goodman 20201902 is a genuine OEM 23-inch condensate drain hose tube cut to length for the Goodman \u003cstrong\u003eACSH960453BXAA\u003c\/strong\u003e condensing furnace and compatible 96% AFUE platforms. This longer run of flexible tubing carries condensate between the heat exchanger, drain trap, and discharge connection, keeping the furnace's condensate path sealed and correctly routed across the cabinet.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Flexible condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eLength: 23 inches (pre-cut)\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20201902\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003eApplication: 96% AFUE condensing gas furnace condensate routing\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACSH960453BXAA and related Goodman furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e hose arrives pre-cut to the correct 23-inch length with the right inner diameter for your furnace. Generic tubing sold by the foot may be the wrong bore, kink at the bends, or fit loosely on the barbed fittings — risking condensate leaks and pressure-switch faults. The OEM tube seats securely and routes exactly as the factory intended.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — a 5–10 minute swap. Detach the old hose from its barbed fittings, route the new 23-inch hose along the original path, and secure with the existing clamps if equipped. Shut off power before servicing. Check for kinks and confirm both ends are fully seated so condensate drains freely.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057446961523,"sku":"GOODMAN-2304","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201902-1-1784912585814.jpg?v=1784912587"},{"product_id":"oem-goodman-condensate-drain-angle-for-acsh960453bxaa-20214204","title":"OEM Goodman Condensate Drain Angle for ACSH960453BXAA — 20214203","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20214203 condensate drain angle\u003c\/strong\u003e is a genuine OEM component engineered for the \u003cstrong\u003eGoodman ACSH960453BXAA\u003c\/strong\u003e high-efficiency gas furnace and other compatible 96% AFUE models. This drain fitting routes condensate away from the heat exchanger and inducer assembly, helping prevent water pooling, corrosion, and nuisance pressure-switch lockouts that occur when condensate cannot drain freely.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20214203\u003c\/li\u003e\n\u003cli\u003ePart Type: Condensate drain angle \/ fitting\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (Genuine OEM)\u003c\/li\u003e\n\u003cli\u003eEquipment: Gas Furnace\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACSH960453BXAA\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded furnace-grade polymer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis is a \u003cstrong\u003egenuine Goodman OEM part\u003c\/strong\u003e, molded to the exact angle and port dimensions the ACSH960453BXAA drain system requires. Aftermarket fittings often differ slightly in barb size or angle, which can cause slow leaks or improper drainage. Choosing OEM ensures a leak-free, drop-in fit and preserves any remaining factory warranty coverage on your furnace.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1 of 5).\u003c\/strong\u003e Replacement is a basic, no-tools-or-simple-hand-tools job: power down the furnace, disconnect the existing drain tubing, swap the angle, and reconnect. Always confirm tubing is fully seated and clamped. If you are unsure about your furnace's drain routing, consult a licensed HVAC technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057446994291,"sku":"GOODMAN-2305","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-angle-20214203-1-1784920029443.jpg?v=1784920030"},{"product_id":"oem-goodman-drain-hose-tube-for-acsh960703bxaa-20201803","title":"OEM Goodman Drain Hose Tube for ACSH960703BXAA — 20201802","description":"\u003ch2\u003eGoodman 20201802 Condensate Drain Hose Tube\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e20201802\u003c\/strong\u003e is a genuine OEM condensate drain hose tube engineered for the \u003cstrong\u003eACSH960703BXAA\u003c\/strong\u003e high-efficiency gas furnace and other compatible Goodman\/Amana 96% AFUE models. During normal operation a condensing furnace produces water vapor that must be routed safely to the drain. This molded hose carries that condensate from the secondary heat exchanger and collector box to the drain trap, preventing leaks, overflow, and water damage around your equipment.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20201802\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACSH960703BXAA (Goodman 96% gas furnace)\u003c\/li\u003e\n\u003cli\u003eEquipment Type: High-efficiency condensing furnace\u003c\/li\u003e\n\u003cli\u003eFunction: Routes condensate from collector box to drain trap\u003c\/li\u003e\n\u003cli\u003eMaterial: Chemical-resistant molded tubing\u003c\/li\u003e\n\u003cli\u003eFit: Direct OEM replacement — no modification required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eChoosing the genuine Goodman OEM 20201802 guarantees an exact dimensional match to the factory routing path and connection ports. Aftermarket or universal hoses often require trimming, adapters, or zip-tie workarounds that can kink, leak, or detach over time. The OEM part installs in seconds and maintains your furnace's original drainage design and warranty integrity.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eRating: Easy (1\/5)\u003c\/strong\u003e — A basic DIY repair requiring no special tools. Power down the furnace, slide the failed hose off its barbed fittings, and press the replacement into place. Inspect the drain trap for debris while you are in there. Most homeowners complete this in under 10 minutes.\u003c\/p\u003e\u003cp\u003eBacked by genuine Goodman quality. Order today for fast shipping.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057447158131,"sku":"GOODMAN-2310","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917819404.jpg?v=1784917821"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acsh960704cxaa-20201803","title":"OEM Goodman Condensate Drain Hose Tube for ACSH960704CXAA — 20201802","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20201802 Condensate Drain Hose Tube\u003c\/strong\u003e is a genuine OEM drain line for the Goodman \u003cstrong\u003eACSH960704CXAA\u003c\/strong\u003e 96% AFUE condensing gas furnace and related Goodman\/Amana models. This flexible tube routes acidic condensate between the secondary heat exchanger, drain trap, and inducer assembly. Replacing a cracked, brittle, or clogged hose restores proper drainage and clears nuisance pressure-switch lockouts.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eOEM part number: 20201802\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman \/ Amana\u003c\/li\u003e\n\u003cli\u003eEquipment: 96% AFUE condensing gas furnace\u003c\/li\u003e\n\u003cli\u003eFits model: ACSH960704CXAA and related Goodman furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Condensate-rated flexible tubing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e hose is pre-cut and formed to the exact length and bend radius for your furnace's drain routing. Generic tubing often has the wrong inside diameter or kinks at the bends, causing slow drainage, water backup, and pressure-switch faults. OEM ensures a leak-free, correctly routed fit.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy.\u003c\/strong\u003e Power down the furnace, slip the old hose off its barbed fittings, and press the new tube onto the same connections. No tools are typically required and the swap takes only a few minutes. Verify there are no kinks and that condensate flows freely before restoring power.