{"title":"Draft Inducer Motors","description":"\u003cp\u003eOEM draft inducer motors for gas furnaces. Venter motor and combustion blower replacements.\u003c\/p\u003e","products":[{"product_id":"pressure-switch-draft-inducer-0-50-w-c-n-o","title":"Pressure Switch Draft Inducer -0.50 W.C. N.O.","description":"\u003cdiv class=\"nhvac-product-page\"\u003e\n  \u003cdiv class=\"product-description section\"\u003e\u003cp\u003eThe draft inducer pressure switch monitors that the combustion exhaust is properly venting. Before allowing ignition, it verifies the draft inducer motor is creating sufficient negative pressure in the flue. If pressure is inadequate, it keeps the gas valve closed - a critical safety function to prevent carbon monoxide buildup.\u003c\/p\u003e\u003c\/div\u003e\n  \u003cdiv class=\"failure-symptoms section\"\u003e\n    \u003ch3\u003eSigns This Part Has Failed\u003c\/h3\u003e\n    \u003cdiv class=\"pd-symptoms\"\u003e\n\u003cdiv class=\"pd-symptom\"\u003e\n\u003cspan class=\"pd-symptom-icon\"\u003e!\u003c\/span\u003e\u003cspan\u003eFurnace inducer runs but ignition never happens\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-symptom\"\u003e\n\u003cspan class=\"pd-symptom-icon\"\u003e!\u003c\/span\u003e\u003cspan\u003ePressure switch fault code (Code 31\/33 on most boards)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-symptom\"\u003e\n\u003cspan class=\"pd-symptom-icon\"\u003e!\u003c\/span\u003e\u003cspan\u003eFlue or drain pan blocked with water or debris\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pd-symptom\"\u003e\n\u003cspan class=\"pd-symptom-icon\"\u003e!\u003c\/span\u003e\u003cspan\u003eSwitch diaphragm cracked or port tubing blocked\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"installation-guide section\"\u003e\n    \u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n    \u003cp\u003e\u003cstrong\u003eDifficulty:\u003c\/strong\u003e Moderate - test before replacing.\u003c\/p\u003e\n    \u003cdiv class=\"install-steps\"\u003e\n\u003cdiv class=\"install-step\"\u003e\n\u003cdiv class=\"step-num\"\u003e1\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePower Down Completely\u003c\/strong\u003e\u003cp\u003eTurn off power at the disconnect switch and the circuit breaker. Verify with a non-contact voltage tester. For gas systems, turn off the gas supply valve.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"install-step\"\u003e\n\u003cdiv class=\"step-num\"\u003e2\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eAccess the Component\u003c\/strong\u003e\u003cp\u003eRemove the access panel (2-4 screws). Locate the component inside the electrical or combustion section of the unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"install-step\"\u003e\n\u003cdiv class=\"step-num\"\u003e3\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePhotograph All Wiring\u003c\/strong\u003e\u003cp\u003eTake clear photos of every wire connection before touching anything. This is your reinstallation reference.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"install-step\"\u003e\n\u003cdiv class=\"step-num\"\u003e4\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eRemove the Failed Part\u003c\/strong\u003e\u003cp\u003eDisconnect wire terminals and remove mounting screws or brackets. Note the orientation of the old part for reference.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"install-step\"\u003e\n\u003cdiv class=\"step-num\"\u003e5\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eInstall the New Part\u003c\/strong\u003e\u003cp\u003eMount the new component in the same orientation. Reconnect all wires exactly as shown in your photos. Ensure all terminals are fully seated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"install-step\"\u003e\n\u003cdiv class=\"step-num\"\u003e6\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eRestore Power and Test\u003c\/strong\u003e\u003cp\u003eReplace access panel, restore power at breaker then disconnect. Test thermostat for full heating or cooling cycle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"pro-tip\"\u003e\n\u003cstrong\u003ePro Tip:\u003c\/strong\u003e Before replacing the switch, blow through the rubber port tubing to clear any condensate blockage - 40% of pressure switch faults are caused by a blocked tube, not a failed switch.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"compatibility section\"\u003e\n    \u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n    \u003cp\u003eCarrier, Bryant, Trane, Goodman, Amana, Lennox, Rheem, Ruud, York, Heil\u003c\/p\u003e\n    \u003ch3\u003eOEM Cross Reference\u003c\/h3\u003e\n    \u003ctable class=\"compat-table\"\u003e\n      \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003eCompatible Model Numbers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n      \u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHK06NB007, HK06NB009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSWT02543\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGoodman\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB1370188S, B1370146S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRheem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42-24025-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYork\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS1-02531099000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"product-faq section\"\u003e\n    \u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n    \u003cdiv class=\"faq-item\"\u003e\n\u003cstrong class=\"faq-q\"\u003eHow do I test a pressure switch?\u003c\/strong\u003e\u003cp class=\"faq-a\"\u003eUse a multimeter on continuity. A normally-open (N.O.) switch should be open at rest and close when the inducer is running. Blow gently into the port tube - you should hear\/feel it click closed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cstrong class=\"faq-q\"\u003eWhat does -0.50 W.C. mean?\u003c\/strong\u003e\u003cp class=\"faq-a\"\u003eThe switch closes (allows ignition) when the inducer creates at least 0.50 inches of water column negative pressure. Match this rating exactly when ordering a replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"nhvac-related-links\"\u003e\n\u003ch3\u003eShop Related Parts\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/pressure-switches\"\u003eShop All pressure-switches\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/carrier-parts\"\u003eShop All Carrier Parts\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/hvac-parts\"\u003eShop All HVAC Parts\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62608951345523,"sku":"HK06NB007-OEM","price":27.0,"currency_code":"USD","in_stock":true},{"title":"Replacement","offer_id":62608951378291,"sku":"HK06NB007-REP","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK06NB007-OEM.jpg?v=1782956758"},{"product_id":"carrier-py4gnab60090na-pressure-switch-h43sg3","title":"OEM Carrier Inducer Pressure Switch 0.18 WC for PY4GNAB60090NA","description":"\u003ch1\u003eOEM Carrier Inducer Draft Pressure Switch 0.18\" WC for Model PY4GNAB60090NA\u003c\/h1\u003e\u003cp\u003eThis OEM draft pressure proving switch is the factory-specified replacement for the \u003cstrong\u003eCarrier PY4GNAB60090NA\u003c\/strong\u003e packaged unit. The pressure switch monitors negative pressure created by the inducer motor to confirm proper draft before allowing the ignition sequence to proceed. When it fails or sticks open, the control board interprets it as a blocked flue or inducer fault — resulting in a no-heat lockout, repeated ignition attempts with no flame, or a fault code indicating a pressure switch error. Replacing this switch with the correct OEM part restores proper sequencing and safe operation.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 0.18\" W.C. (inches water column) set point | Draft\/inducer proving type | Single-port | Normally open | OEM Part # HK06WC061 (superseded by HK06MB061) | Cross-reference: Honeywell IS20224-5236\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM pressure switches are factory-calibrated to the exact 0.18\" W.C. trip point required by the PY4GNAB60090NA control board. Generic substitutes frequently operate outside tolerance, causing nuisance lockouts or — worse — failing to detect a true blocked-flue condition, creating a safety risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Shut off gas and power before servicing. Tools needed: 1\/4\" nut driver, flat-head screwdriver, and a short length of silicone tubing. Photograph hose routing and wiring before disconnecting. Inspect inducer hose port and tubing for cracks or blockages while you have access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; Shipping:\u003c\/strong\u003e 1-year OEM manufacturer warranty against defects. Orders placed before cutoff ship same business day from our warehouse — back in heat fast.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Fits Carrier model \u003cstrong\u003ePY4GNAB60090NA\u003c\/strong\u003e packaged unit. Also compatible with select Bryant and Payne models sharing the 0.18\" W.C. pressure switch specification — verify the W.C. rating on your existing switch's label before ordering. Our parts specialists are available to confirm fitment before you buy.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640318349683,"sku":"CARRIE-PY4GNAB60090NA-PRESSURE_SWITCH-HK06WC061","price":50.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640318382451,"sku":"CARRIE-PY4GNAB60090NA-PRESSURE_SWITCH-HK06WC061-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK06WC061-1-1785194843749.jpg?v=1785194845"},{"product_id":"carrier-py4gnab48130aa-pressure-switch-h43sg3","title":"OEM Carrier Draft Inducer Pressure Switch 0.18\" WC — PY4GNAB48130AA","description":"\u003ch1\u003eOEM Carrier Draft Inducer Pressure Switch 0.18\" WC for Model PY4GNAB48130AA\u003c\/h1\u003e\u003cp\u003eThis OEM Carrier draft inducer pressure switch (part HK06WC061, superseded by HK06MB061) is the factory-specified replacement for the \u003cstrong\u003eCarrier PY4GNAB48130AA\u003c\/strong\u003e packaged gas\/electric unit. The pressure switch is a critical safety component that monitors negative pressure created by the inducer motor to confirm it is operating at the correct RPM and establishing proper draft before allowing ignition. When this switch fails, the control board cannot verify safe venting conditions and will lock out the heating sequence entirely — leaving you with a no-heat call.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 0.18\" W.C. (water column) set point | Normally open (N.O.) configuration | Single-port design | OEM part HK06WC061 \/ superseded by HK06MB061 | Manufactured by Honeywell for Carrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine OEM-spec switch calibrated to the exact 0.18\" W.C. trip point required by the PY4GNAB48130AA control board. Off-spec generic switches with loose tolerances can cause nuisance lockouts or — more dangerously — allow ignition under improper draft conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Disconnect power before servicing. Tools needed: 1\/4\" nut driver, flathead screwdriver, multimeter (to confirm continuity when inducer is running). Label and remove the rubber hose port, swap the switch, confirm continuity at speed before restoring power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM warranty on parts. In-stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility Note:\u003c\/strong\u003e Direct OEM replacement for Carrier model \u003cstrong\u003ePY4GNAB48130AA\u003c\/strong\u003e packaged gas\/electric unit. Note that HK06WC061 has been superseded by Carrier part number HK06MB061 — both designations reference the same 0.18\" W.C. specification and are fulfilled as the current production part. Always verify the W.C. rating printed on your existing switch before ordering. Need help confirming fitment? Our HVAC parts specialists verify compatibility before you buy — \u003cstrong\u003eorder today and ship today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640319201651,"sku":"CARRIE-PY4GNAB48130AA-PRESSURE_SWITCH-HK06WC061","price":50.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640319234419,"sku":"CARRIE-PY4GNAB48130AA-PRESSURE_SWITCH-HK06WC061-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK06WC061-1-1785194851529.jpg?v=1785194852"},{"product_id":"carrier-py4geab48090na-pressure-switch-h43sg3","title":"OEM Carrier Inducer Pressure Switch 0.18\" WC for PY4GEAB48090NA","description":"\u003ch1\u003eOEM Carrier Draft Inducer Pressure Switch 0.18\" WC for Model PY4GEAB48090NA\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer pressure switch is the factory-specified replacement for the \u003cstrong\u003eCarrier PY4GEAB48090NA\u003c\/strong\u003e packaged unit. The pressure switch monitors negative pressure created by the inducer motor to verify proper venting before allowing the ignition sequence to proceed. When this switch fails or sticks open, the control board cannot confirm safe draft conditions — resulting in a no-heat lockout, a blinking fault code, or a system that attempts ignition repeatedly without firing.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 0.18\" Water Column (WC) set point | SPST (Single Pole, Single Throw) | Normally open | OEM part HK06WC061, superseded by HK06MB061 | Replaces Honeywell IS20224-5236\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM pressure switches are calibrated to exact water column tolerances at the factory. Generic aftermarket units can drift ±0.05\" WC or more, causing nuisance lockouts or — more dangerously — allowing ignition under unsafe draft conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Shut off power and gas before beginning. Tools needed: 1\/4\" nut driver, flathead screwdriver, manometer (for verification). Photograph hose and wiring connections before disconnecting. Verify hose for cracks or blockage before blaming the switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Direct OEM replacement for \u003cstrong\u003eCarrier PY4GEAB48090NA\u003c\/strong\u003e packaged units. Also fits select Bryant and Payne models sharing this 0.18\" WC draft pressure switch specification — confirm your unit's data plate and existing switch rating before ordering. Questions about fitment? Our HVAC parts team verifies compatibility before you buy — \u003cstrong\u003eorder today and ship today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640337158515,"sku":"CARRIE-PY4GEAB48090NA-PRESSURE_SWITCH-HK06WC061","price":50.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640337191283,"sku":"CARRIE-PY4GEAB48090NA-PRESSURE_SWITCH-HK06WC061-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK06WC061-1-1785195035735.jpg?v=1785195036"},{"product_id":"carrier-py3gnaa48130na-pressure-switch-h43sg3","title":"OEM Carrier Draft Inducer Pressure Switch for PY3GNAA48130NA","description":"\u003cdiv class=\"product-content\"\u003e\n\u003ch1\u003eOEM Carrier Draft Inducer Pressure Switch for PY3GNAA48130NA\u003c\/h1\u003e\n\u003cp\u003eThe draft inducer pressure switch is a safety device on your Carrier PY3GNAA48130NA furnace that confirms the inducer motor is actually moving combustion air before the burners are allowed to light. At the start of each heating cycle the inducer spins up, creating negative pressure that closes the switch; only then does the control board energize the igniter and open the gas valve. If venting is blocked or the inducer is weak, the switch stays open and ignition is prevented. When the switch itself fails — stuck open, corroded, or fed by a cracked sensing hose — the furnace runs the inducer but never lights, then locks out, usually flashing a pressure-switch fault code. A switch stuck closed is dangerous because it defeats the vent-safety check entirely.\n\nThis is a negative-pressure (vacuum) switch that trips at a specific water-column setpoint — commonly in the -0.40 to -0.70 in. W.C. range for this furnace family. The trip point is stamped on the switch body and must match your original. It uses a single-pole normally-open contact and a port for the silicone sensing tube.\n\nWhy OEM matters: a generic switch with the wrong setpoint either won't close on a healthy inducer (no heat) or closes too easily, bypassing the very fault it exists to catch. Matching the OEM water-column rating preserves the safety function.\n\nInstall difficulty: 2 of 5. Tools: 1\/4\" nut driver — and inspect the rubber sensing tube for cracks while you're in there. SAFETY: turn off power at the breaker before servicing, and never jumper or bypass a pressure switch to force the furnace to run.\n\nShips same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.\u003c\/p\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis part is compatible with Carrier model PY3GNAA48130NA. Always verify the part number against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose OEM?\u003c\/h2\u003e\n\u003cp\u003eOEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.\u003c\/p\u003e\n\u003ch2\u003eShipping \u0026amp; Returns\u003c\/h2\u003e\n\u003cp\u003eSame-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640445653363,"sku":"CARRIE-PY3GNAA48130NA-PRESSURE_SWITCH-HK06WC061","price":27.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640445686131,"sku":"CARRIE-PY3GNAA48130NA-PRESSURE_SWITCH-HK06WC061-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK06WC061_4df7ce4b-a589-4437-a712-524463de531e.jpg?v=1782914200"},{"product_id":"carrier-py1rja048115aawa-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ 4 MFD Capacitor HC30GB230 — PY1RJA048115A","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor HC30GB230 for Model PY1RJA048115AAWA\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor kit (part number \u003cstrong\u003eHC30GB230\u003c\/strong\u003e) is the factory-specified replacement for the \u003cstrong\u003eCarrier PY1RJA048115AAWA\u003c\/strong\u003e furnace. The draft inducer motor is responsible for purging combustion gases from the heat exchanger before and during the ignition sequence. When this motor fails or degrades, the furnace will enter a hard lockout — typically after the pressure switch fails to close, because the inducer can no longer produce adequate negative pressure. Common symptoms include a no-heat call, continuous lockout codes, the inducer spinning weakly or not at all, or the system short-cycling before ignition.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V Single Phase | 3450 RPM | CCWLE rotation | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mounting | Includes \u003cstrong\u003e4 µF 370V run capacitor\u003c\/strong\u003e and hall effect sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Numbers Covered:\u003c\/strong\u003e HC30GB230 (primary inducer motor kit) | P291-4554RS (dual run capacitor) | P291-0403 (single run capacitor) | P291-1503 (single run capacitor) — all factory-matched to PY1RJA048115AAWA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM assembly — motor windings, bearing grade, shaft tolerances, and hall effect sensor calibration are all factory-matched. Aftermarket draft inducer assemblies frequently ship with mismatched capacitor ratings or improperly balanced wheels, causing vibration, premature bearing failure, and pressure switch nuisance trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Shut off gas and power before beginning. Tools needed: 1\/4\" and 5\/16\" nut drivers, flat-head screwdriver, needle-nose pliers, multimeter, and manometer (recommended to verify pressure switch operation post-install). Photograph all wiring and flue connections before disassembly. Discharge the capacitor before handling. Note rotation direction (CCWLE) and confirm wheel seating before powering up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty on parts and workmanship. Ships same business day from our warehouse when ordered before cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003ePY1RJA048115AAWA\u003c\/strong\u003e gas furnace. This kit supersedes HC30GB231 and cross-references A.O. Smith #9626 and Fasco equivalent assemblies. Always verify voltage, HP, rotation, and shaft dimensions against your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you order if you have any questions.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640672801139,"sku":"CARRIE-PY1RJA048115AAWA-CAPACITOR-HC30GB230","price":375.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640672833907,"sku":"CARRIE-PY1RJA048115AAWA-CAPACITOR-HC30GB230-GEN","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HC30GB230-1-1786216844263.jpg?v=1786216845"},{"product_id":"carrier-py1rja048074aawb-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ Capacitor HC30GB230 — PY1RJA048074A","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor HC30GB230 for Model PY1RJA048074AAWB\u003c\/h1\u003e\u003cp\u003eThis is the factory OEM draft inducer motor and capacitor assembly for the \u003cstrong\u003eCarrier PY1RJA048074AAWB\u003c\/strong\u003e packaged unit. The draft inducer motor creates the negative pressure that proves combustion airflow before ignition is allowed to proceed. When this assembly fails, the integrated pressure switch cannot close, placing the furnace or packaged unit into a hard lockout — resulting in a no-heat call. Common symptoms include the inducer spinning slowly or not at all, the inducer running but the pressure switch never closing, or a system that attempts ignition and then locks out after repeated failed trials.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs \u0026amp; Included Parts:\u003c\/strong\u003e OEM assembly includes draft inducer motor and run capacitor | Replaces OEM part numbers \u003cstrong\u003eHC30GB230\u003c\/strong\u003e, \u003cstrong\u003eP291-4554RS\u003c\/strong\u003e (Dual Run Capacitor), \u003cstrong\u003eP291-0403\u003c\/strong\u003e (Single Run Capacitor), and \u003cstrong\u003eP291-1503\u003c\/strong\u003e (Single Run Capacitor) | Factory-matched voltage, RPM, and rotation direction for model PY1RJA048074AAWB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM motors are wound, balanced, and thermally protected to exact factory specifications. Generic aftermarket motors frequently ship with incorrect rotation direction, mismatched RPM, or undersized run capacitors — any of which can cause pressure switch failures, noisy operation, or premature burnout within one heating season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Discharge all capacitors before handling. Tools needed: 1\/4\" and 5\/16\" nut drivers, flat-blade and Phillips screwdrivers, multimeter, and draft-pressure manometer (recommended to verify pressure switch operation post-install). Always label and photograph all wiring harness connections before removal. Confirm flue outlet orientation before reinstalling the motor housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects in materials and workmanship. In-stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Direct OEM replacement for \u003cstrong\u003eCarrier model PY1RJA048074AAWB\u003c\/strong\u003e packaged units. Cross-references OEM numbers HC30GB230, P291-4554RS, P291-0403, and P291-1503. Always verify your unit's data plate voltage and motor specs before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — no guesswork, no returns.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640673194355,"sku":"CARRIE-PY1RJA048074AAWB-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640673227123,"sku":"CARRIE-PY1RJA048074AAWB-CAPACITOR-HC30GB230-GEN","price":159.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30GB230_b2bbfe37-fa19-4387-9b27-04cac30bdbea.jpg?v=1782914188"},{"product_id":"carrier-py1rja048074aawa-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ 45+5 MFD Capacitor HC30GB230 — PY1RJA048074A","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor (HC30GB230 \/ HC30GR231) for Model PY1RJA048074AAWA\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor with integrated run capacitor is the factory-specified replacement for the \u003cstrong\u003eCarrier PY1RJA048074AAWA\u003c\/strong\u003e packaged unit. The draft inducer creates the negative pressure differential needed to pull combustion air through the heat exchanger and vent flue gases safely outdoors before ignition begins. When the inducer motor fails, the pressure switch cannot prove airflow — resulting in ignition lockout, a no-heat condition, or repeated short-cycling fault codes. A failed or weakened run capacitor on the motor is a common root cause of inducer drag and bearing wear.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V | 1-Phase | 3450 RPM | CCWLE rotation | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mounting | Includes hall effect sensor and 4 MFD\/370VAC run capacitor | OEM Part HC30GB230 (superseded by HC30GR231)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM Carrier inducer motors are precision-balanced and hall-effect verified at the factory, ensuring the control board receives accurate RPM feedback. Generic motors frequently lack hall effect sensors or use inferior bearings, leading to premature failure and nuisance pressure switch lockouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — De-energize and lock out the unit before beginning. Disconnect the hall effect sensor harness, pressure switch tubing, and wiring leads before unbolting the motor. Tools needed: nut driver set, needle-nose pliers, multimeter, torque screwdriver. Confirm CCW rotation and verify pressure switch operation after installation. Photograph all wiring connections before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against manufacturing defects. Ships same business day from our warehouse when ordered before cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for Carrier model \u003cstrong\u003ePY1RJA048074AAWA\u003c\/strong\u003e packaged units. Related capacitor part numbers for this platform include \u003cstrong\u003eP291-4554RS\u003c\/strong\u003e (45+5 MFD 440V Dual Run), \u003cstrong\u003eP291-0403\u003c\/strong\u003e (Single Run Capacitor), and \u003cstrong\u003eP291-1503\u003c\/strong\u003e (Single Run Capacitor) — available separately. Always verify motor voltage, HP, and rotation on the unit data plate before ordering. Not sure this is the right part? Our HVAC parts specialists confirm fitment before you buy — in stock and ready to ship today.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640673587571,"sku":"CARRIE-PY1RJA048074AAWA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640673620339,"sku":"CARRIE-PY1RJA048074AAWA-CAPACITOR-HC30GB230-GEN","price":551.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-dual-HC30GB230_ed0b3d20-f158-4c4b-9d91-24b7a39201e9.jpg?v=1782914174"},{"product_id":"carrier-py1ppa042120acbs-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ Capacitor 4µF 370V — PY1PPA042120AC","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor (HC30GB230) for Model PY1PPA042120ACBS\u003c\/h1\u003e\u003cp\u003eThis is the OEM factory-specified draft inducer motor assembly for the \u003cstrong\u003eCarrier PY1PPA042120ACBS\u003c\/strong\u003e packaged unit. The draft inducer motor vents combustion gases safely out of the heat exchanger before and during each heating cycle. When this motor fails or degrades, the furnace section will typically lock out on a pressure switch fault — refusing to fire because the control board cannot confirm safe flue gas evacuation. Common symptoms include no-heat calls, a spinning inducer wheel that hums but doesn't pull enough static pressure, or a motor that runs briefly then trips on thermal overload.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V | 1-Phase | 3,450 RPM | CCWLE rotation | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mounting | Includes 4 µF \/ 370 VAC run capacitor and hall effect sensor for proving operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM assembly, not an aftermarket substitute. OEM motors are wound and balanced to exact factory tolerances, ensuring correct RPM, airflow, and hall effect signal integrity. Generic alternatives frequently deviate in RPM and capacitor µF rating, triggering recurring pressure switch faults and shortened motor life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Requires gas valve lockout and inducer housing disassembly. Tools needed: 5\/16\" nut driver, needle-nose pliers, multimeter, manometer (to verify pressure switch operation post-install). Photograph all wiring before disconnecting. Note rotational direction before removing the wheel from the old motor shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Direct OEM replacement for Carrier model \u003cstrong\u003ePY1PPA042120ACBS\u003c\/strong\u003e packaged units. Part number HC30GB230 has been superseded by HC30GR231 — both are cross-compatible OEM assemblies for this application. Verify shaft diameter, rotation (CCWLE), and voltage on your unit's data plate prior to ordering. Our HVAC parts team is available to confirm fitment before you buy.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640847454579,"sku":"CARRIE-PY1PPA042120ACBS-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640847487347,"sku":"CARRIE-PY1PPA042120ACBS-CAPACITOR-HC30GB230-GEN","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30GB230_e9339399-cc47-4b17-8437-8bfa0ad6bc8e.jpg?v=1782914183"},{"product_id":"carrier-py1ppa042100adba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ Cap 4 MFD 370V — PY1PPA042100ADBA","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor 4 MFD 370V for Model PY1PPA042100ADBA\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor with integrated capacitor (HC30GB230 \/ superseded by HC30GR231) is the factory-specified replacement for the \u003cstrong\u003eCarrier PY1PPA042100ADBA\u003c\/strong\u003e packaged gas unit. The draft inducer draws combustion gases through the heat exchanger and out the flue before and during the heating cycle. When this motor fails, the furnace control board cannot prove inducer operation, resulting in a pressure switch lockout, a no-heat condition, or repeated ignition failures. Common symptoms include the unit cycling off immediately after the call for heat, unusual motor noise, or a seized\/burnt-smelling blower wheel.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V | 1-Phase | 3450 RPM | CCWLE rotation | 5\/16\" x 3.3\" shaft | Ball bearing | Includes 4 MFD 370V run capacitor and hall effect sensor | Thru-bolt mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM assembly is manufactured to exact Carrier factory tolerances, ensuring correct airflow, proper pressure switch actuation, and certified hall effect sensor output. Generic motors frequently miss shaft length or rotation specs, causing improper flue sealing and nuisance pressure switch trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Requires shutting off gas and electrical supply before beginning. Tools needed: 1\/4\" and 5\/16\" nut drivers, flat-head screwdriver, multimeter, and duct tape or foil tape for flue resealing. Photograph all wiring and flue connections before removal. The hall effect sensor connector must be transferred to the new motor harness — do not overtighten clamp screws on the flue collar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered as the direct OEM replacement for \u003cstrong\u003eCarrier model PY1PPA042100ADBA\u003c\/strong\u003e. Also fits a wide range of Carrier, Bryant, and Payne packaged and split gas furnace applications that originally specified HC30GB230 or HC30GB231. Always verify motor HP, voltage, RPM, rotation direction, and shaft dimensions against your unit's data plate before ordering. Questions about fitment? Our HVAC parts specialists verify compatibility before you buy — contact us today and ship the same day.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640854794611,"sku":"CARRIE-PY1PPA042100ADBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640854827379,"sku":"CARRIE-PY1PPA042100ADBA-CAPACITOR-HC30GB230-GEN","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30GB230_e186c65e-0304-424f-b277-d39b9f989337.jpg?v=1782914178"},{"product_id":"carrier-py1ppa036100adba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ Cap 4 MFD 370V — PY1PPA036100ADBA","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor (HC30GB230 \/ HC30GR231) for Model PY1PPA036100ADBA\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor with capacitor is the factory-specified replacement for the \u003cstrong\u003eCarrier PY1PPA036100ADBA\u003c\/strong\u003e packaged unit. The draft inducer motor performs a critical safety function: it draws combustion air into the heat exchanger and expels exhaust gases safely out of the flue \u003cem\u003ebefore\u003c\/em\u003e the burners are allowed to fire. When this motor fails or its run capacitor degrades, the furnace control board will detect a missing inducer-proved signal, resulting in a hard lockout, no-heat condition, or repeated pressure switch fault codes.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V, 1-Phase | 3450 RPM | CCWLE rotation | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mounting | Includes 4 MFD 370 VAC run capacitor and hall-effect sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier Factory Authorized Part, manufactured to exact OEM tolerances. Generic inducer motors frequently ship with mismatched capacitor ratings and incorrect shaft dimensions, risking premature bearing failure and combustion safety issues — always specify OEM on draft inducers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Shut off gas and 24V control power before beginning. Tools required: 1\/4\" and 5\/16\" nut drivers, slip-joint pliers, multimeter, and high-temp gasket sealant. Photograph all wiring and flue connections before disassembly. Replace the inducer gasket at the same time to prevent exhaust leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered as a direct OEM replacement for Carrier model \u003cstrong\u003ePY1PPA036100ADBA\u003c\/strong\u003e packaged units. Note: HC30GB230 has been superseded by HC30GR231 — both part numbers are fulfilled by the current production unit shipped here. Verify motor HP, voltage, RPM, and rotation direction against your unit's data plate prior to ordering. Our HVAC parts specialists are available to confirm fitment before you purchase.