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDisconnect power before servicing. Confirm compatibility using your furnace's full model and serial number.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057447780723,"sku":"GOODMAN-20201802","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917828370.jpg?v=1784917829"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acsh960704cxaa-20201902","title":"OEM Goodman Condensate Drain Hose Tube for ACSH960704CXAA — 20201901","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20201901 Condensate Drain Hose Tube\u003c\/strong\u003e is a genuine OEM drain line built for the Goodman \u003cstrong\u003eACSH960704CXAA\u003c\/strong\u003e 96% AFUE condensing gas furnace and related Goodman\/Amana models. This formed tube carries acidic condensate between the secondary heat exchanger, drain trap, and inducer, keeping the high-efficiency drainage system sealed and flowing. Swapping a hardened or clogged hose restores drainage and prevents pressure-switch lockouts and water leaks inside the cabinet.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eOEM part number: 20201901\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman \/ Amana\u003c\/li\u003e\n\u003cli\u003eEquipment: 96% AFUE condensing gas furnace\u003c\/li\u003e\n\u003cli\u003eFits model: ACSH960704CXAA and related Goodman furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Condensate-rated flexible tubing, pre-formed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e hose matches the factory length, diameter, and pre-shaped bends for your furnace's drain path. Generic replacements often kink or use the wrong bore, causing backups and inducer faults. OEM guarantees correct routing and a reliable, leak-free seal.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy.\u003c\/strong\u003e Power down the furnace, remove the old hose from its barbed fittings, and press the new tube onto the same ports. The job usually needs no tools and takes only a few minutes. Confirm the line is kink-free and draining before restoring power.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDisconnect power before servicing. Confirm compatibility using your furnace's full model and serial number.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057447813491,"sku":"GOODMAN-20201901","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201901-1-1784915191255.jpg?v=1784915192"},{"product_id":"oem-goodman-23-in-condensate-drain-hose-for-acsh960704cxaa-20201903","title":"OEM Goodman 23 in. Condensate Drain Hose for ACSH960704CXAA — 20201902","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20201902 23-inch Condensate Drain Hose Tube\u003c\/strong\u003e is a genuine OEM drain line cut to length for the Goodman \u003cstrong\u003eACSH960704CXAA\u003c\/strong\u003e 96% AFUE condensing gas furnace and related Goodman\/Amana models. This 23\" pre-cut tube routes acidic condensate between the secondary heat exchanger, drain trap, and inducer, keeping the high-efficiency drainage path sealed and flowing. Replacing a cracked, brittle, or clogged hose restores proper drainage and clears nuisance pressure-switch lockouts.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart type: Condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eOEM part number: 20201902\u003c\/li\u003e\n\u003cli\u003eLength: 23 inches (pre-cut)\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman \/ Amana\u003c\/li\u003e\n\u003cli\u003eEquipment: 96% AFUE condensing gas furnace\u003c\/li\u003e\n\u003cli\u003eFits model: ACSH960704CXAA and related Goodman furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e hose arrives at the correct 23-inch length with the right inside diameter and bend memory for your furnace's drain routing. Generic bulk tubing has to be cut on site and often kinks or mismatches the bore, causing backups and inducer faults. OEM removes the guesswork and ensures a leak-free fit.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy.\u003c\/strong\u003e Power down the furnace, pull the old hose off its barbed fittings, and press the new 23\" tube onto the same connections. No tools are typically required and the swap takes only a few minutes. Verify the line is kink-free and draining before restoring power.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDisconnect power before servicing. Confirm compatibility using your furnace's full model and serial number.\u003c\/em\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057447846259,"sku":"GOODMAN-20201902","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201902-1-1784912601202.jpg?v=1784912602"},{"product_id":"oem-goodman-condensate-drain-trap-for-acsh960905dxaa-20171702","title":"OEM Goodman Condensate Drain Trap for ACSH960905DXAA — 20171701","description":"\u003ch2\u003eGoodman 20171701 Condensate Drain Trap\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e20171701\u003c\/strong\u003e condensate drain trap collects and drains the acidic condensate produced by the secondary heat exchanger of the \u003cstrong\u003eACSH960905DXAA\u003c\/strong\u003e 96% AFUE furnace. It maintains a water seal that blocks flue gases from escaping the drain line while allowing condensate to flow away. A cracked or clogged trap causes water leaks, pressure-switch faults, and nuisance lockouts.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eFunction: Drains secondary heat-exchanger condensate, maintains flue-gas seal\u003c\/li\u003e\n\u003cli\u003eMaterial: Corrosion-resistant molded plastic\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20171701\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (fits Amana equivalents)\u003c\/li\u003e\n\u003cli\u003eFits: ACSH960905DXAA and related Goodman 96% furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eOEM Goodman\u003c\/strong\u003e traps match the exact port locations, internal baffles, and hose-barb sizes of the factory unit, so they seat correctly and seal the pressure-switch tubing. Generic universal traps often require adapters and can trigger pressure-switch errors. OEM ensures a clean, leak-free fit.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — involves disconnecting condensate and pressure-switch hoses and clearing the drain line. Power down the furnace, label hoses before removal, and prime the new trap with water to establish the seal before restart.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057456234867,"sku":"GOODMAN-2344","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-20171701-1-1785037395902.jpg?v=1785037396"},{"product_id":"oem-goodman-drain-hose-tube-for-acsh960905dxaa-20201803","title":"OEM Goodman Drain Hose Tube for ACSH960905DXAA — 20201802","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20201802 Drain Hose Tube\u003c\/strong\u003e is a genuine OEM condensate drainage component engineered for the Goodman \u003cstrong\u003eACSH960905DXAA\u003c\/strong\u003e gas furnace and compatible models. It routes condensate water away from the heat exchanger and inducer assembly, helping prevent overflow, corrosion, and water damage inside the furnace cabinet. Because it is the factory-specified part, it matches the original port diameters and routing path exactly — no trimming, adapters, or guesswork.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Type: Condensate drain hose tube\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20201802\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACSH960905DXAA (Goodman gas furnace)\u003c\/li\u003e\n\u003cli\u003eEquipment: Furnace condensate \/ drainage system\u003c\/li\u003e\n\u003cli\u003eMaterial: Heat- and moisture-resistant tubing\u003c\/li\u003e\n\u003cli\u003eFitment: Direct OEM replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eGeneric aftermarket hoses are often cut to approximate lengths and may not seat correctly on the furnace's molded drain ports, leading to slow leaks and nuisance lockouts. This \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e tube guarantees the correct bore, wall thickness, and length so connections stay tight over the life of the furnace.