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640873996659,"sku":"CARRIE-PY1PPA036100ADBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640874029427,"sku":"CARRIE-PY1PPA036100ADBA-CAPACITOR-HC30GB230-GEN","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30GB230_77b12714-be32-4de7-ab2f-7839b92d298d.jpg?v=1782914176"},{"product_id":"carrier-py1ppa036080acba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ Capacitor for PY1PPA036080ACBA","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor (HC30GB230) for Model PY1PPA036080ACBA\u003c\/h1\u003e\u003cp\u003eThe \u003cstrong\u003eCarrier HC30GB230\u003c\/strong\u003e is the factory OEM draft inducer motor with integrated run capacitor, engineered as a direct replacement for the \u003cstrong\u003eCarrier PY1PPA036080ACBA\u003c\/strong\u003e packaged unit. The draft inducer motor creates the negative pressure required to pull combustion gases through the heat exchanger and exhaust them safely out the flue. Without a functioning inducer motor, the pressure switch will not close, and the unit will lock out on a no-heat fault — leaving your system dead before ignition ever occurs.\u003c\/p\u003e\u003cp\u003eCommon failure symptoms that indicate a faulty draft inducer motor include: the unit attempting to start but locking out before ignition, a grinding or rattling noise from the inducer housing, a pressure switch fault code displayed on the control board, or a motor that hums but fails to spin. Replacing the entire motor-and-capacitor assembly with the OEM unit ensures exact airflow performance and pressure switch compatibility.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM Carrier Part # HC30GB230 | Draft inducer motor with run capacitor | Factory-matched RPM, voltage, and CFM for PY1PPA036080ACBA | Includes integrated capacitor for reliable single-wire hookup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM assembly. OEM motors are wound and balanced to exact factory tolerances, ensuring correct draft pressure for pressure switch closure. Aftermarket alternatives may vary in RPM and shaft diameter, risking recurring faults or pressure switch mis-trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Disconnect power and gas before beginning. Tools needed: nut driver set, Phillips screwdriver, needle-nose pliers, multimeter. Photograph all wiring and flue connections before removal. Note inducer housing gasket condition and replace if damaged. Always verify pressure switch hose connections after installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects in materials and workmanship. Ships same business day from our warehouse when ordered before 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the \u003cstrong\u003eCarrier PY1PPA036080ACBA\u003c\/strong\u003e packaged gas\/electric unit. Always verify the part number on your existing motor's label and cross-reference with your unit's data plate before ordering. Our fitment team is available to confirm compatibility — contact us before you order if you have any questions. In stock and ready to ship today.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640880681331,"sku":"CARRIE-PY1PPA036080ACBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640880746867,"sku":"CARRIE-PY1PPA036080ACBA-CAPACITOR-HC30GB230-GEN","price":115.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30GB230_505d77ea-b49a-4534-9ee7-f18fb5b907c3.jpg?v=1782914185"},{"product_id":"carrier-py1ppa036060adba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ Capacitor 4µF 370V — PY1PPA036060AD","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor (HC30GB230) for Model PY1PPA036060ADBA\u003c\/h1\u003e\u003cp\u003eThis is the OEM factory-specified draft inducer motor assembly for the \u003cstrong\u003eCarrier PY1PPA036060ADBA\u003c\/strong\u003e packaged unit. The draft inducer motor is the first component to activate in every heating cycle — it pressurizes the heat exchanger, proves combustion airflow via the pressure switch, and safely exhausts flue gases before the gas valve is allowed to open. When this motor fails or its run capacitor degrades, the furnace section will lock out on a pressure switch fault, often displaying a fault code before any heat is produced. The included \u003cstrong\u003e4 µF 370V run capacitor\u003c\/strong\u003e is pre-matched to the motor for correct starting torque and sustained run performance.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V, 1-Phase | 3450 RPM | CCW rotation (CCWLE) | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mounting | Includes hall effect sensor + 4 µF 370V run capacitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM assembly meets exact Carrier factory tolerances for airflow, RPM, and capacitor µF rating. Generic motors frequently deviate in rotation direction, shaft length, and capacitor sizing — causing pressure switch nuisance trips or premature motor failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Shut off power and gas supply before starting. Tools needed: nut driver set, flat-head screwdriver, needle-nose pliers, manometer (to re-verify pressure switch after replacement). Photograph all wiring and flue connections prior to disassembly. Note: HC30GB230 is superseded by HC30GR231 — both are fully compatible with PY1PPA036060ADBA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003ePY1PPA036060ADBA\u003c\/strong\u003e packaged unit gas\/electric section. Also used across many Carrier, Bryant, and Payne packaged and split-system gas furnace applications — verify your unit's data plate voltage (208\/230V) and confirm RPM before ordering. Cross-references include AO Smith JF1H102N and superseding OEM part HC30GR231. Questions about fitment? Our HVAC parts specialists verify compatibility before you order — \u003cstrong\u003ein stock and ships today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640887202163,"sku":"CARRIE-PY1PPA036060ADBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640887234931,"sku":"CARRIE-PY1PPA036060ADBA-CAPACITOR-HC30GB230-GEN","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30GB230_5473f98a-6d80-471b-b21c-9ea772db7fc8.jpg?v=1782914181"},{"product_id":"carrier-py1ppa030080acba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ 4 MFD Capacitor 1\/16 HP — PY1PPA030080ACB","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor (HC30GB230) for Model PY1PPA030080ACBA\u003c\/h1\u003e\u003cp\u003eThis is the OEM factory-specified draft inducer motor assembly for the \u003cstrong\u003eCarrier PY1PPA030080ACBA\u003c\/strong\u003e gas furnace. The draft inducer motor is the first component to energize on every heat call — it purges residual combustion gases from the heat exchanger, builds negative pressure to close the pressure switch, and proves safe venting before the ignition sequence begins. When this motor fails, you'll typically see one or more of the following: the furnace locks out before ignition, a pressure switch fault code is triggered, the inducer runs loudly with bearing noise, or the unit short-cycles with no heat output.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V | 60 Hz | 1-Phase | 3,450 RPM | CCWLE rotation | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mounting | Includes factory-matched 4 MFD @ 370 VAC run capacitor and hall effect sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier Factory Authorized Parts assembly manufactured to exact OEM tolerances. Generic inducers frequently deviate in rotation, shaft dimensions, or capacitor rating — any mismatch risks pressure switch failure, venting issues, or carbon monoxide hazards. OEM is the only safe choice here.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Shut off gas and power before beginning. Tools needed: 1\/4\" and 5\/16\" nut drivers, flat-head screwdriver, multimeter, and high-temp RTV silicone for the inducer gasket. Photograph all wiring and pressure switch tubing connections before removal. Verify rotation direction and confirm pressure switch operation after installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against manufacturing defects. Replacement recommended whenever hall effect sensor signals are erratic or bearing noise is present. Ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed as the direct OEM replacement for \u003cstrong\u003eCarrier model PY1PPA030080ACBA\u003c\/strong\u003e gas furnaces. Also cross-references Carrier HC30GR231 (current superseding part number), AO Smith JF1H102N, and Fasco 71626713. Always verify your unit's data plate voltage and motor specifications before ordering. Our parts specialists are available to confirm fitment — contact us before you order if you have any questions.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640893460851,"sku":"CARRIE-PY1PPA030080ACBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640893493619,"sku":"CARRIE-PY1PPA030080ACBA-CAPACITOR-HC30GB230-GEN","price":361.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-dual-HC30GB230_42fe4591-17bd-4e6b-81eb-971475634d18.jpg?v=1782914166"},{"product_id":"carrier-py1ppa030060adba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor 4MFD 370V for PY1PPA030060ADBA","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor — HC30GB230 (HC30GR231) for Model PY1PPA030060ADBA\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor with integrated capacitor is the factory-specified replacement for the \u003cstrong\u003eCarrier PY1PPA030060ADBA\u003c\/strong\u003e packaged gas unit. The inducer motor creates the negative pressure needed to pull combustion gases through the heat exchanger and exhaust them safely outdoors before and during the burner firing sequence. When this motor fails or degrades, the furnace section will lockout on a pressure switch fault, deliver no heat, or exhibit erratic ignition cycling — symptoms that are frequently misdiagnosed as a bad pressure switch or control board.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V, 1-Phase, 60 Hz | 3450 RPM | CCWLE rotation | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mount | Includes 4 MFD @ 370 VAC run capacitor and hall effect sensor for proving operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier Factory Authorized Part (OEM part HC30GB230, current shipping equivalent HC30GR231). OEM motors are wound and balanced to exact factory specifications, ensuring correct RPM, airflow proving, and pressure switch closure. Generic aftermarket motors frequently run off-speed, causing nuisance lockouts and premature heat exchanger stress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Requires disconnecting the flue transition, inducer housing, wiring harness, and hall effect sensor connector. Tools needed: 1\/4\" and 5\/16\" nut drivers, wire stripper, multimeter, and pliers. Always confirm the capacitor is discharged and power is off at the disconnect before handling. Photograph all wiring connections before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM manufacturer warranty. Ships same business day from our warehouse. Free shipping included.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for use in the \u003cstrong\u003eCarrier PY1PPA030060ADBA\u003c\/strong\u003e packaged gas\/electric unit. OEM part number HC30GB230 has been superseded by HC30GR231 — both numbers are fulfilled by the same current-production Carrier Factory Authorized Part. Verify HP, voltage, RPM, and rotation against your unit's motor data plate before ordering. Our fitment team is available to confirm compatibility before you buy.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640898539891,"sku":"CARRIE-PY1PPA030060ADBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640898572659,"sku":"CARRIE-PY1PPA030060ADBA-CAPACITOR-HC30GB230-GEN","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30GB230.jpg?v=1782914072"},{"product_id":"carrier-py1pna060120adba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor 4 MFD 370V 1\/16HP — PY1PNA060120ADBA","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor (HC30GB230 \/ HC30GR231) for Model PY1PNA060120ADBA\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor with integrated capacitor is the factory-specified replacement for the \u003cstrong\u003eCarrier PY1PNA060120ADBA\u003c\/strong\u003e packaged gas unit. The draft inducer motor creates the negative pressure required to pull combustion gases safely out of the heat exchanger and through the flue before ignition begins. When this motor fails, the furnace will lock out on a pressure switch fault — typically displaying a fault code — because the control board cannot confirm safe draft before allowing gas flow. A failed capacitor within the assembly is often the first sign of trouble, causing the motor to hum without spinning or run sluggishly at reduced RPM.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V, 1-Phase | 3450 RPM | CCWLE rotation | 5\/16\" × 3.3\" shaft | Ball bearing | Thru-bolt mounting | Includes 4 MFD 370V run capacitor and hall effect sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM assembly (HC30GB230, superseded by HC30GR231). OEM motors are wound and balanced to factory tolerances, ensuring the hall effect sensor signal matches the control board's exact proving requirements. Generic motors frequently trigger nuisance pressure switch lockouts due to marginal RPM performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Requires disconnecting flue tubing, pressure switch hose, and wiring harness. Tools needed: 1\/4\" and 5\/16\" nut drivers, flathead screwdriver, needle-nose pliers, multimeter. Always disconnect power at the breaker and confirm zero voltage before handling. Photograph all wiring connections before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty on parts and defects. Ships same business day from our warehouse when ordered before cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Direct OEM replacement for Carrier model \u003cstrong\u003ePY1PNA060120ADBA\u003c\/strong\u003e packaged gas units. Part number HC30GB230 has been superseded by HC30GR231 — both are fulfilled as the current revision. Verify voltage (208\/230V), HP (1\/16), and RPM (3450) against your unit's data plate before ordering. Our fitment team is available to confirm compatibility before you buy.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640913613171,"sku":"CARRIE-PY1PNA060120ADBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640913645939,"sku":"CARRIE-PY1PNA060120ADBA-CAPACITOR-HC30GB230-GEN","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-dual-HC30GB230_84d2864f-ec8d-47ec-acb8-c58e93b5e4ff.jpg?v=1782914069"},{"product_id":"carrier-py1pna048120aeba-capacitor-1ycipl","title":"OEM Carrier Draft Inducer Motor w\/ 4 MFD Capacitor 1\/16HP — HC30GB230","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor with Capacitor 1\/16HP 208\/230V 3450RPM for Model PY1PNA048120AEBA\u003c\/h1\u003e\u003cp\u003eThis OEM Carrier draft inducer motor assembly (part# \u003cstrong\u003eHC30GB230\u003c\/strong\u003e) is the factory-specified replacement for the \u003cstrong\u003eCarrier PY1PNA048120AEBA\u003c\/strong\u003e gas furnace. The draft inducer motor creates the negative pressure needed to pull combustion gases safely through the heat exchanger and out the flue before and during each heating cycle. When this motor fails, the furnace will typically lock out before ignition — the inducer will either fail to start, run intermittently, or trip the pressure switch due to insufficient airflow, resulting in a no-heat call. This complete assembly ships with the matched run capacitor and hall effect sensor, ensuring a drop-in OEM replacement with no guesswork.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/16 HP | 208\/230V | 3450 RPM | 1-Phase | Includes 4 µF 370V run capacitor and hall effect sensor | A.O. Smith model JF1H102N\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM assembly matched to factory tolerances. Generic inducer motors often differ in flange geometry, shaft length, or RPM calibration — causing pressure switch faults or premature bearing failure. OEM is the correct choice for this application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Disconnect power and gas before beginning. Tools needed: nut driver set, Phillips screwdriver, pipe sealant, multimeter. Disconnect the flue outlet, detach the motor wiring harness and capacitor leads (photograph before removal), unbolt the motor flange from the inducer housing, and reverse to install. Verify rotation direction before final reassembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. Ships same business day from our warehouse when ordered by 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for Carrier model \u003cstrong\u003ePY1PNA048120AEBA\u003c\/strong\u003e gas furnace. Note: HC30GB230 has been discontinued by the manufacturer — the current factory-authorized successor is HC30GR231, which is a direct drop-in replacement included in this listing. Verify your unit's data plate voltage (208\/230V) before ordering. Have questions about fitment? Our HVAC parts specialists verify compatibility before you buy — no guesswork, no returns.