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Disconnect power, remove the old hose from its barbed fittings, and slide the new tube into place. Typically a 5–10 minute job requiring no special tools. Always shut off power and gas before servicing.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057456267635,"sku":"GOODMAN-2345","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917844458.jpg?v=1784917845"},{"product_id":"oem-goodman-drain-hose-tube-for-acsh960905dxaa-20201902","title":"OEM Goodman Drain Hose Tube for ACSH960905DXAA — 20201901","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20201901 Drain Hose Tube\u003c\/strong\u003e is a factory OEM condensate drain line built for the Goodman \u003cstrong\u003eACSH960905DXAA\u003c\/strong\u003e high-efficiency furnace and related models. It carries acidic condensate from the secondary heat exchanger and collector box to the drain trap, protecting internal components from standing water and rust. As the manufacturer-specified part, it delivers exact length and fitment for a clean, reliable installation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Type: Condensate drain hose tube\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20201901\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACSH960905DXAA (Goodman gas furnace)\u003c\/li\u003e\n\u003cli\u003eEquipment: Furnace condensate \/ drainage system\u003c\/li\u003e\n\u003cli\u003eMaterial: Chemical- and heat-resistant tubing\u003c\/li\u003e\n\u003cli\u003eFitment: Direct OEM replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eUniversal hose kits force you to measure and cut, and the wrong inner diameter can pop off the collector-box nipple under thermal cycling. The \u003cstrong\u003egenuine Goodman OEM 20201901\u003c\/strong\u003e arrives pre-sized with the correct bore and connectors, ensuring a secure seal and uninterrupted drainage.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Power down the furnace, detach the worn hose, route the new tube along the original path, and seat both ends fully. Roughly 10 minutes with basic hand tools. Confirm the condensate trap is clear while you're in there.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057456300403,"sku":"GOODMAN-2346","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201901-1-1784915206382.jpg?v=1784915207"},{"product_id":"oem-goodman-condensate-drain-trap-for-acss920804cnaa-furnace-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACSS920804CNAA Furnace — 0161F00046","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 0161F00046 Condensate Drain Trap\u003c\/strong\u003e is a genuine OEM drainage component for the \u003cstrong\u003eGoodman ACSS920804CNAA\u003c\/strong\u003e high-efficiency gas furnace and compatible models. In a condensing furnace, acidic condensate forms in the secondary heat exchanger and must drain freely while maintaining a proper water seal. This trap routes that condensate away and prevents flue gases from escaping or pressure-switch readings from drifting. A cracked, clogged, or missing trap is a frequent cause of pressure-switch lockouts, water leaks, and intermittent furnace shutdowns.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 0161F00046\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Maintains condensate water seal and drainage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment:\u003c\/strong\u003e High-efficiency (condensing) gas furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit:\u003c\/strong\u003e Goodman \/ Amana ACSS920804CNAA and related furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Molded plastic with hose-barb \/ inlet ports\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003egenuine Goodman OEM\u003c\/strong\u003e trap is molded to the exact port sizes, seal height, and mounting geometry of your furnace's drainage system. Generic or universal traps often require adapters and can produce an incorrect water column, leading to pressure-switch faults. OEM bolts in and seals correctly the first time.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate.\u003c\/strong\u003e Power off the furnace, disconnect the condensate hoses and pressure-switch tubing, remove the old trap, and fit the new one with fresh clamps. Prime the trap with water before restart. Plan on 20–30 minutes; keep a towel handy for residual condensate.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057458200947,"sku":"GOODMAN-0161F00046","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785040079679.jpg?v=1785040080"},{"product_id":"oem-goodman-condensate-drain-trap-for-acss961005cnaa-0161f00046-1","title":"OEM Goodman Condensate Drain Trap for ACSS961005CNAA — 0161F00046","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0161F00046 Condensate Drain Trap\u003c\/strong\u003e is a genuine OEM component for the high-efficiency Goodman \u003cstrong\u003eACSS961005CNAA\u003c\/strong\u003e furnace. In a 96% AFUE condensing furnace, the drain trap captures acidic condensate from the secondary heat exchanger and seals the drain line against flue-gas spillage. A cracked or clogged trap is one of the most common causes of pressure-switch lockouts and water leaks under the unit.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 0161F00046\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded, corrosion-resistant plastic\u003c\/li\u003e\n\u003cli\u003eFunction: Condensate drainage + flue-gas seal\u003c\/li\u003e\n\u003cli\u003eFits: Goodman ACSS961005CNAA condensing furnaces\u003c\/li\u003e\n\u003cli\u003eReplacement: Direct OEM fit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM 0161F00046\u003c\/strong\u003e is molded to match the furnace's drain ports and pressure-switch tubing exactly. Universal traps often require adapters and can leak or alter the pressure-switch reference, triggering fault codes. OEM ensures a leak-free, code-correct seal.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (3\/5)\u003c\/strong\u003e — Requires disconnecting and re-priming drain and pressure-switch tubing. Power off the furnace, capture residual condensate, and confirm the trap is filled with water before restarting.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057464590707,"sku":"GOODMAN-2426","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-0161F00046-1-1785040114930.jpg?v=1785040116"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acv90704cxbb-20201803","title":"OEM Goodman Condensate Drain Hose Tube for ACV90704CXBB — 20201802","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20201802 Condensate Drain Hose Tube\u003c\/strong\u003e is a genuine OEM replacement designed for the \u003cstrong\u003eACV90704CXBB\u003c\/strong\u003e high-efficiency gas furnace and compatible Goodman\/Amana models. This hose routes acidic condensate from the heat exchanger and drain trap to the drain line. Brittle, cracked, or kinked hoses cause leaks, water pooling, and pressure-switch faults — replacing the tube restores reliable drainage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Type: Condensate Drain Hose Tube\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20201802\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACV90704CXBB (and select Goodman\/Amana furnaces)\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman \/ Amana\u003c\/li\u003e\n\u003cli\u003eApplication: Condensate routing on condensing furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Flexible, corrosion-resistant tubing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine OEM hose\u003c\/strong\u003e is pre-formed to the correct length and bend radius for your furnace, ensuring proper drainage flow. Generic bulk tubing may kink or sit at the wrong angle, trapping water. OEM removes the guesswork.