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640933437811,"sku":"CARRIE-PY1PNA048120AEBA-CAPACITOR-HC30GB230","price":410.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640933470579,"sku":"CARRIE-PY1PNA048120AEBA-CAPACITOR-HC30GB230-GEN","price":361.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-dual-HC30GB230_bccc73df-2987-4c49-a8ee-a0152347d1bd.jpg?v=1782914169"},{"product_id":"carrier-pg8maa048090agja-pressure-switch-jesotu","title":"OEM Carrier Draft Inducer Pressure Switch for PG8MAA048090AGJA","description":"\u003cdiv class=\"product-content\"\u003e\n\u003ch1\u003eOEM Carrier Draft Inducer Pressure Switch for PG8MAA048090AGJA\u003c\/h1\u003e\n\u003cp\u003eThe pressure switch is a critical safety device in your Carrier PG8MAA048090AGJA furnace. It confirms that the draft inducer motor is actually moving combustion air and venting flue gases before the control board allows the igniter and gas valve to fire. It senses negative pressure through a small rubber hose tapped into the inducer housing. When it fails — a stuck-open contact, a weak diaphragm, or a clogged port, hose, flue, or condensate drain — the inducer will run but the furnace won't light, it short-cycles, and the diagnostic LED typically flashes the code for \"pressure switch did not close.\" A switch stuck closed is just as dangerous, since it lets the furnace run without proving draft.\n\nSpecs: This is a normally-open single-pole switch with a single sensing port, rated to actuate at a specific negative pressure measured in inches of water column (typically in the -0.40\" to -0.70\" WC range for this furnace). The set point is printed on the switch body and must match your furnace's design value exactly.\n\nWhy OEM matters: A wrong set-point switch defeats the protection it exists to provide. Too sensitive and it nuisance-trips on windy days; too loose and it allows ignition even with a partially blocked flue — a carbon monoxide risk. This OEM switch is calibrated to the exact WC threshold the PG8MAA was certified with.\n\nInstallation: Difficulty 2 of 5. Tools: 1\/4\" nut driver, and a manometer if you want to verify draft. SAFETY: turn off power, and always inspect and clear the hose and inducer port — a clogged hose mimics a failed switch. Never jumper or bypass a pressure switch.\n\nShips same business day from our stocked warehouse on orders placed before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.\u003c\/p\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis part is compatible with Carrier model PG8MAA048090AGJA. Always verify the part number against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose OEM?\u003c\/h2\u003e\n\u003cp\u003eOEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.\u003c\/p\u003e\n\u003ch2\u003eShipping \u0026amp; Returns\u003c\/h2\u003e\n\u003cp\u003eSame-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62642961121651,"sku":"CARRIE-PG8MAA048090AGJA-PRESSURE_SWITCH-HK02LB008","price":27.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62642961154419,"sku":"CARRIE-PG8MAA048090AGJA-PRESSURE_SWITCH-HK02LB008-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK02LB008_04db4e99-a5eb-4268-92a1-c5fe5e9e0fb0.jpg?v=1782914198"},{"product_id":"carrier-pg8jea048070aaja-pressure-switch-h43srw","title":"OEM Carrier Draft Inducer Pressure Switch for PG8JEA048070AAJA","description":"\u003cdiv class=\"product-content\"\u003e\n\u003ch1\u003eOEM Carrier Draft Inducer Pressure Switch for PG8JEA048070AAJA\u003c\/h1\u003e\n\u003cp\u003eThe pressure switch is the safety device that proves proper venting before your Carrier PG8JEA048070AAJA is allowed to ignite. When the draft inducer motor starts, it creates negative pressure that closes this switch, telling the control board the flue is clear and combustion air is moving. If the switch doesn't close — or opens during the cycle — the board halts ignition to prevent flue gases from spilling. Symptoms of a failed switch include the inducer running continuously with no ignition, the furnace locking out, repeated short-cycling, or error codes pointing to a pressure or venting fault. A stuck-open switch is a common no-heat cause; a stuck-closed switch is a dangerous fault that bypasses a critical safety check.\n\nThis OEM switch is calibrated to a specific trip point measured in inches of water column (\"WC), matched to your furnace's inducer and venting design. The setpoint and the normally-open contact configuration are model-specific — that calibration is exactly what makes it a safety device.\n\nOEM matters because pressure switch trip points are not interchangeable. A generic switch with the wrong \"WC setpoint will either nuisance-trip on a healthy system or, worse, fail to open when venting is actually blocked, defeating the safety function. Aftermarket switches also tend to use lower-grade diaphragms and contacts that drift out of calibration over time. The OEM unit holds Carrier's exact specification.\n\nInstall difficulty: 2 of 5. Tools: 1\/4\" nut driver and needle-nose pliers; a manometer is ideal to verify the trip point after install. SAFETY: turn off power at the breaker and shut the gas off before servicing, and reconnect the rubber pressure tubing fully — a loose hose mimics a failed switch.\n\nShips same business day from our stocked warehouse on orders before 3 PM CST. Backed by a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.\u003c\/p\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis part is compatible with Carrier model PG8JEA048070AAJA. Always verify the part number against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose OEM?\u003c\/h2\u003e\n\u003cp\u003eOEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.\u003c\/p\u003e\n\u003ch2\u003eShipping \u0026amp; Returns\u003c\/h2\u003e\n\u003cp\u003eSame-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62643098386803,"sku":"CARRIE-PG8JEA048070AAJA-PRESSURE_SWITCH-HK06WC091","price":27.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62643098419571,"sku":"CARRIE-PG8JEA048070AAJA-PRESSURE_SWITCH-HK06WC091-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK06WC091.jpg?v=1782914195"},{"product_id":"carrier-pg8jea024045abja-pressure-switch-jesotu","title":"OEM Carrier Draft Inducer Pressure Switch for PG8JEA024045ABJA","description":"\u003cdiv class=\"product-content\"\u003e\n\u003ch1\u003eOEM Carrier Draft Inducer Pressure Switch for PG8JEA024045ABJA\u003c\/h1\u003e\n\u003cp\u003eThe pressure switch verifies that your Carrier PG8JEA024045ABJA is venting properly before the burners are allowed to fire. When the draft inducer spins up, it pulls a negative pressure that closes this switch, confirming to the control board that flue gases have a clear path out and combustion air is flowing. If the switch fails to close — or opens mid-cycle — the board blocks ignition to keep flue products from spilling indoors. You'll typically see the inducer running with no ignition, the furnace locking out, persistent short-cycling, or a control-board fault code referencing pressure or venting. A switch stuck open causes no-heat; one stuck closed defeats a vital safety interlock.\n\nThis OEM switch is calibrated to a precise trip point in inches of water column (\"WC) and a normally-open contact arrangement matched to your inducer and vent configuration. That model-specific setpoint is what allows it to function as a true safety device.\n\nOEM fitment is essential because pressure-switch setpoints are not generic. A switch with the wrong \"WC rating will nuisance-trip on a perfectly healthy furnace or, far more dangerously, fail to open when the flue is actually obstructed — eliminating the protection it exists to provide. Aftermarket units also tend to use lower-grade diaphragms and contacts that drift out of calibration. The OEM part holds Carrier's exact specification for the life of the switch.\n\nInstall difficulty: 2 of 5. Tools: 1\/4\" nut driver and needle-nose pliers, with a manometer recommended to confirm the trip point. SAFETY: turn off power at the breaker and shut off the gas before servicing, and seat the rubber pressure hose fully — a cracked or loose tube mimics a bad switch.\n\nShips same business day from our stocked warehouse on orders before 3 PM CST. Includes a 1-year OEM warranty and 30-day hassle-free returns on uninstalled parts.\u003c\/p\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis part is compatible with Carrier model PG8JEA024045ABJA. Always verify the part number against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose OEM?\u003c\/h2\u003e\n\u003cp\u003eOEM parts are manufactured to the exact factory specifications for your unit. Generic aftermarket alternatives may fit physically but often use lower-rated components that reduce equipment life and void manufacturer warranties. When the cost difference between OEM and generic is $10-30, the OEM part is always the smarter investment on a system worth $5,000-$15,000.\u003c\/p\u003e\n\u003ch2\u003eShipping \u0026amp; Returns\u003c\/h2\u003e\n\u003cp\u003eSame-day shipping on orders before 3 PM CST. Standard delivery 2-5 business days, express options available at checkout. 30-day hassle-free returns on uninstalled parts — free return shipping included. 1-year OEM factory warranty coverage.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62643098648947,"sku":"CARRIE-PG8JEA024045ABJA-PRESSURE_SWITCH-HK02LB008","price":27.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62643098681715,"sku":"CARRIE-PG8JEA024045ABJA-PRESSURE_SWITCH-HK02LB008-GEN","price":19.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HK02LB008.jpg?v=1782914193"},{"product_id":"carrier-n6d48ng482026-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6D48NG482026 — 50HE4007","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6D48NG482026 — Part# 50HE400792\u003c\/h1\u003e\u003cp\u003eThis OEM capacitor is the factory-specified run capacitor included in the \u003cstrong\u003eDraft Inducer Motor Assembly (Part# 50HE400792)\u003c\/strong\u003e for the \u003cstrong\u003eCarrier N6D48NG482026\u003c\/strong\u003e packaged gas unit. The draft inducer motor capacitor provides the starting torque and sustained run current needed to spin the inducer blower, which proves combustion airflow before ignition begins. When this capacitor fails, the inducer motor may hum without spinning, run sluggishly, or fail to reach the RPM necessary to close the pressure switch — resulting in a no-heat lockout condition before the burners ever fire.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched MFD rating and voltage | Round or oval case (factory spec) | Designed for Carrier draft inducer motor assembly 50HE400792 | Tight ±5% tolerance for reliable inducer startup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is the factory OEM capacitor matched to Carrier's inducer motor specifications. Generic capacitors with wider MFD tolerances can cause the inducer to underperform, leading to nuisance pressure switch trips, hard starts, and premature motor bearing failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Shut off power and gas before servicing. Discharge the capacitor before handling terminals. Tools needed: flathead and Phillips screwdrivers, 1\/4\" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before disconnecting. Typically located on or near the inducer motor housing in the vestibule panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered as a direct OEM replacement for the \u003cstrong\u003eCarrier N6D48NG482026\u003c\/strong\u003e packaged gas unit using draft inducer motor assembly part number \u003cstrong\u003e50HE400792\u003c\/strong\u003e. Verify the existing capacitor's MFD and voltage ratings against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — order with confidence and get free same-day shipping on all in-stock parts.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909263544691,"sku":"CARRIE-N6D48NG482026-CAPACITOR-50HE400792","price":1200.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909263577459,"sku":"CARRIE-N6D48NG482026-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-50HE400792-1-1784664065759.jpg?v=1784664067"},{"product_id":"carrier-n6d48ng482024-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6D48NG482024","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6D48NG482024\u003c\/h1\u003e\u003cp\u003eThis OEM capacitor is the factory-specified run capacitor included with the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6D48NG482024\u003c\/strong\u003e packaged gas unit. The inducer motor capacitor provides the phase-shift current necessary to start and sustain the draft inducer blower, which must prove combustion airflow before ignition is ever attempted. When this capacitor weakens or fails, the inducer motor hums but fails to spin, the pressure switch never closes, and the furnace locks out before reaching ignition — leaving you with no heat and a blinking fault code.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for the Carrier N6D48NG482024 draft inducer motor assembly | Round or oval case depending on production run | Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e | Meets factory ±5% tolerance for reliable motor starting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is engineered to the exact electrical specifications of the Carrier inducer motor. Generic capacitors frequently run outside tolerance, causing slow motor starts, overheating, and premature inducer motor failure — a far more expensive repair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Turn off power at the disconnect and discharge the capacitor before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter with capacitance setting. Photograph all wiring connections before removal. The capacitor is typically bracket-mounted adjacent to or on the inducer motor housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003eN6D48NG482024\u003c\/strong\u003e packaged gas unit draft inducer motor assembly. Cross-references OEM part numbers 50HE400792 and HC30CL461. Always verify the MFD and voltage rating printed on your existing capacitor against the data plate before ordering — inducer motor capacitor values vary by production run and motor manufacturer. Our fitment team is available to confirm compatibility before you buy.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909264396659,"sku":"CARRIE-N6D48NG482024-CAPACITOR-50HE400792","price":350.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909264429427,"sku":"CARRIE-N6D48NG482024-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-motor-HC30GB230-1-1784933356160.jpg?v=1784933357"},{"product_id":"carrier-n6a48ng482019-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG482019","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG482019\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor capacitor is the factory-specified replacement for the \u003cstrong\u003eCarrier N6A48NG482019\u003c\/strong\u003e packaged gas\/electric unit. The inducer motor capacitor provides the starting and running torque required by the draft inducer motor, which purges combustion gases before and during each heating cycle. When this capacitor fails, the inducer motor will hum without spinning, stall under load, or fail to reach operating speed — causing the pressure switch to never close and locking out the furnace before ignition ever occurs. Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD rating and 370V\/440V rating as specified for Carrier N6A48NG482019 | Round or oval case per OEM design | ±3% tolerance for precise motor performance and longevity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor meets exact Carrier factory tolerances. Generic alternatives typically run ±10% MFD deviation, which causes inducer motor overheating, premature bearing wear, and repeated pressure switch nuisance trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter (capacitance mode to verify). Photograph all wiring connections before disconnecting. Always shut off power at the disconnect and breaker before beginning work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for the \u003cstrong\u003eCarrier N6A48NG482019\u003c\/strong\u003e packaged unit draft inducer motor assembly. Cross-references OEM part numbers 50HE400792 and HC30CL461. Verify the capacitor's MFD and voltage rating against your unit's data plate and existing component label before ordering. Not sure if this is the right part? Our HVAC parts specialists verify fitment before you buy — contact us before placing your order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909270327667,"sku":"CARRIE-N6A48NG482019-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909270360435,"sku":"CARRIE-N6A48NG482019-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_35b5049f-0da5-4b8c-87fe-04e9bd9cc26e.jpg?v=1782914157"},{"product_id":"carrier-n6a48ng482017-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG482017","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG482017\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor capacitor is the factory-specified replacement component for the \u003cstrong\u003eCarrier N6A48NG482017\u003c\/strong\u003e packaged gas\/electric unit. The inducer motor capacitor provides the starting and running torque required to spin the draft inducer blower, which evacuates combustion gases and proves negative pressure to the pressure switch before ignition is attempted. When this capacitor fails, the inducer motor will hum without spinning, run sluggishly, or trip on thermal overload — causing a pressure switch fault, a no-heat lockout condition, or repeated ignition failure cycles. This part corresponds to OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor) and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor w\/ Capacitor).