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Slip off the old hose, route and attach the new one, and secure the clamps. Most installs take under 15 minutes — a perfect DIY repair.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057469964659,"sku":"GOODMAN-2458","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917859647.jpg?v=1784917861"},{"product_id":"oem-goodman-drain-angle-fitting-for-acv90704cxbb-20214204","title":"OEM Goodman Drain Angle Fitting for ACV90704CXBB — 20214203","description":"\u003ch2\u003eGoodman 20214203 Condensate Drain Angle Fitting\u003c\/h2\u003e\u003cp\u003eThe Goodman 20214203 is a genuine OEM drain angle fitting designed for the \u003cstrong\u003eACV90704CXBB\u003c\/strong\u003e high-efficiency furnace and related Goodman\/Amana condensing models. This angled elbow redirects condensate from the heat exchanger and inducer drain ports into the drain hose and trap, maintaining the proper downhill slope the system needs to drain by gravity. A worn, cracked, or improperly angled fitting causes water to back up, triggering condensate-overflow and pressure-switch faults that shut the furnace down.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Condensate drain angle \/ elbow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFits:\u003c\/strong\u003e Goodman ACV90704CXBB and compatible 90%+ furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Factory barbed\/slip fit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Corrosion-resistant molded fitting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart type:\u003c\/strong\u003e OEM replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis genuine Goodman OEM angle is molded to the precise diameter and bend the furnace's drain layout requires, ensuring a leak-free, gravity-fed connection. Generic fittings frequently mismatch the port size or angle, forcing adapters that introduce leak points and disrupt drainage. On a condensing furnace where reliable drainage is a safety interlock, the OEM fitting is the dependable choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (DIY-friendly).\u003c\/strong\u003e Turn off power to the furnace, detach the drain hose, remove the old angle fitting, and press the new 20214203 into place at the original orientation before reconnecting the hose. The job takes about 10 minutes with no special tools. Verify the fitting maintains a continuous downhill slope and test for free-flowing condensate before restarting.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057470062963,"sku":"GOODMAN-2461","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-angle-20214203-1-1784920083078.jpg?v=1784920084"},{"product_id":"oem-goodman-rubber-coupling-for-acv90905dxba-furnace-10254304","title":"OEM Goodman Rubber Coupling for ACV90905DXBA Furnace — 10254303","description":"\u003ch2\u003eGoodman 10254303 Rubber Coupling\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e10254303 Rubber Coupling\u003c\/strong\u003e is a genuine OEM sealing component engineered for the \u003cstrong\u003eACV90905DXBA\u003c\/strong\u003e gas furnace and compatible Goodman\/Amana models. This flexible coupling joins drain and condensate tubing inside the furnace cabinet, creating a leak-tight, vibration-dampening connection that protects the heat exchanger area and surrounding cabinet from moisture damage. A cracked or hardened coupling is one of the most common causes of nuisance condensate leaks on high-efficiency furnaces.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenuine Goodman OEM part #10254303\u003c\/li\u003e\n\u003cli\u003ePart type: Rubber coupling \/ drain seal\u003c\/li\u003e\n\u003cli\u003eMaterial: EPDM-style heat- and moisture-resistant rubber\u003c\/li\u003e\n\u003cli\u003eApplication: Condensate \/ drain line connection\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACV90905DXBA gas furnace\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM\u003c\/strong\u003e coupling is molded to factory durometer and dimensions for a guaranteed slip-fit seal and full furnace warranty compliance. A \u003cstrong\u003egeneric\u003c\/strong\u003e equivalent may save a few cents but can vary in inner diameter and rubber hardness, leading to slow drips or premature cracking. For a part this inexpensive and critical, OEM is the smart choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Power down the furnace, slide the old coupling off the drain stubs, and press the new one into place — no tools or special skills required. Most homeowners and technicians complete this in under five minutes.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057470226803,"sku":"GOODMAN-2465","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-10254303-1-1785178869095.jpg?v=1785178870"},{"product_id":"oem-goodman-condensate-drain-trap-for-acv90905dxba-20171702","title":"OEM Goodman Condensate Drain Trap for ACV90905DXBA — 20171701","description":"\u003ch2\u003eGoodman 20171701 Condensate Drain Trap\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e20171701 Drain Trap\u003c\/strong\u003e is a genuine OEM condensate trap built for the \u003cstrong\u003eACV90905DXBA\u003c\/strong\u003e high-efficiency gas furnace and compatible Goodman\/Amana models. The trap collects acidic condensate from the secondary heat exchanger and routes it to the drain while maintaining a water seal that blocks flue gases from escaping into the cabinet. A cracked, clogged, or missing trap triggers pressure-switch faults, water leaks, and intermittent furnace lockouts.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenuine Goodman OEM part #20171701\u003c\/li\u003e\n\u003cli\u003ePart type: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eApplication: High-efficiency (condensing) furnace drainage\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded corrosion-resistant polymer\u003c\/li\u003e\n\u003cli\u003eCompatible model: ACV90905DXBA gas furnace\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM\u003c\/strong\u003e trap matches the exact port spacing, height, and internal baffle design so the water seal and pressure-switch readings stay within spec. \u003cstrong\u003eGeneric\u003c\/strong\u003e or universal traps frequently require adapters and can throw false pressure-switch errors. For reliable operation on a condensing furnace, OEM fit matters.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (2\/5).\u003c\/strong\u003e Power down the furnace, disconnect the inlet\/outlet drain hoses, remove mounting screws, and install the new trap — then prime it with water before restarting. Inspect hoses for clogs while access is open. Allow 20–30 minutes.