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for the Carrier N6A48NG482017 draft inducer motor | Round or oval case depending on assembly revision | ±3% MFD tolerance to ensure proper motor torque and long service life\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor meets Carrier's exact factory tolerance specifications. Aftermarket capacitors often carry a ±10% MFD variance, which shortens inducer motor bearing life, causes nuisance pressure switch trips, and can void equipment warranties.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Shut off gas and electrical power before beginning. Discharge the capacitor before touching terminals. Tools needed: flathead and Phillips screwdrivers, 1\/4\" nut driver, needle-nose pliers, and a multimeter to verify capacitance. Always photograph all wiring connections before disconnecting. Capacitor is typically located on or near the inducer motor housing in the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003eN6A48NG482017\u003c\/strong\u003e packaged unit. Cross-references OEM part numbers 50HE400792 and HC30CL461. Verify your existing capacitor's MFD and voltage rating against your unit's data plate and inducer motor nameplate before ordering. If you need fitment confirmation, our HVAC parts specialists are available to verify compatibility before you buy — same-day shipping available on in-stock orders.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909270524275,"sku":"CARRIE-N6A48NG482017-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909270557043,"sku":"CARRIE-N6A48NG482017-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_578ec265-473f-44b3-b734-fbd775d489e0.jpg?v=1782914155"},{"product_id":"carrier-n6a48ng482012-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG482012","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG482012\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor capacitor is the factory-specified replacement component for the \u003cstrong\u003eCarrier N6A48NG482012\u003c\/strong\u003e packaged gas\/electric unit. The inducer motor capacitor provides the starting and running torque required by the draft inducer blower, which must prove combustion airflow before the ignition sequence begins. When this capacitor fails, the inducer motor may hum without spinning, run sluggishly, or fail to start entirely — triggering a pressure switch lockout and a no-heat condition. This part corresponds to OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor) and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor w\/ Capacitor).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier N6A48NG482012 inducer motor | Round or oval case depending on production run | OEM ±3% tolerance for reliable motor performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are wound to exact factory specifications, ensuring proper inducer RPM and pressure switch proving. Generic alternatives often run outside ±10% MFD tolerance, which can cause nuisance pressure switch lockouts or premature motor bearing failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Always disconnect power and discharge the capacitor before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter with capacitance function. Photograph all wiring connections before removal. The inducer housing may require partial disassembly to access the capacitor bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders received by 3 PM local time ship same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003eN6A48NG482012\u003c\/strong\u003e packaged unit. Cross-references OEM part numbers 50HE400792 and HC30CL461. Always verify the MFD and voltage rating printed on your existing capacitor against this listing before ordering — inducer motor capacitor specs can vary by production date. Our fitment team is available to confirm compatibility before you purchase.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909272293747,"sku":"CARRIE-N6A48NG482012-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909272326515,"sku":"CARRIE-N6A48NG482012-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_e93e47dd-a86a-4f96-bd00-dc08d5c4b405.jpg?v=1782914153"},{"product_id":"carrier-n6a48ng482011-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG482011","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG482011\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM draft inducer motor capacitor for the \u003cstrong\u003eCarrier N6A48NG482011\u003c\/strong\u003e gas furnace. The inducer motor capacitor provides the starting and running capacitance needed to spin the draft inducer blower — the component responsible for purging combustion gases before and during each heating cycle. When this capacitor fails, the inducer motor may hum without spinning, run sluggishly, or fail to start entirely, triggering a pressure switch lockout and a complete no-heat condition. Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier N6A48NG482011 draft inducer motor assembly | Designed to OEM tolerance specifications | Cylindrical run capacitor form factor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is wound and rated to exact factory specifications, ensuring correct inducer motor RPM and torque. Generic capacitors with loose MFD tolerances (±10% or worse) can cause sluggish inducer performance, nuisance pressure switch trips, and premature motor bearing failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Disconnect power and confirm capacitor is fully discharged before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter with capacitance setting. Photograph all wiring connections before removal. The inducer assembly is typically located in the upper cabinet near the flue collar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed by cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered specifically for the Carrier \u003cstrong\u003eN6A48NG482011\u003c\/strong\u003e gas furnace draft inducer motor assembly. Verify your existing capacitor's MFD and voltage rating against your unit's data plate or wiring diagram before ordering. Cross-references OEM part numbers 50HE400792 and HC30CL461. Need help confirming fitment? Our HVAC parts specialists verify compatibility before you order — no guesswork, no returns.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909273276787,"sku":"CARRIE-N6A48NG482011-CAPACITOR-50HE400792","price":15.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909273309555,"sku":"CARRIE-N6A48NG482011-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-P291-0504-1-1785513189979.jpg?v=1785513191"},{"product_id":"carrier-n6a48ng481882-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481882","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481882\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM draft inducer motor capacitor for the \u003cstrong\u003eCarrier N6A48NG481882\u003c\/strong\u003e gas furnace. The draft inducer motor capacitor provides the starting and running torque required by the inducer blower motor, which exhausts combustion gases before and during each heating cycle. When this capacitor fails, the inducer motor may hum without spinning, run sluggishly, or fail to start entirely — triggering a pressure switch fault and locking out ignition. Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Matched to Carrier draft inducer motor assembly | Factory-rated voltage and MFD tolerance | Designed for continuous-duty inducer motor application | Verify MFD and voltage against your unit's data plate before ordering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor meets exact Carrier factory tolerances (±3% MFD). Off-brand substitutes often exceed ±10% tolerance, causing premature inducer motor wear, reduced airflow, and repeated pressure switch nuisance trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Recommended tools: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter with capacitance mode. Always photograph all wiring connections before disconnecting. Inducer assembly may require partial disassembly of the flue transition for access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered specifically for the Carrier \u003cstrong\u003eN6A48NG481882\u003c\/strong\u003e gas furnace draft inducer motor assembly. This capacitor is referenced under OEM part numbers 50HE400792 and HC30CL461. Confirm your existing capacitor's MFD and voltage rating on the data plate before ordering to ensure a correct match. Not sure if this fits your unit? Contact our fitment team — we verify compatibility before you buy so you never receive the wrong part.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909273407859,"sku":"CARRIE-N6A48NG481882-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909273440627,"sku":"CARRIE-N6A48NG481882-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_3c48de16-3937-4f8c-a2e6-3046c07e9d30.jpg?v=1782914148"},{"product_id":"carrier-n6a48ng481822-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481822","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481822\u003c\/h1\u003e\u003cp\u003eThis OEM capacitor is the factory-specified replacement component for the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6A48NG481822\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the electrical start and run boost the inducer blower motor needs to reach operating speed and maintain consistent airflow through the heat exchanger. When this capacitor fails, the inducer motor may hum without spinning, run erratically, or fail to start entirely — triggering a pressure switch fault and locking out the furnace before ignition is ever attempted. Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier N6A48NG481822 inducer motor assembly | Meets OEM tolerance standards | Direct drop-in replacement for capacitor included in 50HE400792 \/ HC30CL461 assemblies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine OEM Carrier capacitor engineered to exact factory tolerances. Generic capacitors with loose ±10% MFD tolerance can cause inducer motor strain, premature bearing wear, and repeated pressure switch nuisance trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge capacitor fully before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter. Always photograph existing wiring before disconnecting terminals. Turn off power at breaker and gas supply before servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for the \u003cstrong\u003eCarrier N6A48NG481822\u003c\/strong\u003e furnace draft inducer motor assembly. Cross-references OEM part numbers 50HE400792 and HC30CL461. Always verify your unit's data plate and existing capacitor markings (MFD and voltage) before ordering to ensure a precise fit. Not sure? Our HVAC parts specialists confirm fitment before you buy — reach out before placing your order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909274587507,"sku":"CARRIE-N6A48NG481822-CAPACITOR-50HE400792","price":12.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909274620275,"sku":"CARRIE-N6A48NG481822-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-P291-0504-1-1786216879094.jpg?v=1786216880"},{"product_id":"carrier-n6a48ng481815-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481815","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481815\u003c\/h1\u003e\u003cp\u003eThis OEM capacitor is the factory-specified run capacitor included with the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6A48NG481815\u003c\/strong\u003e packaged gas unit. The draft inducer motor capacitor provides the phase-shifted electrical charge required to start and sustain the inducer blower, which must prove combustion airflow before ignition is allowed. When this capacitor degrades or fails, the inducer motor will hum without spinning, spin slowly, or fail to reach operating speed — causing the pressure switch to fault and locking out the entire heating sequence. The result is a no-heat call with an inducer-related fault code on the control board.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Run capacitor matched to Carrier draft inducer motor assembly | Factory-rated MFD and voltage tolerance ±3% | Round or oval case per OEM spec | Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are manufactured to exact factory MFD tolerances, ensuring the inducer motor reaches proper RPM for reliable pressure switch closure. Generic capacitors rated ±10% tolerance can cause nuisance pressure switch faults, intermittent lockouts, and accelerated motor winding failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Recommended tools: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter with capacitance function. Always photograph existing wiring before disconnecting. Inducer assembly is typically accessed from the burner compartment panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for use with the draft inducer motor assembly on Carrier model \u003cstrong\u003eN6A48NG481815\u003c\/strong\u003e packaged gas heating\/cooling units. Verify existing capacitor MFD and voltage ratings on the inducer motor data label before ordering to confirm exact match. Not sure if this fits your unit? Our HVAC parts specialists verify fitment before you order — contact us and we'll confirm compatibility fast. \u003cstrong\u003eIn stock and ships today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909275636083,"sku":"CARRIE-N6A48NG481815-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909275668851,"sku":"CARRIE-N6A48NG481815-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_aa717cd4-9cd0-4598-8ede-50e0a0873234.jpg?v=1782914141"},{"product_id":"carrier-n6a48ng481814-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481814","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481814\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor for the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6A48NG481814\u003c\/strong\u003e packaged gas\/electric unit. The draft inducer motor capacitor provides the starting and running torque required to spin the inducer blower, which evacuates combustion gases and proves airflow before ignition begins. When this capacitor fails, the inducer motor will hum without spinning, run sluggishly, or draw excess current — triggering a pressure switch fault and preventing the furnace from ever reaching the ignition stage. Cross-references OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD rating for Carrier N6A48NG481814 inducer motor | 370V or 440V rated (verify on motor data plate) | Designed for continuous duty inducer motor use | Meets OEM ±5% capacitance tolerance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is wound to Carrier's exact factory specification. Aftermarket capacitors often ship with loose ±10% tolerances that cause inducer motor overheating, premature bearing wear, and repeat failures — especially on draft inducer assemblies that run at sustained high temperatures near the heat exchanger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling. Tools needed: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter (capacitance mode to verify before install). Always photograph the original wiring orientation before disconnecting terminals. The capacitor is typically mounted directly on or adjacent to the inducer motor housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; Shipping:\u003c\/strong\u003e Backed by a 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for the \u003cstrong\u003eCarrier N6A48NG481814\u003c\/strong\u003e packaged unit draft inducer motor assembly. Confirm your existing capacitor's MFD and voltage ratings on the motor data plate or original capacitor label before ordering. Cross-references OEM part numbers 50HE400792 and HC30CL461. Not sure it fits? Our HVAC parts team will verify compatibility before you place your order — just reach out.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909275799923,"sku":"CARRIE-N6A48NG481814-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909275832691,"sku":"CARRIE-N6A48NG481814-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_78d9b9a2-e908-4e6c-8e17-a28e48967e1f.jpg?v=1782914139"},{"product_id":"carrier-n6a48ng481460-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481460","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481460\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor capacitor is the factory-specified replacement for the \u003cstrong\u003eCarrier N6A48NG481460\u003c\/strong\u003e packaged gas\/electric unit. The inducer motor capacitor provides the starting and running torque required by the draft inducer motor to prove combustion airflow before ignition begins. When this capacitor degrades or fails, the inducer motor will hum without spinning, run sluggishly, or fail to reach operating speed — causing the pressure switch to remain open and locking out the furnace or heating section before any ignition attempt is made. Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating per Carrier specification | Designed for draft inducer motor run circuit | Round or oval case (verify against your data plate) | ±5% tolerance to maintain consistent inducer RPM and pressure switch activation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor meets Carrier's exact electrical tolerances. Off-brand substitutes frequently fall outside acceptable MFD range, causing premature inducer motor bearing wear and nuisance pressure switch lockouts — especially in cold-start conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Tools needed: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter (capacitance setting). Always photograph existing wiring and terminal orientation before disconnecting leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before 3 PM EST ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for the Carrier \u003cstrong\u003eN6A48NG481460\u003c\/strong\u003e packaged unit heating section. Always verify the MFD and voltage rating printed on your existing capacitor or the unit's wiring diagram before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you order if you have any questions.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909277077875,"sku":"CARRIE-N6A48NG481460-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909277110643,"sku":"CARRIE-N6A48NG481460-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_90ffc0f4-994f-4238-90d7-29e6320cab84.jpg?v=1782914134"},{"product_id":"carrier-n6a48ng481459-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481459","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481459\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor capacitor is the factory-specified replacement component for the \u003cstrong\u003eCarrier N6A48NG481459\u003c\/strong\u003e gas furnace. The inducer motor capacitor provides the starting and running boost charge required to spin the draft inducer blower, which purges combustion gases before and during each heating cycle. When this capacitor fails, the inducer motor may hum without spinning, run sluggishly, or fail to start entirely — triggering a pressure switch fault and locking out the furnace before ignition is ever attempted. Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier N6A48NG481459 draft inducer motor assembly | Compatible with 50HE400792 and HC30CL461 inducer assemblies | Round or oval case depending on assembly revision | Rated for continuous duty in high-temperature flue environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor meets exact factory MFD tolerance (±3%), ensuring reliable inducer startup and preventing premature motor winding burnout. Generic capacitors rated ±10% MFD can cause intermittent faults, nuisance lockouts, and shortened inducer motor life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter (capacitance mode). Always photograph existing wiring and capacitor orientation before disconnecting. Turn off power at the breaker and gas supply before beginning work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003eN6A48NG481459\u003c\/strong\u003e gas furnace draft inducer motor assembly. Verify your existing capacitor's MFD and voltage rating against your unit's data plate and inducer assembly label before ordering. This part is associated with inducer assembly part numbers 50HE400792 and HC30CL461. Not sure it fits? Our HVAC parts specialists verify fitment before you order — contact us with your model and serial number.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909277143411,"sku":"CARRIE-N6A48NG481459-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909277176179,"sku":"CARRIE-N6A48NG481459-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_79b877e0-ef47-4479-b6c3-4161a7a433fd.jpg?v=1782914131"},{"product_id":"carrier-n6a48ng481458-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481458","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481458\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor capacitor is the factory-specified replacement component for the \u003cstrong\u003eCarrier N6A48NG481458\u003c\/strong\u003e packaged gas\/electric unit. The inducer motor capacitor provides the start and run electrical charge required to spin the draft inducer blower, which evacuates combustion gases and proves negative pressure before ignition begins. When this capacitor fails, the inducer motor will hum without spinning, run sluggishly, or fail to reach operating speed — triggering the pressure switch and putting the unit into a no-heat lockout condition. Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier N6A48NG481458 inducer motor assembly | Designed for continuous-duty draft inducer application | Matches original case style and terminal configuration for direct drop-in fit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor meets Carrier's exact tolerance specifications (±3% MFD), ensuring the inducer motor reaches proper RPM for consistent pressure switch closure. Aftermarket capacitors with ±10% tolerance can cause intermittent pressure switch faults and premature motor bearing failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Discharge the old capacitor fully before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter with capacitance function. Always photograph existing wiring orientation before disconnecting terminals. Inducer assembly may require partial disassembly of the heat exchanger access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before 3 PM ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered specifically for the Carrier \u003cstrong\u003eN6A48NG481458\u003c\/strong\u003e packaged unit draft inducer motor assembly. Verify your existing capacitor's MFD and voltage rating against your unit's data plate before ordering. Cross-references OEM part numbers 50HE400792 and HC30CL461. Our fitment team is available to confirm compatibility before you order — no guesswork required.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909278486899,"sku":"CARRIE-N6A48NG481458-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909278519667,"sku":"CARRIE-N6A48NG481458-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_8953c19a-975e-4df3-8179-fd9b2a914433.jpg?v=1782914129"},{"product_id":"carrier-n6a48ng481457-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481457","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481457\u003c\/h1\u003e\u003cp\u003eThis is the OEM-specified run capacitor for the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6A48NG481457\u003c\/strong\u003e gas furnace. The draft inducer motor capacitor provides the precise starting torque and continuous run support required to spin the inducer blower — the component that purges combustion gases before and during each heating cycle. When this capacitor fails, the inducer motor will hum without spinning, run sluggishly, or fail to prove sufficient negative pressure to close the pressure switch, resulting in a no-heat lockout condition. Referenced under OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor) and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor w\/ Capacitor), this capacitor is the factory-matched replacement to restore full inducer performance without replacing the entire motor assembly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched MFD and voltage rating | Factory tolerance ±3% | Designed for inducer motor run-circuit duty | Replaces capacitor component within assemblies 50HE400792 and HC30CL461\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are wound to exact factory MFD tolerances, protecting the inducer motor bearings and windings from the stress of under- or over-capacitance. Generic alternatives often run ±10% tolerance, which can shorten inducer motor life and cause nuisance pressure switch faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Disconnect power and verify zero voltage before handling. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always photograph existing wiring and terminal connections before removal. Discharge any residual voltage from the old capacitor prior to disconnecting leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects in materials and workmanship. Orders placed before cutoff ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the \u003cstrong\u003eCarrier N6A48NG481457\u003c\/strong\u003e gas furnace draft inducer motor circuit. Verify your existing capacitor's MFD and voltage ratings against your unit's data plate and inducer motor nameplate before ordering. Cross-references OEM part numbers 50HE400792 and HC30CL461. Have your model and serial number ready — our fitment team is available to confirm compatibility before you order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909278585203,"sku":"CARRIE-N6A48NG481457-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909278617971,"sku":"CARRIE-N6A48NG481457-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_a8f50b71-a89e-4ecf-9ab4-8459ba7147b3.jpg?v=1782914127"},{"product_id":"carrier-n6a48ng481456-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG481456","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG481456\u003c\/h1\u003e\u003cp\u003eThis is the factory OEM capacitor matched to the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6A48NG481456\u003c\/strong\u003e gas furnace. The inducer motor capacitor provides the starting and running electrical charge that spins the draft inducer blower — the component responsible for purging combustion gases before and during each heating cycle. When this capacitor weakens or fails, the inducer motor may hum without spinning, run erratically, or fail to start entirely, triggering a pressure switch fault and locking the furnace out on a no-heat call. Cross-references OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor) and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor w\/ Capacitor).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier N6A48NG481456 inducer motor | Designed to OEM ±3% tolerance | Replaces capacitor component within assemblies 50HE400792 and HC30CL461\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors maintain exact MFD tolerance critical for inducer motor longevity. Off-brand substitutes with ±10% tolerance can cause motor overheating, premature bearing wear, and repeated pressure switch nuisance trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Always disconnect power and verify capacitor is fully discharged before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter with capacitance setting. Photograph all wiring connections before removal. Inducer motor access typically requires removing the furnace front panels and flue box cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed by 3 PM EST ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for the Carrier \u003cstrong\u003eN6A48NG481456\u003c\/strong\u003e gas furnace draft inducer motor. Always verify your existing capacitor's MFD and voltage ratings against your unit's data plate before ordering. If you are unsure whether this capacitor or the full inducer motor assembly (50HE400792 \/ HC30CL461) is needed, our HVAC parts specialists can confirm fitment before you buy — contact us before placing your order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909278716275,"sku":"CARRIE-N6A48NG481456-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909278749043,"sku":"CARRIE-N6A48NG481456-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_38c9b110-4e0c-427b-a3b1-000a4b663065.jpg?v=1782914122"},{"product_id":"carrier-n6a48ng480198-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG480198","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG480198\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor run capacitor is the factory-specified replacement component for the \u003cstrong\u003eCarrier N6A48NG480198\u003c\/strong\u003e packaged gas unit. The inducer motor capacitor provides the start and run electrical boost needed to spin the draft inducer blower at proper speed. The inducer motor must reach full RPM before the pressure switch closes and allows the ignition sequence to proceed — when this capacitor weakens or fails, the inducer runs sluggishly or not at all, causing the pressure switch to remain open and locking out the entire heating cycle. Common symptoms include a furnace that attempts to start but shuts down before ignition, a pressure switch fault code, or a humming inducer motor that fails to spin up.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched MFD and voltage rating for Carrier draft inducer assembly | Factory tolerance ±3% | Designed for continuous-duty inducer motor operation | Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is manufactured to Carrier's exact electrical specifications. Generic alternatives frequently ship with ±10% MFD tolerances, causing inducer motors to run hot, overspeed, or underspeed — all of which shorten motor life and cause nuisance pressure switch trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling. Requires a nut driver, needle-nose pliers, and a multimeter to verify discharge. Always photograph wiring connections before removal. Capacitor is typically located on or near the inducer motor bracket inside the blower compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Ships same business day from our climate-controlled warehouse in original manufacturer packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered specifically for the Carrier \u003cstrong\u003eN6A48NG480198\u003c\/strong\u003e packaged gas unit draft inducer motor assembly. Verify your existing capacitor's MFD and voltage rating against your unit's data plate before ordering. If you need help confirming fitment, our HVAC parts specialists verify compatibility before every order — no guesswork required. \u003cstrong\u003eIn stock and ships today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909281337715,"sku":"CARRIE-N6A48NG480198-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909281370483,"sku":"CARRIE-N6A48NG480198-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_aaad160c-a5ff-4976-9979-f3c2bbe47c49.jpg?v=1782914120"},{"product_id":"carrier-n6a48ng480108-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG480108","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG480108\u003c\/h1\u003e\u003cp\u003eThis OEM capacitor is the factory-specified run capacitor included in the draft inducer motor assembly for the \u003cstrong\u003eCarrier N6A48NG480108\u003c\/strong\u003e packaged gas unit. The inducer motor capacitor provides the phase-shifted electrical charge required to start and run the combustion air inducer. When this capacitor fails, the inducer motor will hum without spinning, run sluggishly, or fail to prove draft pressure — resulting in a pressure switch lockout and a complete no-heat condition. This part corresponds to OEM assemblies \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e, allowing you to replace just the capacitor rather than the entire inducer motor assembly and save significantly on repair cost.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating per Carrier specification | Round or oval case (verify on data plate) | Designed for draft inducer motor duty cycle | Direct OEM replacement for assemblies 50HE400792 and HC30CL461\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are manufactured to exact factory MFD tolerance (±3%), ensuring proper inducer motor starting torque and run current. Generic alternatives often carry ±10% tolerance, which can cause motor overheating, premature winding failure, and nuisance pressure switch trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Requires shutting off power at the disconnect and confirming capacitor is fully discharged before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, insulated discharge resistor or screwdriver, and a multimeter to verify capacitance. Photograph all wiring before removal. Inducer compartment may require partial cabinet panel removal on this model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered as a direct OEM replacement for the \u003cstrong\u003eCarrier N6A48NG480108\u003c\/strong\u003e packaged gas unit inducer motor assembly. Cross-references OEM part numbers 50HE400792 and HC30CL461. Always confirm the MFD and voltage rating on the original capacitor or unit data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — order with confidence and get it shipped today.