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057470292339,"sku":"GOODMAN-2467","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-20171701-1-1785037424157.jpg?v=1785037425"},{"product_id":"oem-goodman-23-inch-condensate-drain-hose-tube-for-acv90905dxba-20201903","title":"OEM Goodman 23 inch Condensate Drain Hose Tube for ACV90905DXBA — 20201902","description":"\u003ch2\u003eGoodman 20201902 23\" Condensate Drain Hose Tube\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e20201902\u003c\/strong\u003e is a genuine OEM 23-inch condensate drain hose tube engineered for the \u003cstrong\u003eACV90905DXBA\u003c\/strong\u003e high-efficiency condensing gas furnace. In a 90%+ AFUE furnace, the secondary heat exchanger and inducer assembly produce acidic condensate that must drain cleanly — a cracked, brittle, or clogged drain hose is one of the most common causes of nuisance lockouts, water leaks, and pressure-switch faults. Replacing it with the correct factory-spec tube restores proper drainage and protects surrounding components from water damage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLength: 23 inches\u003c\/li\u003e\n\u003cli\u003eApplication: Furnace condensate drainage\u003c\/li\u003e\n\u003cli\u003eCompatible model: Goodman ACV90905DXBA (verify against your unit's parts list)\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20201902\u003c\/li\u003e\n\u003cli\u003eMaterial: Flexible chemical-resistant tubing rated for acidic condensate\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis \u003cstrong\u003egenuine OEM Goodman\u003c\/strong\u003e hose is cut to the exact length and diameter the ACV90905DXBA was designed around, ensuring leak-free connections at both fittings. Generic universal tubing often requires field trimming, can kink at factory routing bends, and may not be rated for the low pH of condensing-furnace condensate, leading to premature failure. For a critical drainage path, the OEM part is the reliable choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5)\u003c\/strong\u003e — Typically a slip-on hose replacement secured with clamps. Turn off power and gas, disconnect the old hose, route the new tube along the same path, and reattach the clamps. Most homeowners with basic tools can complete this in 10–15 minutes.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057470816627,"sku":"GOODMAN-2470","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201902-1-1784912648170.jpg?v=1784912649"},{"product_id":"oem-goodman-drain-hose-tube-for-acv90905dxbb-20201803","title":"OEM Goodman Drain Hose Tube for ACV90905DXBB — 20201802","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e20201802 Drain Hose Tube\u003c\/strong\u003e is a genuine OEM condensate drain component engineered for the Goodman \u003cstrong\u003eACV90905DXBB\u003c\/strong\u003e furnace and compatible high-efficiency gas furnace platforms. This flexible drain tube routes condensate away from the secondary heat exchanger and collector box, helping prevent water backup, freeze-ups, and nuisance pressure-switch lockouts that occur when drainage is restricted.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 20201802\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain hose tube\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (OEM)\u003c\/li\u003e\n\u003cli\u003eEquipment: 90%+ AFUE gas furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Fit: ACV90905DXBB\u003c\/li\u003e\n\u003cli\u003eMaterial: Heat- and corrosion-resistant tubing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eGenuine OEM tubing is molded to the exact bend radius, length, and connection diameter Goodman specifies, so it seats on the collector box and drain trap without leaks. Generic aftermarket hose often requires trimming and can kink or loosen over time, leading to slow leaks and water-sensor faults. For reliable condensate management, OEM is the safe choice.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5)\u003c\/strong\u003e — Power down the furnace, remove the worn hose, slide on the replacement, and secure the clamp. Most homeowners complete this in under 15 minutes. No special tools required.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057471242611,"sku":"GOODMAN-2480","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917875374.jpg?v=1784917876"},{"product_id":"oem-goodman-condensate-drain-angle-for-acv90905dxbb-20214204","title":"OEM Goodman Condensate Drain Angle for ACV90905DXBB — 20214203","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e20214203 Drain Angle\u003c\/strong\u003e is a genuine OEM condensate elbow fitting for the Goodman \u003cstrong\u003eACV90905DXBB\u003c\/strong\u003e furnace and related 90%+ AFUE models. This angled connector redirects the condensate line at the collector box or trap, maintaining proper drainage geometry in tight furnace cabinets so water flows freely instead of pooling against the heat exchanger.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 20214203\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain angle \/ elbow fitting\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (OEM)\u003c\/li\u003e\n\u003cli\u003eEquipment: 90%+ AFUE gas furnaces\u003c\/li\u003e\n\u003cli\u003ePrimary Fit: ACV90905DXBB\u003c\/li\u003e\n\u003cli\u003eMaterial: Corrosion-resistant molded fitting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis OEM angle is molded to Goodman's exact bend and barb dimensions, mating perfectly with the factory drain hose and trap for a watertight joint. Generic elbows often differ slightly in barb size and angle, producing slow leaks and condensate-sensor faults. The genuine part ensures a clean, drip-free connection.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5)\u003c\/strong\u003e — Cut power, slip the angle between the hose sections, and secure the clamps. A quick 10–15 minute repair requiring no special tools.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057471340915,"sku":"GOODMAN-2483","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-angle-20214203-1-1784920098240.jpg?v=1784920099"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acvc80805cxca-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACVC80805CXCA — 0128F00006","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is a genuine OEM venting component engineered for the \u003cstrong\u003eACVC80805CXCA\u003c\/strong\u003e 80% AFUE gas furnace. This transition piece directs combustion byproducts from the heat exchanger into the flue\/vent system, maintaining the correct draft path and proper clearances for safe, code-compliant operation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Chimney \/ flue transition bottom\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 0128F00006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Model:\u003c\/strong\u003e ACVC80805CXCA (Goodman\/Amana furnace)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Flue \u0026amp; Vent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Galvanized sheet metal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit:\u003c\/strong\u003e Direct OEM replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis is a \u003cstrong\u003efactory OEM\u003c\/strong\u003e part with exact dimensions and mounting holes that match the original furnace cabinet. Generic or universal venting transitions often require trimming or shimming and can compromise draft and flue clearances. For a safe, leak-free seal we recommend the OEM component.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate.\u003c\/strong\u003e Requires partial furnace disassembly and sheet-metal handling. Always shut off gas and power before service and verify proper draft after installation. Professional installation recommended.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057478549875,"sku":"GOODMAN-2640","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-2640.jpg?v=1783394061"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acvc81005cxbc-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACVC81005CXBC — 0128F00006","description":"\u003cp\u003eThe genuine Goodman \u003cstrong\u003e0128F00006\u003c\/strong\u003e chimney transition bottom is the OEM flue\/vent component for the \u003cstrong\u003eACVC81005CXBC\u003c\/strong\u003e gas furnace and compatible Goodman\/Amana models. This transition piece adapts the furnace's flue collar to the vent connector, channeling combustion byproducts away from the heat exchanger and out to the chimney or vent system. A correctly fitted transition maintains proper draft and prevents dangerous flue-gas spillage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 0128F00006\u003c\/li\u003e\n\u003cli\u003eType: Chimney\/flue transition (bottom section)\u003c\/li\u003e\n\u003cli\u003eFunction: Adapts furnace flue outlet to vent connector\u003c\/li\u003e\n\u003cli\u003eFits: Goodman ACVC81005CXBC and compatible 80% AFUE furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Corrosion-resistant galvanized steel\u003c\/li\u003e\n\u003cli\u003eApplication: Natural-draft \/ induced-draft venting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe OEM transition is formed to match your furnace cabinet's exact flue location and dimensions, ensuring a tight, properly sealed connection. A generic or fabricated piece can leave gaps that disrupt draft and allow exhaust leakage. For a flue component handling combustion gases, OEM fit and fitment integrity matter for safety.