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909281993075,"sku":"CARRIE-N6A48NG480108-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909282025843,"sku":"CARRIE-N6A48NG480108-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_f4a4f3ed-daae-4955-b3bd-9adca3934d03.jpg?v=1782914118"},{"product_id":"carrier-n6a48ng480107-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for N6A48NG480107","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model N6A48NG480107\u003c\/h1\u003e\u003cp\u003eThis is the factory OEM capacitor matched to the draft inducer motor assembly on the \u003cstrong\u003eCarrier N6A48NG480107\u003c\/strong\u003e packaged gas unit. The inducer motor capacitor provides the start and run boost necessary for the draft inducer blower to reach operating speed before ignition begins. When this capacitor degrades or fails, the inducer motor may hum without spinning, run sluggishly, or fail to prove the flue — triggering a pressure switch lockout and preventing the furnace section from firing entirely. This part corresponds to OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor) and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor w\/ Capacitor), ensuring an exact factory-spec replacement for the capacitor component of that assembly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched MFD and voltage rating for Carrier N6A48NG480107 inducer motor | Factory ±3% tolerance | Round or oval case per OEM spec | Rated for continuous duty in high-heat flue environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are manufactured to exact factory tolerances. Aftermarket alternatives often carry ±10% MFD variance, which causes motor strain, reduces inducer longevity, and can produce nuisance pressure switch trips over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Turn off all power and gas before servicing. Discharge the capacitor using an insulated resistor before handling. Tools needed: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter with capacitance mode. Photograph all wiring connections before removal. Capacitor is located within the inducer motor housing compartment — allow unit to cool before access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders received before cutoff ship same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003eN6A48NG480107\u003c\/strong\u003e packaged gas unit draft inducer motor assembly. Cross-references OEM part numbers 50HE400792 and HC30CL461. Always verify the MFD and voltage rating on your existing capacitor or unit data plate before ordering to confirm fitment. Our HVAC parts specialists are available to verify compatibility before you buy — no guesswork required.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909282058611,"sku":"CARRIE-N6A48NG480107-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909282091379,"sku":"CARRIE-N6A48NG480107-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_97fe0dd9-40c4-4e7b-87b4-03e97c56bac0.jpg?v=1782914115"},{"product_id":"carrier-lc350tm400569-capacitor-1yf4q5","title":"OEM Carrier Draft Inducer Motor Capacitor for LC350TM400569","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor HC30CL461 for Model LC350TM400569\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor for the draft inducer motor assembly in the \u003cstrong\u003eCarrier LC350TM400569\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the starting and running torque needed to spin the inducer blower, which evacuates combustion gases before and during burner operation. When this capacitor fails, the inducer motor may hum without spinning, run intermittently, or fail to reach operating speed — triggering a pressure switch lockout and a no-heat condition. Replacing this capacitor is often a faster and more cost-effective repair than replacing the entire inducer motor assembly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched capacitance and voltage rating per Carrier part HC30CL461 | Designed specifically for draft inducer motor duty cycles | Factory-matched tolerance for reliable inducer performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is wound and rated to Carrier's exact factory specification. Off-brand substitutes frequently carry wider MFD tolerances, leading to inducer motor overheating, premature bearing failure, and repeat breakdowns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor before handling any terminals. Tools needed: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter with capacitance testing. Photograph all wiring connections before removal. Always confirm capacitor is fully discharged before touching terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship the same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Confirmed fit for Carrier model \u003cstrong\u003eLC350TM400569\u003c\/strong\u003e furnace using OEM part number \u003cstrong\u003eHC30CL461\u003c\/strong\u003e. Always verify the capacitance (MFD) and voltage rating on your existing capacitor's label against this part before installation. If you're unsure of fitment, our parts specialists can verify compatibility before you order — ships fast and arrives ready to install.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909297721715,"sku":"CARRIE-LC350TM400569-CAPACITOR-HC30CL461","price":548.75,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909297754483,"sku":"CARRIE-LC350TM400569-CAPACITOR-HC30CL461-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-draft-inducer-HC30CL461-1-1784769389148.jpg?v=1784769390"},{"product_id":"carrier-lc350tm400563-capacitor-1yf4q5","title":"OEM Carrier Draft Inducer Motor Capacitor for LC350TM400563","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC350TM400563\u003c\/h1\u003e\u003cp\u003eThis OEM run capacitor is the factory-specified replacement for the draft inducer motor on the \u003cstrong\u003eCarrier LC350TM400563\u003c\/strong\u003e furnace. The inducer motor capacitor provides the starting and running torque required to spin the draft inducer blower that vents combustion gases safely out of the heat exchanger. When this capacitor fails, the inducer motor will hum without turning, run sluggishly, or fail to reach proper speed — triggering the pressure switch and locking out ignition before any heat is produced.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM part number \u003cstrong\u003eHC30CL461\u003c\/strong\u003e | Factory-matched MFD and voltage rating | Designed specifically for Carrier draft inducer motor assemblies | ±3% tolerance for precision motor protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine OEM Carrier capacitor, not an aftermarket substitute. Generic capacitors often carry wider MFD tolerances (±10%), which can cause inducer motor overheating, premature bearing wear, and repeated pressure switch faults — OEM ensures the factory-engineered fit and lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter with capacitance setting. Photograph all wiring connections before disconnecting. The inducer motor capacitor is typically housed in or near the inducer motor housing in the upper section of the furnace cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. Orders placed by 3 PM EST ship the same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for the \u003cstrong\u003eCarrier LC350TM400563\u003c\/strong\u003e furnace draft inducer motor assembly (OEM part HC30CL461). Always verify the MFD and voltage rating on your existing capacitor's label or the inducer motor data plate before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you order if you have any questions. In stock and ready to ship today.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909298508147,"sku":"CARRIE-LC350TM400563-CAPACITOR-HC30CL461","price":600.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909298540915,"sku":"CARRIE-LC350TM400563-CAPACITOR-HC30CL461-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-motor-HC30CL461-1-1785344431979.jpg?v=1785344433"},{"product_id":"carrier-lc350tm400562-capacitor-1yf5hy","title":"OEM Carrier Draft Inducer Motor Capacitor for LC350TM400562","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC350TM400562\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor for the draft inducer motor on the \u003cstrong\u003eCarrier LC350TM400562\u003c\/strong\u003e furnace. The inducer motor capacitor provides the phase-shifted electrical charge needed to start and run the draft inducer — the blower that purges combustion gases before and during each heating cycle. When this capacitor degrades or fails, the inducer motor may hum without spinning, run sluggishly, or fail to prove pressure to the pressure switch, resulting in a no-heat lockout condition. OEM part numbers \u003cstrong\u003eHC30CK235\u003c\/strong\u003e and \u003cstrong\u003eHC30CR230\u003c\/strong\u003e both reference this draft inducer motor capacitor assembly for this platform.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating | Designed for draft inducer motor circuit | Round or oval case per OEM specification | ±5% tolerance for reliable motor start and run performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are wound and rated to Carrier's exact factory spec, ensuring correct phase timing and motor longevity. Generic capacitors with loose tolerances can cause premature inducer motor burnout, leading to a far costlier repair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling terminals. Tools needed: Phillips and flathead screwdrivers, 1\/4\" nut driver, needle-nose pliers, and a multimeter to confirm capacitance before reinstalling. Always photograph existing wiring before disconnecting leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for the \u003cstrong\u003eCarrier LC350TM400562\u003c\/strong\u003e furnace draft inducer motor circuit, cross-referencing OEM part numbers HC30CK235 and HC30CR230. Confirm your unit's data plate capacitor MFD and voltage rating match before ordering — our fitment team is available to verify compatibility prior to purchase. In stock and ready to ship today.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909298573683,"sku":"CARRIE-LC350TM400562-CAPACITOR-HC30CK235","price":15.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909298606451,"sku":"CARRIE-LC350TM400562-CAPACITOR-HC30CK235-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-P291-0403-1-1784842806634.jpg?v=1784842807"},{"product_id":"carrier-lc3-50lc400677-capacitor-1yf5hy","title":"OEM Carrier Draft Inducer Motor Capacitor for LC3:50LC400677","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC3:50LC400677\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor designed for the draft inducer motor assembly on the \u003cstrong\u003eCarrier LC3:50LC400677\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the phase-shifted electrical charge required to start and sustain the inducer blower — the component responsible for venting combustion gases before and during the heating cycle. When this capacitor fails, the inducer motor may hum without spinning, fail to reach operating speed, or prevent the pressure switch from closing, causing the furnace to lock out before ignition ever occurs. Replaces OEM part numbers \u003cstrong\u003eHC30CK235\u003c\/strong\u003e and \u003cstrong\u003eHC30CR230\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier LC3:50LC400677 draft inducer motor | Round or oval case per OEM spec | Tight ±5% tolerance for reliable motor performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is manufactured to exact Carrier factory tolerances. Generic alternatives often run outside ±10% MFD, which stresses inducer motor windings, accelerates bearing wear, and shortens overall motor life — leading to costly motor replacement rather than a simple capacitor swap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter for verification. Always photograph existing wiring before disconnecting. The capacitor is typically accessible after removing the furnace access panel and locating the inducer motor assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled parts warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered as a direct OEM replacement for Carrier model \u003cstrong\u003eLC3:50LC400677\u003c\/strong\u003e furnaces equipped with the HC30CK235 or HC30CR230 draft inducer motor assembly. Always verify the MFD and voltage rating on your existing capacitor or motor data tag before ordering to ensure an exact match. Our parts specialists are available to confirm fitment — order with confidence and get your furnace back online fast.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909300113779,"sku":"CARRIE-LC3:50LC400677——-CAPACITOR-HC30CK235","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909300146547,"sku":"CARRIE-LC3:50LC400677——-CAPACITOR-HC30CK235-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30CK235_fa849aad-b32c-443e-bb03-1773d173da29.jpg?v=1782914113"},{"product_id":"carrier-lc3-50lc400465-capacitor-1yf5hy","title":"OEM Carrier Draft Inducer Motor Capacitor for LC3:50LC400465","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC3:50LC400465\u003c\/h1\u003e\u003cp\u003eThis OEM run capacitor is the factory-specified replacement for the draft inducer motor assembly on the \u003cstrong\u003eCarrier LC3:50LC400465\u003c\/strong\u003e furnace. The inducer motor capacitor provides the phase-shifted current needed to start and sustain the draft inducer blower that purges combustion gases before and during each heating cycle. When this capacitor fails, the inducer motor will hum without spinning, fail to reach operating speed, or cause the pressure switch to never close — resulting in a no-heat lockout condition. Replaces OEM part numbers \u003cstrong\u003eHC30CK235\u003c\/strong\u003e and \u003cstrong\u003eHC30CR230\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier LC3:50LC400465 inducer motor | 370V\/440V rated round or oval case | OEM ±3% capacitance tolerance for precise motor performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are wound to exact factory specifications, ensuring correct starting torque for the inducer motor. Generic units with loose ±10% tolerance can cause the inducer to run slow, triggering nuisance pressure switch trips and premature motor failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge capacitor fully before handling any terminals. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter with capacitance setting. Photograph all wiring connections before disconnecting. Always shut off power at the disconnect and breaker before beginning work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before cutoff.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003eLC3:50LC400465\u003c\/strong\u003e furnace draft inducer motor assembly. This capacitor corresponds to OEM part numbers HC30CK235 and HC30CR230. Verify the MFD and voltage ratings on your existing capacitor or motor data plate before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — call or chat today. \u003cstrong\u003eIn stock and ships today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909301195123,"sku":"CARRIE-LC3:50LC400465——-CAPACITOR-HC30CK235","price":32.0,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909301227891,"sku":"CARRIE-LC3:50LC400465——-CAPACITOR-HC30CK235-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-P291-4053-1-1785344181015.jpg?v=1785344182"},{"product_id":"carrier-lc3-50he401232-capacitor-1yf5hy","title":"OEM Carrier Draft Inducer Motor Capacitor for LC3:50HE401232","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC3:50HE401232\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor paired with the draft inducer motor assembly on the \u003cstrong\u003eCarrier LC3:50HE401232\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the starting and running torque needed to spin the inducer blower that purges combustion gases before and during each heating cycle. When this capacitor degrades or fails, the inducer motor will hum without spinning, spin slowly, or fail to reach operating speed — triggering a pressure switch fault and locking out the furnace before ignition even begins. Replaces OEM part numbers \u003cstrong\u003eHC30CK235\u003c\/strong\u003e and \u003cstrong\u003eHC30CR230\u003c\/strong\u003e.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and 370V\/440V rating for the LC3:50HE401232 inducer motor circuit | Round or oval case (confirm with data plate) | Tight ±5% tolerance per OEM specification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This listing ships the genuine OEM Carrier capacitor (HC30CK235 \/ HC30CR230). OEM units are wound to exact factory MFD tolerance, ensuring full inducer RPM and reliable pressure switch closure. Off-brand capacitors can run outside tolerance, causing intermittent pressure switch faults and premature motor bearing wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Inducer motor capacitors are located inside the furnace cabinet near the inducer housing. Always shut off 120V power at the disconnect and discharge the capacitor before handling. Tools needed: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter (capacitance mode). Photograph all wiring terminals before disconnecting. If the full inducer motor assembly (HC30CK235 or HC30CR230) is being replaced, the capacitor is included — order the motor kit if the motor itself shows signs of bearing noise or overheating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. In-stock units ship same business day when ordered before 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the \u003cstrong\u003eCarrier LC3:50HE401232\u003c\/strong\u003e furnace draft inducer motor assembly. Cross-references OEM part numbers HC30CK235 and HC30CR230. Always verify the MFD rating and voltage stamped on your existing capacitor or motor data plate before ordering to confirm an exact match. Our parts specialists are available to verify fitment — contact us before you order if you have any questions.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909301358963,"sku":"CARRIE-LC3:50HE401232——-CAPACITOR-HC30CK235","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909301391731,"sku":"CARRIE-LC3:50HE401232——-CAPACITOR-HC30CK235-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30CK235_83fa0f89-d169-4db1-ba77-56a291f4768f.jpg?v=1782914106"},{"product_id":"carrier-lc350he401230-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for LC350HE401230","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC350HE401230\u003c\/h1\u003e\u003cp\u003eThis OEM-specified draft inducer motor capacitor is the factory-matched replacement for the \u003cstrong\u003eCarrier LC350HE401230\u003c\/strong\u003e furnace. The inducer motor capacitor provides the start and run current needed to spin the draft inducer blower at the beginning of each heating cycle. When this capacitor fails, the inducer motor may hum without starting, run sluggishly, or fail to reach operating speed — triggering the pressure switch and putting the furnace into a no-heat lockout condition. Replacing this capacitor is often the most cost-effective repair before replacing the entire inducer motor assembly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Draft inducer motor run capacitor | Factory-matched MFD and voltage rating | Designed for use with OEM assemblies 50HE400792 and HC30CL461 | Meets original factory tolerances ±3%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is manufactured to exact Carrier factory specifications, ensuring correct MFD tolerance and voltage rating for the inducer motor. Generic capacitors with loose ±10% tolerances can cause the inducer to underperform, leading to repeated pressure switch faults and premature motor failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor before handling. Tools needed: 1\/4\" nut driver, needle-nose pliers, multimeter (to verify discharge and confirm capacitance). Always photograph existing wiring before disconnecting terminals. Turn off power at the breaker and gas supply before beginning any repair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered for the Carrier \u003cstrong\u003eLC350HE401230\u003c\/strong\u003e furnace and paired with OEM inducer motor assemblies \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e. Verify your existing capacitor's MFD and voltage rating against your unit's data plate and wiring diagram before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — in stock and ready to ship today.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909301719411,"sku":"CARRIE-LC350HE401230-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909301752179,"sku":"CARRIE-LC350HE401230-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_aebfc97e-2839-4187-ac61-12d7fcb2d380.jpg?v=1782914091"},{"product_id":"carrier-lc350he401227-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for LC350HE401227","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC350HE401227\u003c\/h1\u003e\u003cp\u003eThis OEM draft inducer motor capacitor is the factory-specified replacement for the \u003cstrong\u003eCarrier LC350HE401227\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the starting and running torque required by the inducer blower motor to purge combustion gases and prove airflow before ignition begins. When this capacitor fails, the inducer motor may hum without spinning, run sluggishly, or fail to reach operating speed — causing the pressure switch to never close and leaving the furnace in a no-heat lockout condition. Compatible with OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Factory-matched MFD and voltage rating for Carrier LC350HE401227 inducer motor | Round or oval case (OEM spec) | Rated for continuous-duty furnace cycling | ±3% tolerance for precise motor protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is manufactured to exact Carrier factory specifications. Generic alternatives frequently fall outside acceptable MFD tolerance (±10% or worse), shortening inducer motor life and causing nuisance pressure switch trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Disconnect power and gas before servicing. The inducer assembly is typically located in the upper vestibule panel. Tools needed: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter. Always discharge the capacitor fully and photograph all wiring connections before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. Orders placed before cutoff ship the same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for the \u003cstrong\u003eCarrier LC350HE401227\u003c\/strong\u003e furnace as a direct OEM replacement for part numbers 50HE400792 and HC30CL461. Verify the MFD and voltage ratings printed on your existing capacitor against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — reach out before placing your order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909301817715,"sku":"CARRIE-LC350HE401227-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909301850483,"sku":"CARRIE-LC350HE401227-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_42443a8f-115b-4739-ad32-c9c37cd7ae21.jpg?v=1782914088"},{"product_id":"carrier-lc350he400812-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for LC350HE400812","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC350HE400812\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor paired with the draft inducer motor assembly on the \u003cstrong\u003eCarrier LC350HE400812\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the start and run torque required to spin the inducer blower — the component responsible for venting combustion gases before and during the heating cycle. When this capacitor weakens or fails, the inducer motor may hum without spinning, run sluggishly, or fail to reach operating speed, causing the pressure switch to never close and leaving the furnace in a pre-ignition lockout with no heat delivered to the home.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Designed for draft inducer motor use | Matches factory MFD and voltage rating for Carrier LC350HE400812 | Cylindrical run capacitor form factor | Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e (Draft Inducer Motor Assembly w\/ Capacitor) and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e (Draft Inducer Motor w\/ Capacitor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is manufactured to exact factory MFD tolerance (±5%), ensuring the inducer motor reaches correct RPM and does not overload windings. Generic alternatives commonly run outside tolerance, shortening motor life and triggering nuisance pressure switch faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Inducer motor capacitors are mounted within the inducer housing or nearby bracket. Tools needed: Phillips and flathead screwdriver, 1\/4\" nut driver, needle-nose pliers, multimeter (to verify discharge). Always shut off power at the breaker and discharge the capacitor fully before disconnecting terminals. Photograph wiring orientation before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Engineered specifically for the \u003cstrong\u003eCarrier LC350HE400812\u003c\/strong\u003e furnace draft inducer motor assembly. Cross-references OEM part numbers 50HE400792 and HC30CL461. Verify your existing capacitor's MFD and voltage rating against your unit's data plate before ordering to confirm fitment. Have questions about compatibility? Our HVAC parts specialists verify fitment before you place your order — same-day shipping available on all in-stock components.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909303095667,"sku":"CARRIE-LC350HE400812-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909303128435,"sku":"CARRIE-LC350HE400812-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_00d725a6-1dbc-4c86-b3e7-ef6146d2626d.jpg?v=1782914086"},{"product_id":"carrier-lc3-50he400811-capacitor-1yf5hy","title":"OEM Carrier Draft Inducer Motor Capacitor for LC3:50HE400811","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC3:50HE400811\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor designed for the draft inducer motor assembly on the \u003cstrong\u003eCarrier LC3:50HE400811\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the electrical starting and running boost required to spin the inducer blower at the correct speed and torque. Without a properly functioning capacitor, the inducer motor may fail to start, run sluggishly, or trip the pressure switch — resulting in a no-heat lockout condition. If your furnace is failing to ignite, showing pressure switch fault codes, or you can hear the inducer humming but not spinning freely, this capacitor is a common and cost-effective first repair to perform before replacing the full inducer motor assembly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched MFD and voltage rating | Factory-specified round or oval run capacitor | Engineered for continuous duty inducer motor operation | Replaces OEM part numbers \u003cstrong\u003eHC30CK235\u003c\/strong\u003e and \u003cstrong\u003eHC30CR230\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM capacitors are wound to exact factory tolerances (±5% or better), ensuring the inducer motor reaches proper RPM for reliable draft proving. Off-brand capacitors with loose tolerances can cause marginal operation, nuisance pressure switch lockouts, and premature motor bearing wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Disconnect power at the breaker and verify voltage is absent before beginning. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers, multimeter (to verify capacitor is fully discharged). Photograph all wiring connections before removing the old capacitor. Match polarity and terminal labeling carefully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship the same business day from our climate-controlled warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e This capacitor is designed to fit the \u003cstrong\u003eCarrier LC3:50HE400811\u003c\/strong\u003e furnace draft inducer motor assembly, replacing OEM part numbers HC30CK235 and HC30CR230. Always confirm the MFD and voltage rating stamped on your existing capacitor or inducer motor label before ordering to ensure an exact match. Not sure if this is the right part? Contact our HVAC parts specialists — we verify fitment before you buy.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909303685491,"sku":"CARRIE-LC3:50HE400811——-CAPACITOR-HC30CK235","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909303718259,"sku":"CARRIE-LC3:50HE400811——-CAPACITOR-HC30CK235-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30CK235_a4b42ba9-72ec-4d43-a02e-5e9815e14b1b.jpg?v=1782914104"},{"product_id":"carrier-lc350he400803-capacitor-j89nd1","title":"OEM Carrier Draft Inducer Motor Capacitor for LC350HE400803","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC350HE400803\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor included with the draft inducer motor assembly on the \u003cstrong\u003eCarrier LC350HE400803\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the phase-shifted electrical charge required to start and run the inducer blower that exhausts combustion gases before and during the heating cycle. When this capacitor fails, the inducer motor will hum without spinning, run sluggishly, or fail to start entirely — causing the furnace to lock out on a pressure switch fault before ignition is ever attempted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e Run capacitor matched to Carrier draft inducer motor assembly | Factory-rated voltage and MFD tolerance | Replaces OEM part numbers \u003cstrong\u003e50HE400792\u003c\/strong\u003e and \u003cstrong\u003eHC30CL461\u003c\/strong\u003e | Round or oval case depending on assembly revision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor is wound to exact factory MFD and voltage tolerances (±3%), ensuring full inducer motor torque and longevity. Aftermarket capacitors with ±10% tolerance can cause chronic inducer startup failures and shorten motor bearing life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 3\/5\u003c\/strong\u003e — Inducer motor capacitor replacement requires accessing the inducer housing, typically mounted on the top or side of the heat exchanger box. Tools needed: nut driver set, needle-nose pliers, multimeter (to verify discharge and confirm MFD). Always discharge the capacitor across its terminals before handling, and photograph all wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the \u003cstrong\u003eCarrier LC350HE400803\u003c\/strong\u003e furnace draft inducer motor assembly. Cross-references OEM part numbers 50HE400792 and HC30CL461. Always verify the MFD and voltage rating printed on your existing capacitor or inducer motor data label before ordering to confirm fitment. Our parts specialists are available to verify compatibility before you purchase — same-day shipping available on in-stock orders.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909304406387,"sku":"CARRIE-LC350HE400803-CAPACITOR-50HE400792","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909304439155,"sku":"CARRIE-LC350HE400803-CAPACITOR-50HE400792-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-50HE400792_c25868b3-f9f6-499b-bdc4-3ce282ef3197.jpg?v=1782914083"},{"product_id":"carrier-lc3-50he400802-capacitor-1yf5hy","title":"OEM Carrier Draft Inducer Motor Capacitor for LC3:50HE400802","description":"\u003ch1\u003eOEM Carrier Draft Inducer Motor Capacitor for Model LC3:50HE400802\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM run capacitor for the draft inducer motor assembly on the \u003cstrong\u003eCarrier LC3:50HE400802\u003c\/strong\u003e furnace. The draft inducer motor capacitor provides the phase-shifting electrical charge required to start and sustain the inducer blower, which evacuates combustion gases before and during each heating cycle. When this capacitor degrades or fails, the inducer motor may hum without spinning, run sluggishly, or fail to prove combustion airflow — triggering a pressure switch fault and locking out the entire furnace. Compatible with OEM part numbers \u003cstrong\u003eHC30CK235\u003c\/strong\u003e and \u003cstrong\u003eHC30CR230\u003c\/strong\u003e, both listed by Carrier as \u003cem\u003eDraft Inducer Motor w\/ Capacitor\u003c\/em\u003e assemblies; this capacitor is the standalone replacement component within that assembly.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e OEM-matched MFD rating and 370V\/440V voltage rating for the LC3:50HE400802 inducer motor | Round or oval case depending on production run | Factory ±5% tolerance for reliable motor starting | Replaces capacitor component within HC30CK235 and HC30CR230 assemblies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM capacitor meets Carrier's exact factory tolerance specifications. Aftermarket capacitors frequently ship with ±10% MFD variance, causing inducer motor overheating, premature winding failure, and nuisance pressure switch trips — costing far more in callbacks and motor replacements than the price difference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Discharge the capacitor fully before handling any terminals. Recommended tools: 1\/4\" and 5\/16\" nut drivers, needle-nose pliers, multimeter (capacitance mode). Photograph all wiring connections before disconnecting. Turn off power at the disconnect and breaker before beginning work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; Shipping:\u003c\/strong\u003e Backed by a 1-year OEM factory warranty against defects. In stock and ships same business day from our warehouse when ordered before 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility \u0026amp; Fitment:\u003c\/strong\u003e Engineered for the \u003cstrong\u003eCarrier LC3:50HE400802\u003c\/strong\u003e furnace draft inducer motor circuit. Always verify the MFD rating and voltage printed on your existing capacitor or inducer motor data label before ordering. Cross-references OEM part numbers HC30CK235 and HC30CR230. Not sure if this is the right part? Our HVAC parts specialists verify fitment before you buy — contact us before placing your order.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62909304504691,"sku":"CARRIE-LC3:50HE400802——-CAPACITOR-HC30CK235","price":56.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62909304537459,"sku":"CARRIE-LC3:50HE400802——-CAPACITOR-HC30CK235-GEN","price":49.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-single-HC30CK235_d5100c01-c4d0-49cf-a5db-9f42b08cc9c2.jpg?v=1782914102"}],"url":"https:\/\/nationalhvacparts.com\/collections\/draft-inducer-motors.oembed?page=3","provider":"National HVAC Parts","version":"1.0","type":"link"}