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty: Moderate\u003c\/h3\u003e\u003cp\u003eShut off power and gas and allow the flue to cool. Disconnect the vent connector, remove the old transition, and fit the replacement to the flue collar, securing with sheet-metal screws and sealing per code. After install, verify proper draft and check for spillage at the draft hood with the furnace running. Professional or code-compliant installation is recommended for venting work.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057478844787,"sku":"GOODMAN-2648","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-2648.jpg?v=1783394063"},{"product_id":"oem-goodman-chimney-transition-bottom-for-acvc81005cxca-0128f00006-1","title":"OEM Goodman Chimney Transition Bottom for ACVC81005CXCA — 0128F00006","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e0128F00006 Chimney Transition Bottom\u003c\/strong\u003e is the genuine OEM flue\/vent component for the \u003cstrong\u003eACVC81005CXCA\u003c\/strong\u003e gas furnace. This transition piece connects the furnace heat exchanger outlet to the venting system, channeling combustion byproducts safely toward the chimney or flue. A properly fitted transition maintains correct draft, prevents flue gas spillage, and protects against condensation and corrosion at the vent connection.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePart Number: 0128F00006\u003c\/li\u003e\n\u003cli\u003eType: Chimney transition bottom (flue\/vent)\u003c\/li\u003e\n\u003cli\u003eMaterial: Galvanized steel\u003c\/li\u003e\n\u003cli\u003eFits: Goodman ACVC81005CXCA gas furnace\u003c\/li\u003e\n\u003cli\u003eFunction: Connects heat exchanger outlet to venting system\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eOEM Goodman transitions match the exact flange pattern, dimensions, and gasket seat of your furnace, ensuring a leak-free seal. Generic or fabricated substitutes risk gaps that allow flue gas leakage — a safety hazard. For any venting component, the OEM part is the safe choice.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — requires disconnecting the vent pipe and resealing the transition. Always verify draft and check for spillage with a combustion analyzer after installation.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057479369075,"sku":"GOODMAN-2666","price":11.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-flue-vent-chimney-transition-GOODMAN-2666.jpg?v=1783394065"},{"product_id":"oem-goodman-condensate-drain-trap-for-acvc90704cxaa-20171702","title":"OEM Goodman Condensate Drain Trap for ACVC90704CXAA — 20171701","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20171701 Condensate Drain Trap\u003c\/strong\u003e is the genuine OEM trap assembly for the \u003cstrong\u003eACVC90704CXAA\u003c\/strong\u003e 96% AFUE condensing gas furnace. High-efficiency furnaces produce acidic condensate from the secondary heat exchanger, and this trap routes that water to the drain while sealing the system against flue-gas leakage. A cracked, clogged, or aged trap is a frequent source of water leaks, pressure-switch lockouts, and nuisance error codes.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eType: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eApplication: 90%+ AFUE condensing furnace\u003c\/li\u003e\n\u003cli\u003eOEM Part Number: 20171701\u003c\/li\u003e\n\u003cli\u003eFits: Goodman ACVC90704CXAA furnace\u003c\/li\u003e\n\u003cli\u003eBrand: Genuine Goodman OEM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOEM Goodman\u003c\/strong\u003e trap is molded to the exact port spacing and inlet\/outlet geometry of the furnace cabinet, so it seats correctly and seals the first time. \u003cstrong\u003eGeneric\u003c\/strong\u003e universal traps exist at a lower price but often require adapters and extra tubing, and a poor seal on a condensing furnace can trigger pressure-switch faults. For correct fit, the OEM part is the safe choice.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (2\/5).\u003c\/strong\u003e Requires disconnecting condensate tubing, removing the old trap, and reconnecting with proper seals. Flush the trap and check for blockage during install. Budget 20–30 minutes; have a towel ready for residual condensate.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057479696755,"sku":"GOODMAN-2676","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-20171701-1-1785037438248.jpg?v=1785037439"},{"product_id":"oem-goodman-condensate-drain-angle-for-acvc90704cxaa-furnace-20214204","title":"OEM Goodman Condensate Drain Angle for ACVC90704CXAA Furnace — 20214203","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20214203 Condensate Drain Angle\u003c\/strong\u003e is a genuine OEM replacement component engineered for the \u003cstrong\u003eACVC90704CXAA\u003c\/strong\u003e high-efficiency condensing gas furnace. This molded drain fitting routes acidic condensate produced during the combustion cycle safely away from the secondary heat exchanger and into the drain trap, preventing pooling, corrosion, and nuisance lockouts.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 20214203\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Condensate Drain Angle \/ Fitting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Model:\u003c\/strong\u003e ACVC90704CXAA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment:\u003c\/strong\u003e 90%+ AFUE Condensing Gas Furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Corrosion-resistant molded polymer\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis is a \u003cstrong\u003egenuine Goodman OEM part\u003c\/strong\u003e, molded to the exact angle and port dimensions of the original. Generic or universal drain fittings often leak at the seal or fail to seat properly in the collector box, leading to water damage and warranty issues. Choosing OEM guarantees a leak-free, drop-in fit.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e A basic hand-tool swap. Power down the furnace, drain the existing line, remove the old fitting, seat the new angle, and re-secure the hose. Most homeowners and technicians complete this in under 15 minutes. Always confirm the condensate trap is clear during replacement.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057479991667,"sku":"GOODMAN-2680","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-angle-20214203-1-1784920106153.jpg?v=1784920107"},{"product_id":"oem-goodman-condensate-drain-trap-for-acvc90905dxaa-20171702","title":"OEM Goodman Condensate Drain Trap for ACVC90905DXAA — 20171701","description":"\u003ch2\u003eGoodman 20171701 Condensate Drain Trap\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e20171701\u003c\/strong\u003e is a genuine OEM condensate drain trap designed for the \u003cstrong\u003eACVC90905DXAA\u003c\/strong\u003e high-efficiency condensing gas furnace. In a 90%+ AFUE furnace, the secondary heat exchanger pulls so much heat from the flue gas that water vapor condenses out. This trap collects that acidic condensate, channels it to the drain line, and maintains a water seal that prevents flue gas and pressure leaks from escaping into the cabinet — protecting the inducer and pressure-switch circuit.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eManufacturer: Goodman (OEM)\u003c\/li\u003e\n\u003cli\u003ePart Number: 20171701\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eFunction: Condensate collection, drainage \u0026amp; flue-gas seal\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded chemical-resistant polymer\u003c\/li\u003e\n\u003cli\u003eEquipment: Condensing gas furnace\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe OEM trap matches Goodman's exact port locations, hose diameters, and float\/seal geometry, so it drops in without adapters and seals correctly the first time. Generic traps frequently misalign with the inducer and pressure ports, causing leaks and recurring pressure-switch faults. For a clean, leak-free repair, choose OEM.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModerate (2\/5).\u003c\/strong\u003e Disconnect the hoses, swap the trap, and reconnect — about 20–30 minutes. Shut off power and gas, then prime the trap with water before restarting so the seal holds immediately.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057480647027,"sku":"GOODMAN-2693","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-20171701-1-1785037445414.jpg?v=1785037446"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acvc90905dxaa-20201803","title":"OEM Goodman Condensate Drain Hose Tube for ACVC90905DXAA — 20201802","description":"\u003ch2\u003eGoodman 20201802 Condensate Drain Hose Tube\u003c\/h2\u003e\u003cp\u003eThe Goodman \u003cstrong\u003e20201802\u003c\/strong\u003e is a genuine OEM condensate drain hose tube engineered for the \u003cstrong\u003eACVC90905DXAA\u003c\/strong\u003e high-efficiency condensing gas furnace. This flexible tube carries acidic condensate between the secondary heat exchanger, collector box, drain trap, and outlet. Pre-formed to the correct length and bend radius, it routes condensate without kinks that would cause backups, pressure-switch faults, or water spilling inside the furnace cabinet.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eManufacturer: Goodman (OEM)\u003c\/li\u003e\n\u003cli\u003ePart Number: 20201802\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eFunction: Routes acidic condensate between trap and drain ports\u003c\/li\u003e\n\u003cli\u003eMaterial: Flexible chemical-resistant tubing\u003c\/li\u003e\n\u003cli\u003eEquipment: Condensing gas furnace\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe OEM hose is cut to the exact length and inner diameter Goodman specifies, so it slips onto the factory barbs and clamps for a secure, leak-free seal. Generic tubing is often the wrong bore or stiffness, leading to loose connections, kinks, and recurring condensate leaks. Use the genuine part for a reliable fit.\u003c\/p\u003e\u003ch3\u003eInstall Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Slide the hose onto the fittings, secure with the existing clamps, and you're done in under 10 minutes. Shut off power and gas first, and confirm the hose runs downhill to the drain with no sags or kinks.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057480679795,"sku":"GOODMAN-2694","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917890447.jpg?v=1784917891"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acvc90905dxaa-20201902","title":"OEM Goodman Condensate Drain Hose Tube for ACVC90905DXAA — 20201901","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e20201901 Condensate Drain Hose Tube\u003c\/strong\u003e is a genuine OEM replacement part designed for the Goodman \u003cstrong\u003eACVC90905DXAA\u003c\/strong\u003e high-efficiency condensing gas furnace. This flexible drain tube routes acidic condensate away from the secondary heat exchanger and collector box, keeping the drainage path clear and preventing nuisance pressure-switch lockouts caused by a clogged or cracked line.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 20201901\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Condensate drain hose tube\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Goodman (genuine OEM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Model:\u003c\/strong\u003e ACVC90905DXAA condensing furnace\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Chemical-resistant condensate-grade tubing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Drainage \/ condensate management\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis is a factory-original Goodman component built to the exact length, diameter, and durometer the furnace was engineered around. Generic aftermarket tubing is often the wrong inner diameter or wall thickness, which can kink, leak at the barbed fittings, or degrade prematurely against corrosive condensate. Choosing the OEM 20201901 guarantees a leak-free, drop-in fit with no trimming or adapters.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (DIY-friendly).\u003c\/strong\u003e Replacement typically takes 10–15 minutes with basic hand tools. Power down the furnace, disconnect the old tube from the collector box and drain trap, slide the new 20201901 onto the existing barbed fittings, and confirm a snug, leak-free seat. Always run the unit afterward and inspect for drips. If you are not comfortable working around the heat exchanger and condensate trap, consult a licensed HVAC technician.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057480712563,"sku":"GOODMAN-2695","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201901-1-1784915265594.jpg?v=1784915266"},{"product_id":"oem-goodman-condensate-drain-trap-for-acvc90905dxab-furnace-20171702","title":"OEM Goodman Condensate Drain Trap for ACVC90905DXAB Furnace — 20171701","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20171701 condensate drain trap\u003c\/strong\u003e is a genuine OEM replacement component engineered for the \u003cstrong\u003eACVC90905DXAB\u003c\/strong\u003e high-efficiency (90%+ AFUE) gas furnace. As a condensing furnace produces acidic water vapor during combustion, this drain trap captures and routes condensate safely away from the heat exchanger and inducer assembly, while its water seal blocks flue gases from escaping into the cabinet. A cracked, clogged, or missing trap is one of the most common causes of nuisance lockouts and water leakage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20171701\u003c\/li\u003e\n\u003cli\u003eComponent: Condensate drain trap assembly\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACVC90905DXAB (90% AFUE variable-speed gas furnace)\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman\u003c\/li\u003e\n\u003cli\u003eEquipment Type: Gas Furnace\u003c\/li\u003e\n\u003cli\u003eMaterial: Corrosion-resistant molded plastic\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis is the factory-original Goodman part, guaranteeing the exact port spacing, water-column seal depth, and mounting orientation specified for your furnace. Generic or universal traps often require adapters and can fail to maintain the proper trap seal, leading to pressure-switch faults. Choosing OEM eliminates guesswork and protects your warranty-spec performance.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (DIY-friendly).\u003c\/strong\u003e Replacement typically takes 15-30 minutes with basic hand tools. Power off the furnace, disconnect the inlet and outlet drain hoses, remove the old trap, install the new 20171701, prime it with water, and reconnect. We recommend flushing the drain line during service.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057481073011,"sku":"GOODMAN-2705","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-trap-20171701-1-1785037452595.jpg?v=1785037453"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acvc950714cxaa-20201803","title":"OEM Goodman Condensate Drain Hose Tube for ACVC950714CXAA — 20201802","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e20201802 Condensate Drain Hose Tube\u003c\/strong\u003e is a genuine OEM replacement part engineered for the Goodman \u003cstrong\u003eACVC950714CXAA\u003c\/strong\u003e high-efficiency condensing gas furnace and other compatible 90%+ AFUE models. This flexible drain tube routes acidic condensate away from the heat exchanger and secondary coil, protecting your furnace cabinet and internal components from corrosion and water damage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20201802\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain hose \/ tube\u003c\/li\u003e\n\u003cli\u003eMaterial: Heat- and corrosion-resistant tubing\u003c\/li\u003e\n\u003cli\u003eApplication: 90%+ AFUE condensing furnaces\u003c\/li\u003e\n\u003cli\u003eCompatibility: Goodman ACVC950714CXAA and related models\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (Genuine OEM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eGenuine OEM tubing is molded to the exact length, bend radius, and durometer specified by Goodman, ensuring a leak-free seal at every connection point. Generic universal hose may require cutting and can kink at factory bends, leading to condensate backup and nuisance pressure-switch lockouts. For reliable drainage we recommend the OEM part.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Most homeowners can replace this drain hose in under 15 minutes with no special tools—simply slide off the old tube and press the new one onto the fitting. Always disconnect power before servicing your furnace.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057481892211,"sku":"GOODMAN-2720","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201802-1-1784917906104.jpg?v=1784917907"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acvc950714cxaa-20201902","title":"OEM Goodman Condensate Drain Hose Tube for ACVC950714CXAA — 20201901","description":"\u003cp\u003eThe Goodman \u003cstrong\u003e20201901 Condensate Drain Hose Tube\u003c\/strong\u003e is a genuine OEM replacement designed for the Goodman \u003cstrong\u003eACVC950714CXAA\u003c\/strong\u003e condensing gas furnace and compatible high-efficiency models. This larger-diameter drain assembly carries condensate from the secondary heat exchanger and collector box to the drain trap, keeping your furnace running dry and lockout-free through the heating season.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20201901\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain hose \/ tube assembly\u003c\/li\u003e\n\u003cli\u003eMaterial: Heat- and acid-resistant tubing\u003c\/li\u003e\n\u003cli\u003eApplication: 90%+ AFUE condensing furnaces\u003c\/li\u003e\n\u003cli\u003eCompatibility: Goodman ACVC950714CXAA and related models\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (Genuine OEM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThis OEM hose arrives pre-formed with the correct bends and connection collars to mate directly with the furnace's collector box and trap. Generic tubing is sold by the foot and lacks the molded fittings, so it can leak at slip joints or collapse under negative pressure. The OEM part guarantees a factory-correct, sealed condensate path.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e Replacement takes 15–20 minutes. Disconnect power, remove the spring clamps, swap the hose, and re-secure. No special tools required. Test for leaks after restoring power and running a heat cycle.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057481924979,"sku":"GOODMAN-2721","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201901-1-1784915280726.jpg?v=1784915281"},{"product_id":"oem-goodman-condensate-drain-angle-for-acvc950714cxab-20214204","title":"OEM Goodman Condensate Drain Angle for ACVC950714CXAB — 20214203","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20214203 Condensate Drain Angle\u003c\/strong\u003e is a genuine OEM replacement part engineered for the \u003cstrong\u003eACVC950714CXAB\u003c\/strong\u003e high-efficiency gas furnace and other compatible Goodman\/Amana condensing models. This fitting routes condensate away from the heat exchanger and collector box, preventing pooling, corrosion, and nuisance pressure-switch lockouts caused by blocked or improperly angled drainage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20214203\u003c\/li\u003e\n\u003cli\u003eType: Condensate drain angle \/ elbow fitting\u003c\/li\u003e\n\u003cli\u003eCompatible Equipment: Goodman ACVC950714CXAB and related 96% AFUE condensing furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Molded condensate-resistant polymer\u003c\/li\u003e\n\u003cli\u003eBrand: Goodman (OEM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eOur \u003cstrong\u003eOEM Goodman 20214203\u003c\/strong\u003e is dimensionally identical to the factory part, ensuring leak-free seating in the existing drain port. Generic universal fittings often require adapters or trimming and risk a poor seal, which can lead to condensate leaks and water damage. For condensing furnaces, an exact-fit drain component is the reliable choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (1\/5).\u003c\/strong\u003e A basic hand-tool replacement most homeowners can complete in minutes. Power down the furnace, remove the old drain angle, seat the new fitting, and confirm a tight, leak-free connection before restoring power.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057482350963,"sku":"GOODMAN-2735","price":10.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-angle-20214203-1-1784920145000.jpg?v=1784920146"},{"product_id":"oem-goodman-condensate-drain-hose-tube-for-acvc950714cxac-20201902","title":"OEM Goodman Condensate Drain Hose Tube for ACVC950714CXAC — 20201901","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman 20201901 condensate drain hose tube\u003c\/strong\u003e is a genuine OEM replacement engineered for the \u003cstrong\u003eACVC950714CXAC\u003c\/strong\u003e high-efficiency condensing gas furnace. In a 95%+ AFUE furnace, the secondary heat exchanger produces acidic condensate that must be routed away cleanly — a cracked, brittle, or clogged drain tube leads to water pooling, nuisance pressure-switch lockouts, and potential overflow damage. This factory-spec hose restores proper drainage and a sealed, leak-free connection.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOEM Part Number: 20201901\u003c\/li\u003e\n\u003cli\u003eComponent: Condensate drain hose tube\u003c\/li\u003e\n\u003cli\u003eCompatible Model: ACVC950714CXAC and related ACVC95 series furnaces\u003c\/li\u003e\n\u003cli\u003eMaterial: Chemical-resistant flexible tubing for acidic condensate\u003c\/li\u003e\n\u003cli\u003eApplication: 95%+ AFUE condensing gas furnace\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOEM vs. Generic\u003c\/h3\u003e\u003cp\u003eThe genuine Goodman part is molded to the exact length, diameter, and bend radius the furnace cabinet requires, ensuring a drip-tight fit on the drain trap and inducer outlet. Generic aftermarket tubing often requires trimming or forcing, which can kink the line or break the seal and reintroduce the very leaks you're trying to fix. For a critical drainage path, OEM is the reliable choice.\u003c\/p\u003e\u003ch3\u003eInstallation Difficulty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eEasy (DIY-friendly).\u003c\/strong\u003e Power down the furnace, disconnect the worn hose at both ends, route the new tube, and secure the connections. Typically completed in 15–20 minutes with basic hand tools. Always confirm the drain trap is primed before returning the unit to service.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":63057482613107,"sku":"GOODMAN-2745","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-drain-hose-20201901-1-1784915295970.jpg?v=1784915297"}],"url":"https:\/\/nationalhvacparts.com\/collections\/heat-exchangers.oembed?page=15","provider":"National HVAC Parts","version":"1.0","type":"link"}